Viewing Study NCT01670292


Ignite Creation Date: 2025-12-24 @ 3:50 PM
Ignite Modification Date: 2026-04-17 @ 2:28 AM
Study NCT ID: NCT01670292
Status: COMPLETED
Last Update Posted: 2017-12-05
First Post: 2012-08-02
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: Patient Response to Spinal Manipulation
Sponsor:
Organization:

Raw JSON

{'hasResults': True, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D017116', 'term': 'Low Back Pain'}], 'ancestors': [{'id': 'D001416', 'term': 'Back Pain'}, {'id': 'D010146', 'term': 'Pain'}, {'id': 'D009461', 'term': 'Neurologic Manifestations'}, {'id': 'D012816', 'term': 'Signs and Symptoms'}, {'id': 'D013568', 'term': 'Pathological Conditions, Signs and Symptoms'}]}}, 'resultsSection': {'moreInfoModule': {'pointOfContact': {'email': 'ting.xia@palmer.edu', 'phone': '563-884-5161', 'title': 'Dr. Ting Xia', 'organization': 'Palmer Center for Chiropractic Research'}, 'certainAgreement': {'piSponsorEmployee': True}}, 'adverseEventsModule': {'timeFrame': '6 weeks', 'description': 'Any untoward medical occurrence that may present itself during the conduct of the study which may or may not have a causal relationship with the study procedures.\n\n\\*The total number of AEs may exceed the total # of people affected because some people experienced multiple AEs.', 'eventGroups': [{'id': 'EG000', 'title': 'Experimental: HVLA-SM*', 'description': 'Experimental High Velocity Low Amplitude Spinal Manipulation\n\nHVLA-SM: High Velocity Low Amplitude Spinal Manipulation', 'otherNumAtRisk': 82, 'deathsNumAtRisk': 82, 'otherNumAffected': 74, 'seriousNumAtRisk': 82, 'deathsNumAffected': 0, 'seriousNumAffected': 0}], 'otherEvents': [{'term': 'Neck pain/stiffness', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 2}], 'organSystem': 'Musculoskeletal and connective tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Low back pain/stiffness', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 29}], 'organSystem': 'Musculoskeletal and connective tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Neck and back pain/stiffness', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 2}], 'organSystem': 'Musculoskeletal and connective tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Headache and neck/back pain', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 2}], 'organSystem': 'Musculoskeletal and connective tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Back pain and extremity pain/stiffness', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 20}], 'organSystem': 'Musculoskeletal and connective tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Thoracic and low back pain/stiffness', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 5}], 'organSystem': 'Musculoskeletal and connective tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Neck, back and extremity pain/stiffness', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 4}], 'organSystem': 'Musculoskeletal and connective tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Back and extremity pain/stiffness', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 2}], 'organSystem': 'Musculoskeletal and connective tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Neck and extremity pain/stiffness', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'Musculoskeletal and connective tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Pain/stiffness in the extremities', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'Musculoskeletal and connective tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Lower/extremity pain/stiffness', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 2}], 'organSystem': 'Musculoskeletal and connective tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Neck and back pain and extremity pain and headache', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'Musculoskeletal and connective tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Back pain/stiffness and numbness/tingling', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'Musculoskeletal and connective tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Back pain and extremity pain and numbness/tingling', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'Musculoskeletal and connective tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Upper respiratory infection', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 5}], 'organSystem': 'General disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Sinus congestion/upper respiratory symptoms/allergy', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 5}], 'organSystem': 'General disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Insect bite', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'General disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Hypertension', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'General disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Gastrointestinal symptoms', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'General disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Hemorrhoids', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'General disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Nausea and tooth/facial pain and sinus congestion', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'General disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Nausea and back pain/stiffness', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'General disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Dental caries', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'General disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Asthma and lower respiratory infection', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'General disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Upper respiratory infection and allergy', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'General disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Hemorrhoids and nasal congestion', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 1}], 'organSystem': 'General disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Laceration', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 2}], 'organSystem': 'Skin and subcutaneous tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Blister', 'stats': [{'groupId': 'EG000', 'numAtRisk': 82, 'numAffected': 2}], 'organSystem': 'Skin and subcutaneous tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}], 'frequencyThreshold': '0'}, 'outcomeMeasuresModule': {'outcomeMeasures': [{'type': 'PRIMARY', 'title': 'Patient-Centered Outcome Measurement Mean Change After 6 Weeks (VAS, RMDQ)', 'denoms': [{'units': 'Participants', 'counts': [{'value': '82', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Experimental: HVLA-SM', 'description': 'Experimental High Velocity Low Amplitude Spinal Manipulation\n\nHVLA-SM: High Velocity Low Amplitude Spinal Manipulation'}], 'classes': [{'title': 'Mean Reduction in VAS score (mm)', 'categories': [{'measurements': [{'value': '20.1', 'groupId': 'OG000', 'lowerLimit': '14.1', 'upperLimit': '26.1'}]}]}, {'title': 'Mean Reduction in RMDQ score', 'categories': [{'measurements': [{'value': '4.8', 'groupId': 'OG000', 'lowerLimit': '3.7', 'upperLimit': '5.8'}]}]}], 'paramType': 'MEAN', 'timeFrame': 'Baseline to 6 weeks', 'description': 'VAS - Visual Analog Scale - Scale: 0-100 mm (anchors: 0 mm = No Pain, 100 mm = Worst Imaginable Pain). VAS Interpretation: A higher score indicates greater pain intensity. In this study, improvement of 30% from the baseline value was considered clinically significant.\n\nRMDQ - Roland Morris disability questionnaire - Scale: 0 (no disability) to 24 (maximum disability). RMDQ Interpretation: Greater levels of disability are reflected by higher scores. In this study, improvement of 30% from the baseline value was considered clinically significant.', 'unitOfMeasure': 'units on a scale (see description above)', 'dispersionType': '95% Confidence Interval', 'reportingStatus': 'POSTED', 'populationDescription': '82 and 68 participants completed at baseline and after 6 weeks, respectively. Data from all participants (n=82) were used in statistical analysis. The reported data represents the mean change from baseline to week 6.'}, {'type': 'PRIMARY', 'title': 'Lumbar-spine Stiffness (LSS)', 'denoms': [{'units': 'Participants', 'counts': [{'value': '82', 'groupId': 'OG000'}, {'value': '71', 'groupId': 'OG001'}, {'value': '68', 'groupId': 'OG002'}]}], 'groups': [{'id': 'OG000', 'title': 'HVLA-SM at Baseline', 'description': 'Results at Baseline\n\nExperimental High Velocity Low Amplitude Spinal Manipulation\n\nHVLA-SM: High Velocity Low Amplitude Spinal Manipulation'}, {'id': 'OG001', 'title': 'HVLA-SM After 2 Weeks', 'description': 'There is only one group/arm, this is the data for the same group of participants after two weeks.'