Viewing Study NCT05873335


Ignite Creation Date: 2025-12-24 @ 10:23 PM
Ignite Modification Date: 2026-04-11 @ 8:55 AM
Study NCT ID: NCT05873335
Status: COMPLETED
Last Update Posted: 2024-12-12
First Post: 2023-05-04
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: In Vivo Pulse Oximeter Validation Study
Sponsor:
Organization:

Raw JSON

{'hasResults': True, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24', 'submissionTracking': {'firstMcpInfo': {'postDateStruct': {'date': '2024-10-30', 'type': 'ACTUAL'}}}}, 'conditionBrowseModule': {'meshes': [{'id': 'D000860', 'term': 'Hypoxia'}], 'ancestors': [{'id': 'D012818', 'term': 'Signs and Symptoms, Respiratory'}, {'id': 'D012816', 'term': 'Signs and Symptoms'}, {'id': 'D013568', 'term': 'Pathological Conditions, Signs and Symptoms'}]}, 'interventionBrowseModule': {'meshes': [{'id': 'D000388', 'term': 'Air'}, {'id': 'D002245', 'term': 'Carbon Dioxide'}], 'ancestors': [{'id': 'D001272', 'term': 'Atmosphere'}, {'id': 'D004777', 'term': 'Environment'}, {'id': 'D055669', 'term': 'Ecological and Environmental Phenomena'}, {'id': 'D001686', 'term': 'Biological Phenomena'}, {'id': 'D008685', 'term': 'Meteorological Concepts'}, {'id': 'D004778', 'term': 'Environment and Public Health'}, {'id': 'D017554', 'term': 'Carbon Compounds, Inorganic'}, {'id': 'D007287', 'term': 'Inorganic Chemicals'}, {'id': 'D005740', 'term': 'Gases'}, {'id': 'D010087', 'term': 'Oxides'}, {'id': 'D017601', 'term': 'Oxygen Compounds'}]}}, 'resultsSection': {'moreInfoModule': {'pointOfContact': {'email': 'edouard.carton@gabismartcare.com', 'phone': '472537844', 'title': 'Edouard Carton', 'organization': 'Gabi SmartCare'}, 'certainAgreement': {'piSponsorEmployee': False, 'restrictiveAgreement': False}}, 'adverseEventsModule': {'timeFrame': '2 hours', 'description': 'All healthy participants', 'eventGroups': [{'id': 'EG000', 'title': 'Healthy Adults', 'description': 'Healthy adults\n\nMixtures of nitrogen, air, and carbon dioxide: Hypoxia was induced to different and stable levels of oxyhemoglobin saturation (between 70-100%) by having subjects breathe mixtures of nitrogen, air, and carbon dioxide controlled by the study physician by adjusting gas flows with valves according to breath-by-breath estimates of oxygen saturation calculated from end-tidal PO2 and PCO2 displayed on a screen using LabVIEW 2015. 2 Gabi Band devices were placed on the subject (one on each arm). It was expected that the Accuracy Root Mean Square (ARMS) performance of the oximetry system would meet the required specification of ARMS of 3.5% or less.', 'otherNumAtRisk': 12, 'deathsNumAtRisk': 12, 'otherNumAffected': 0, 'seriousNumAtRisk': 12, 'deathsNumAffected': 0, 'seriousNumAffected': 0}], 'frequencyThreshold': '0'}, 'outcomeMeasuresModule': {'outcomeMeasures': [{'type': 'PRIMARY', 'title': 'Measure of Accuracy (ARMS [%])', 'denoms': [{'units': 'Participants', 'counts': [{'value': '12', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Healthy Adults', 'description': 'Healthy adults\n\nMixtures of nitrogen, air, and carbon dioxide: Hypoxia was induced to different and stable levels of oxyhemoglobin saturation (between 70-100%) by having subjects breathe mixtures of nitrogen, air, and carbon dioxide controlled by the study physician by adjusting gas flows with valves according to breath-by-breath estimates of oxygen saturation calculated from end-tidal PO2 and PCO2 displayed on a screen using LabVIEW 2015'}], 'classes': [{'categories': [{'measurements': [{'value': '2.95', 'groupId': 'OG000'}]}]}], 'paramType': 'NUMBER', 'timeFrame': '1 hour', 'description': 'Arms, given in percentage or rms error, is the calculation of root mean square between SpO2 values from the subject device and the SaO2 from the Hemoximeter. It is a way of averaging the absolute values of errors over the full measurement range and is a similar measurmeent to a "rms error". It indicates how far (accurate) the provided value is from the reference used.', 'unitOfMeasure': 'Percentage', 'reportingStatus': 'POSTED'}]}, 'participantFlowModule': {'groups': [{'id': 'FG000', 'title': 'Healthy Adults', 'description': 'Healthy adults\n\nMixtures of nitrogen, air, and carbon dioxide: Hypoxia was induced to different and stable levels of oxyhemoglobin saturation (between 70-100%) by having subjects breathe mixtures of nitrogen, air, and carbon dioxide controlled by the study physician by adjusting gas flows with valves according to breath-by-breath estimates of oxygen saturation calculated from end-tidal PO2 and PCO2 displayed on a screen using LabVIEW 2015. 