}, {'id': 'OG002', 'title': 'HVLA-SM After 6 Weeks', 'description': 'There is only one group/arm, this is the data for the same group of participants after six weeks.'}], 'classes': [{'title': 'LSS - Palpatory - GS (N/mm) at L3', 'categories': [{'measurements': [{'value': '4.8', 'spread': '1.8', 'groupId': 'OG000'}, {'value': '4.3', 'spread': '1.8', 'groupId': 'OG001'}, {'value': '4.2', 'spread': '1.3', 'groupId': 'OG002'}]}]}, {'title': 'LSS - Hand-held - GS (N/mm) at L3', 'categories': [{'measurements': [{'value': '7.7', 'spread': '2.1', 'groupId': 'OG000'}, {'value': '7.5', 'spread': '1.8', 'groupId': 'OG001'}, {'value': '7.6', 'spread': '2.2', 'groupId': 'OG002'}]}]}, {'title': 'LSS - Automated - GS (N/mm) at Ant', 'categories': [{'measurements': [{'value': '5.2', 'spread': '1.5', 'groupId': 'OG000'}, {'value': '5.3', 'spread': '1.4', 'groupId': 'OG001'}, {'value': '5.3', 'spread': '1.5', 'groupId': 'OG002'}]}]}, {'title': 'LSS - Palpatory - GSV (N/mm)', 'categories': [{'measurements': [{'value': '2.3', 'spread': '1.5', 'groupId': 'OG000'}, {'value': '2.0', 'spread': '1.1', 'groupId': 'OG001'}, {'value': '1.9', 'spread': '1.1', 'groupId': 'OG002'}]}]}, {'title': 'LSS - Hand-held - GSV (N/mm)', 'categories': [{'measurements': [{'value': '2.3', 'spread': '1.3', 'groupId': 'OG000'}, {'value': '2.1', 'spread': '1.1', 'groupId': 'OG001'}, {'value': '2.1', 'spread': '1.3', 'groupId': 'OG002'}]}]}], 'paramType': 'MEAN', 'timeFrame': 'Baseline, 2 weeks, 6 weeks', 'description': 'LSS\\* contains 5 variables: global stiffness (GS, unit: Newton/mm) at L3 from 1) hand palpation 2) a hand-held device \\& 3) an automated indenter device; global stiffness variation (GSV, unit: Newton/mm) between GS from L1 to L5 from 4) hand palpation \\& 5) a hand-held device.\n\n\\*LSS Interpretation: The values of the outcome depend on testing procedure, instruction to participants, and equipment. Currently there is no consensus regarding what value is high than normal, normal, lower than normal.', 'unitOfMeasure': 'N/mm', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'populationDescription': '82, 71 and 68 participants completed at baseline, after 2 weeks and after 6 weeks, respectively. The number of observations at each of the 3 time points for individual measures is equal to or lower than these numbers due to missing data.'}, {'type': 'PRIMARY', 'title': 'Lumbar-spine Stiffness (LSS) - Normalized Global Stiffness Variation', 'denoms': [{'units': 'Participants', 'counts': [{'value': '82', 'groupId': 'OG000'}, {'value': '71', 'groupId': 'OG001'}, {'value': '68', 'groupId': 'OG002'}]}], 'groups': [{'id': 'OG000', 'title': 'HVLA-SM at Baseline', 'description': 'Results at Baseline\n\nExperimental High Velocity Low Amplitude Spinal Manipulation\n\nHVLA-SM: High Velocity Low Amplitude Spinal Manipulation'}, {'id': 'OG001', 'title': 'HVLA-SM After 2 Weeks', 'description': 'There is only one group/arm, this is the data for the same group of participants after two weeks.'}, {'id': 'OG002', 'title': 'HVLA-SM After 6 Weeks', 'description': 'There is only one group/arm, this is the data for the same group of participants after six weeks.'}], 'classes': [{'title': 'LSS - Palpatory - nGSV', 'categories': [{'measurements': [{'value': '0.5', 'spread': '0.2', 'groupId': 'OG000'}, {'value': '0.5', 'spread': '0.2', 'groupId': 'OG001'}, {'value': '0.5', 'spread': '0.2', 'groupId': 'OG002'}]}]}, {'title': 'LSS - Hand-held - nGSV', 'categories': [{'measurements': [{'value': '0.3', 'spread': '0.1', 'groupId': 'OG000'}, {'value': '0.3', 'spread': '0.1', 'groupId': 'OG001'}, {'value': '0.3', 'spread': '0.1', 'groupId': 'OG002'}]}]}], 'paramType': 'MEAN', 'timeFrame': 'Baseline, 2 weeks, 6 weeks', 'description': 'LSS contains 2 variables: Palpatory and Handheld device - normalized global stiffness variation (nGSV, unitless).\n\nLSS Interpretation: The values of the outcome depend on testing procedure, instruction to participants, and equipment. Currently there is no consensus regarding what value is higher than normal, normal, lower than normal.', 'unitOfMeasure': 'unitless', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED'}, {'type': 'PRIMARY', 'title': 'Flexion-Relaxation Ratio (FRR)', 'denoms': [{'units': 'Participants', 'counts': [{'value': '82', 'groupId': 'OG000'}, {'value': '71', 'groupId': 'OG001'}, {'value': '68', 'groupId': 'OG002'}]}], 'groups': [{'id': 'OG000', 'title': 'HVLA-SM at Baseline', 'description': 'Results at Baseline\n\nExperimental High Velocity Low Amplitude Spinal Manipulation\n\nHVLA-SM: High Velocity Low Amplitude Spinal Manipulation'}, {'id': 'OG001', 'title': 'HVLA-SM After 2 Weeks', 'description': 'There is only one group/arm, this is the data for the same group of participants after two weeks.'}, {'id': 'OG002', 'title': 'HVLA-SM After 6 Weeks', 'description': 'There is only one group/arm, this is the data for the same group of participants after six weeks.'}], 'classes': [{'title': 'Flexion FRR', 'categories': [{'measurements': [{'value': '4.7', 'spread': '3.7', 'groupId': 'OG000'}, {'value': '5.8', 'spread': '5.4', 'groupId': 'OG001'}, {'value': '5.5', 'spread': '5.6', 'groupId': 'OG002'}]}]}, {'title': 'Extension FRR', 'categories': [{'measurements': [{'value': '9.2', 'spread': '9.5', 'groupId': 'OG000'}, {'value': '10.4', 'spread': '11.6', 'groupId': 'OG001'}, {'value': '9.4', 'spread': '10.5', 'groupId': 'OG002'}]}]}, {'title': 'Asymmetry in flexion FRR', 'categories': [{'measurements': [{'value': '1.5', 'spread': '0.5', 'groupId': 'OG000'}, {'value': '1.4', 'spread': '0.5', 'groupId': 'OG001'}, {'value': '1.4', 'spread': '0.4', 'groupId': 'OG002'}]}]}, {'title': 'Asymmetry in extension FRR', 'categories': [{'measurements': [{'value': '1.4', 'spread': '0.7', 'groupId': 'OG000'}, {'value': '1.4', 'spread': '0.4', 'groupId': 'OG001'}, {'value': '1.4', 'spread': '0.5', 'groupId': 'OG002'}]}]}], 'paramType': 'MEAN', 'timeFrame': 'Baseline, 2 weeks, 6 weeks', 'description': 'FRR contains 4 variables, which are the average right and left back muscle FRR obtained using 1) maximum EMG during flexion, and 2) maximum EMG during extension to normalize EMG during full flexion; and asymmetry between the right and left back muscle FRRs using 3) maximum EMG during flexion, and 4) maximum EMG during extension to normalize EMG during full flexion\n\nFRR Interpretation: The values of the outcome depend on testing procedure, instruction to participants, and equipment. Currently there is no consensus regarding what value is high than normal, normal, lower than normal.', 'unitOfMeasure': 'ratio', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED'}, {'type': 'SECONDARY', 'title': 'Kinetic Measure - Spinal Segment Load (SSL) Force', 'denoms': [{'units': 'Participants', 'counts': [{'value': '68', 'groupId': 'OG000'}, {'value': '68', 'groupId': 'OG001'}, {'value': '68', 'groupId': 'OG002'}, {'value': '68', 'groupId': 'OG003'}]}, {'units': 'Spinal Manipulations', 'counts': [{'value': '575', 'groupId': 'OG000'}, {'value': '575', 'groupId': 'OG001'}, {'value': '575', 'groupId': 'OG002'}, {'value': '575', 'groupId': 'OG003'}]}], 'groups': [{'id': 'OG000', 'title': 'Anterior-Posterior (X)', 'description': 'All participants are in this group, this simply defines the mean force/moment in the X direction.'}, {'id': 'OG001', 'title': 'Side-to-Side (Y)', 'description': 'All participants are in this group, this simply defines the mean force/moment in the Y direction.'}, {'id': 'OG002', 'title': 'Head-to-Toe (Z)', 'description': 'All participants are in this group, this simply defines the mean force/moment in the Z direction.'}, {'id': 'OG003', 'title': 'Combined', 'description': 'All participants are in this group, this simply defines the mean Combined force/moment (C).'}], 'classes': [{'title': 'Preload force (N)', 'categories': [{'measurements': [{'value': '-56.5', 'spread': '87.2', 'groupId': 'OG000'}, {'value': '-67.0', 'spread': '55.0', 'groupId': 'OG001'}, {'value': '-117.2', 'spread': '59.4', 'groupId': 'OG002'}, {'value': '170.3', 'spread': '64.9', 'groupId': 'OG003'}]}]}, {'title': 'Peak thrust force (N)', 'categories': [{'measurements': [{'value': '-128.3', 'spread': '163.4', 'groupId': 'OG000'}, {'value': '-172.3', 'spread': '141.9', 'groupId': 'OG001'}, {'value': '-276.4', 'spread': '137.1', 'groupId': 'OG002'}, {'value': '385.1', 'spread': '169.5', 'groupId': 'OG003'}]}]}], 'paramType': 'MEAN', 'timeFrame': '6 weeks', 'description': 'SSL\\* contains variables: maximum amplitude (Newton) during preload and peak thrust force in anterior-posterior (X), side-to-side (Y), head-to-toe direction (Z) and combined force (C).\n\n\\*Interpretation: the purpose of the outcomes is to quantify force-time profile of SM. The values of the outcome depend on the doctor who delivers SM, location and direction of SM, participant body position, and equipment. Currently there is no consensus regarding what value is higher than normal, normal, or lower than normal.