2 Gabi Band devices were placed on the subject (one on each arm). It was expected that the Accuracy Root Mean Square (ARMS) performance of the oximetry system would meet the required specification of ARMS of 3.5% or less.'}], 'periods': [{'title': 'Overall Study', 'milestones': [{'type': 'STARTED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '12'}]}, {'type': 'COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '12'}]}, {'type': 'NOT COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '0'}]}]}]}, 'baselineCharacteristicsModule': {'denoms': [{'units': 'Participants', 'counts': [{'value': '12', 'groupId': 'BG000'}]}], 'groups': [{'id': 'BG000', 'title': 'Healthy Adults', 'description': 'Healthy adults\n\nMixtures of nitrogen, air, and carbon dioxide: Hypoxia was induced to different and stable levels of oxyhemoglobin saturation (between 70-100%) by having subjects breathe mixtures of nitrogen, air, and carbon dioxide controlled by the study physician by adjusting gas flows with valves according to breath-by-breath estimates of oxygen saturation calculated from end-tidal PO2 and PCO2 displayed on a screen using LabVIEW 2015. 2 Gabi Band devices were placed on the subject (one on each arm). It was expected that the Accuracy Root Mean Square (ARMS) performance of the oximetry system would meet the required specification of ARMS of 3.5% or less.'}], 'measures': [{'title': 'Age, Categorical', 'classes': [{'categories': [{'title': '<=18 years', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Between 18 and 65 years', 'measurements': [{'value': '12', 'groupId': 'BG000'}]}, {'title': '>=65 years', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Age, Continuous', 'classes': [{'categories': [{'measurements': [{'value': '25.25', 'groupId': 'BG000', 'lowerLimit': '22', 'upperLimit': '28'}]}]}], 'paramType': 'MEAN', 'unitOfMeasure': 'years', 'dispersionType': 'FULL_RANGE'}, {'title': 'Sex: Female, Male', 'classes': [{'categories': [{'title': 'Female', 'measurements': [{'value': '8', 'groupId': 'BG000'}]}, {'title': 'Male', 'measurements': [{'value': '4', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Race (NIH/OMB)', 'classes': [{'categories': [{'title': 'American Indian or Alaska Native', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Asian', 'measurements': [{'value': '5', 'groupId': 'BG000'}]}, {'title': 'Native Hawaiian or Other Pacific Islander', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Black or African American', 'measurements': [{'value': '2', 'groupId': 'BG000'}]}, {'title': 'White', 'measurements': [{'value': '3', 'groupId': 'BG000'}]}, {'title': 'More than one race', 'measurements': [{'value': '1', 'groupId': 'BG000'}]}, {'title': 'Unknown or Not Reported', 'measurements': [{'value': '1', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Region of Enrollment', 'classes': [{'title': 'United States', 'categories': [{'measurements': [{'value': '12', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}], 'populationDescription': '12 healthy adults in total, each wearing 1 Gabi Band device on each arm'}}, 'documentSection': {'largeDocumentModule': {'largeDocs': [{'date': '2023-02-02', 'size': 39991, 'label': 'Study Protocol and Statistical Analysis Plan', 'hasIcf': False, 'hasSap': True, 'filename': 'Prot_SAP_002.pdf', 'typeAbbrev': 'Prot_SAP', 'uploadDate': '2024-12-10T04:11', 'hasProtocol': True}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'OTHER', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 