\n\nSign convention: because patient position would affect the sign of some measurements, the right side up position was used as the reference position (i.e., the affected measurements assessed in the left side up position had their sign inverted) in order to calculate mean and SD. The value reported is the change from baseline to week 6.', 'unitOfMeasure': 'Newton (N)', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'typeUnitsAnalyzed': 'Spinal Manipulations', 'denomUnitsSelected': 'Spinal Manipulations', 'populationDescription': 'Note: 82, 71 and 68 participants completed at baseline, after 2 weeks and after 6 weeks, respectively, and a total of 593 SM was delivered during visits 1, 5, and 12. The number of observations for individual measures is lower than the total number of analyzable SM (n=575) due to missing data in corresponding components.'}, {'type': 'SECONDARY', 'title': 'Kinetic Measure - Spinal Segment Load (SSL) Moment', 'denoms': [{'units': 'Participants', 'counts': [{'value': '68', 'groupId': 'OG000'}, {'value': '68', 'groupId': 'OG001'}, {'value': '68', 'groupId': 'OG002'}, {'value': '68', 'groupId': 'OG003'}]}, {'units': 'Spinal Manipulations', 'counts': [{'value': '575', 'groupId': 'OG000'}, {'value': '575', 'groupId': 'OG001'}, {'value': '575', 'groupId': 'OG002'}, {'value': '575', 'groupId': 'OG003'}]}], 'groups': [{'id': 'OG000', 'title': 'Anterior-Posterior (X)', 'description': 'All participants are in this group, this simply defines the mean force/moment in the X direction.'}, {'id': 'OG001', 'title': 'Side-to-Side (Y)', 'description': 'All participants are in this group, this simply defines the mean force/moment in the Y direction.'}, {'id': 'OG002', 'title': 'Head-to-Toe (Z)', 'description': 'All participants are in this group, this simply defines the mean force/moment in the Z direction.'}, {'id': 'OG003', 'title': 'Combined', 'description': 'All participants are in this group, this simply defines the mean Combined force/moment (C).'}], 'classes': [{'title': 'Preload moment (N*M)', 'categories': [{'measurements': [{'value': '19.8', 'spread': '23.4', 'groupId': 'OG000'}, {'value': '-1.0', 'spread': '19.4', 'groupId': 'OG001'}, {'value': '-45.4', 'spread': '29.4', 'groupId': 'OG002'}, {'value': '58.5', 'spread': '27.8', 'groupId': 'OG003'}]}]}, {'title': 'Peak thrust moment (N*M)', 'categories': [{'measurements': [{'value': '31.0', 'spread': '46.0', 'groupId': 'OG000'}, {'value': '-3.4', 'spread': '39.9', 'groupId': 'OG001'}, {'value': '-76.0', 'spread': '42.2', 'groupId': 'OG002'}, {'value': '99.5', 'spread': '41.9', 'groupId': 'OG003'}]}]}], 'paramType': 'MEAN', 'timeFrame': '6 weeks', 'description': 'SSL\\* contains variables: maximum amplitude (Newton\\*Meter for moment) during preload and peak thrust force in anterior-posterior (X), side-to-side (Y), head-to-toe direction (Z) and combined force (C).\n\n\\*Interpretation: the purpose of the outcomes is to quantify force-time profile of SM. The values of the outcome depend on the doctor who delivers SM, location and direction of SM, participant body position, and equipment. Currently there is no consensus regarding what value is higher than normal, normal, or lower than normal.\n\nSign convention: because patient position would affect the sign of some measurements, the right side up position was used as the reference position (i.e., the affected measurements assessed in the left side up position had their sign inverted) in order to calculate mean and SD. The value reported is the change from baseline to week 6.', 'unitOfMeasure': 'Newton*Meter', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'typeUnitsAnalyzed': 'Spinal Manipulations', 'denomUnitsSelected': 'Spinal Manipulations', 'populationDescription': 'Note: 82, 71 and 68 participants completed at baseline, after 2 weeks and after 6 weeks, respectively, and a total of 593 SM was delivered during visits 1, 5, and 12. The number of observations for individual measures is lower than the total number of analyzable SM (n=575) due to missing data in corresponding components.'}, {'type': 'SECONDARY', 'title': 'Kinetic Measure - Spinal Segment Load (SSL) Rate of Loading for Force', 'denoms': [{'units': 'Participants', 'counts': [{'value': '68', 'groupId': 'OG000'}, {'value': '68', 'groupId': 'OG001'}, {'value': '68', 'groupId': 'OG002'}, {'value': '68', 'groupId': 'OG003'}]}, {'units': 'Spinal Manipulations', 'counts': [{'value': '575', 'groupId': 'OG000'}, {'value': '575', 'groupId': 'OG001'}, {'value': '575', 'groupId': 'OG002'}, {'value': '575', 'groupId': 'OG003'}]}], 'groups': [{'id': 'OG000', 'title': 'Anterior-Posterior (X)', 'description': 'All participants are in this group, this simply defines the mean force/moment in the X direction.'