12}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2023-02-28', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2024-12', 'completionDateStruct': {'date': '2023-03-01', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2024-12-10', 'studyFirstSubmitDate': '2023-05-04', 'resultsFirstSubmitDate': '2024-10-03', 'studyFirstSubmitQcDate': '2023-05-15', 'lastUpdatePostDateStruct': {'date': '2024-12-12', 'type': 'ACTUAL'}, 'resultsFirstSubmitQcDate': '2024-12-10', 'studyFirstPostDateStruct': {'date': '2023-05-24', 'type': 'ACTUAL'}, 'resultsFirstPostDateStruct': {'date': '2024-12-12', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2023-03-01', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Measure of Accuracy (ARMS [%])', 'timeFrame': '1 hour', 'description': 'Arms, given in percentage or rms error, is the calculation of root mean square between SpO2 values from the subject device and the SaO2 from the Hemoximeter. It is a way of averaging the absolute values of errors over the full measurement range and is a similar measurmeent to a "rms error". It indicates how far (accurate) the provided value is from the reference used.'}]}, 'oversightModule': {'isUsExport': False, 'oversightHasDmc': False, 'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': True}, 'conditionsModule': {'conditions': ['Hypoxia']}, 'descriptionModule': {'briefSummary': 'The goal of this clinical trial is to compare values of SpO2 provided by the DUT and the SaO2 used as a reference in healthy adults. The main question it aims to answer is: what is the accuracy of the subject device compared to the 510(k)-cleared reference device\n\nA radial arterial cannula was placed in the wrist of each subject for arterial blood sampling and a subject device was placed on each arm of the patients. Then, hypoxia was induced to different stable levels of oxyhemoglobin saturation between 70-100% by having subjects breathe mixtures of nitrogen, air, and carbon dioxide controlled by the study physician. Values of SpO2 and SaO2 were then compared to provide a root mean square error and conclude on the subject device accuracy.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT'], 'maximumAge': '50 Years', 'minimumAge': '21 Years', 'healthyVolunteers': True, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Healthy adult\n* Normal hemoglobin levels (Hemoglobin \\> 10 g/dL)\n\nExclusion Criteria:\n\n* Systemic illness\n* Obesity'}, 'identificationModule': {'nctId': 'NCT05873335', 'briefTitle': 'In Vivo Pulse Oximeter Validation Study', 'organization': {'class': 'INDUSTRY', 'fullName': 'Gabi SmartCare'}, 'officialTitle': 'In Vivo Testing for SpO2 Accuracy on Healthy Adults Under Laboratory Conditions', 'orgStudyIdInfo': {'id': 'SpO2_3'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Healthy Adults', 'description': 'Healthy adults', 'interventionNames': ['Combination Product: Mixtures of nitrogen, air, and carbon dioxide']}], 'interventions': [{'name': 'Mixtures of nitrogen, air, and carbon dioxide', 'type': 'COMBINATION_PRODUCT', 'otherNames': ['Radial arterial cannula'], 'description': 'Hypoxia was induced to different and stable levels of oxyhemoglobin saturation (between 70-100%) by having subjects breathe mixtures of nitrogen, air, and carbon dioxide controlled by the study physician by adjusting gas flows with valves according to breath-by-breath estimates of oxygen saturation calculated from end-tidal PO2 and PCO2 displayed on a screen using LabVIEW 2015', 'armGroupLabels': ['Healthy Adults']}]}, 'contactsLocationsModule': {'locations': [{'zip': '94143', 'city': 'San Francisco', 'state': 'California', 'country': 'United States', 'facility': 'Hypoxia Research Laboratory', 'geoPoint': {'lat': 37.77493, 'lon': -122.41942}}], 'overallOfficials': [{'name': 'Philip E Bickler, M.D., PhD.', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'University of California, San Francisco'}]}, 'ipdSharingStatementModule': {'ipdSharing': 'NO'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Gabi SmartCare', 'class': 'INDUSTRY'}, 'responsibleParty': {'type': 'SPONSOR'}}}}