}, {'id': 'OG001', 'title': 'Side-to-Side (Y)', 'description': 'All participants are in this group, this simply defines the mean force/moment in the Y direction.'}, {'id': 'OG002', 'title': 'Head-to-Toe (Z)', 'description': 'All participants are in this group, this simply defines the mean force/moment in the Z direction.'}, {'id': 'OG003', 'title': 'Combined', 'description': 'All participants are in this group, this simply defines the mean Combined force/moment (C).'}], 'classes': [{'categories': [{'measurements': [{'value': '-599.2', 'spread': '897.1', 'groupId': 'OG000'}, {'value': '-598.1', 'spread': '668.8', 'groupId': 'OG001'}, {'value': '-1145.2', 'spread': '713.6', 'groupId': 'OG002'}, {'value': '1537.5', 'spread': '955.4', 'groupId': 'OG003'}]}]}], 'paramType': 'MEAN', 'timeFrame': '6 weeks', 'description': 'SSL\\* contains variables: rate of loading for force in anterior-posterior (X), side-to-side (Y), head-to-toe direction (Z) and combined force (C).\n\n\\*Interpretation: the purpose of the outcomes is to quantify force-time profile of SM. The values of the outcome depend on the doctor who delivers SM, location and direction of SM, participant body position, and equipment. Currently there is no consensus regarding what value is higher than normal, normal, or lower than normal.\n\nSign convention: because patient position would affect the sign of some measurements, the right side up position was used as the reference position (i.e., the affected measurements assessed in the left side up position had their sign inverted) in order to calculate mean and SD. The value reported is the change from baseline to week 6.', 'unitOfMeasure': 'Newton/second', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'typeUnitsAnalyzed': 'Spinal Manipulations', 'denomUnitsSelected': 'Spinal Manipulations', 'populationDescription': 'Note: 82, 71 and 68 participants completed at baseline, after 2 weeks and after 6 weeks, respectively, and a total of 593 SM was delivered during visits 1, 5, and 12. The number of observations for individual measures is lower than the total number of analyzable SM (n=575) due to missing data in corresponding components.'}, {'type': 'SECONDARY', 'title': 'Kinetic Measure - Spinal Segment Load (SSL) Rate of Loading for Moment', 'denoms': [{'units': 'Participants', 'counts': [{'value': '68', 'groupId': 'OG000'}, {'value': '68', 'groupId': 'OG001'}, {'value': '68', 'groupId': 'OG002'}, {'value': '68', 'groupId': 'OG003'}]}, {'units': 'Spinal Manipulations', 'counts': [{'value': '575', 'groupId': 'OG000'}, {'value': '575', 'groupId': 'OG001'}, {'value': '575', 'groupId': 'OG002'}, {'value': '575', 'groupId': 'OG003'}]}], 'groups': [{'id': 'OG000', 'title': 'Anterior-Posterior (X)', 'description': 'All participants are in this group, this simply defines the mean force/moment in the X direction.'}, {'id': 'OG001', 'title': 'Side-to-Side (Y)', 'description': 'All participants are in this group, this simply defines the mean force/moment in the Y direction.'}, {'id': 'OG002', 'title': 'Head-to-Toe (Z)', 'description': 'All participants are in this group, this simply defines the mean force/moment in the Z direction.'}, {'id': 'OG003', 'title': 'Combined', 'description': 'All participants are in this group, this simply defines the mean Combined force/moment (C).'}], 'classes': [{'categories': [{'measurements': [{'value': '51.3', 'spread': '201.8', 'groupId': 'OG000'}, {'value': '-40.4', 'spread': '183.7', 'groupId': 'OG001'}, {'value': '-210.2', 'spread': '159.0', 'groupId': 'OG002'}, {'value': '275.2', 'spread': '194.9', 'groupId': 'OG003'}]}]}], 'paramType': 'MEAN', 'timeFrame': '6 weeks', 'description': 'SSL\\* contains variables: rate of loading for moment in anterior-posterior (X), side-to-side (Y), head-to-toe direction (Z) and combined force (C).\n\n\\*Interpretation: the purpose of the outcomes is to quantify force-time profile of SM. The values of the outcome depend on the doctor who delivers SM, location and direction of SM, participant body position, and equipment. Currently there is no consensus regarding what value is higher than normal, normal, or lower than normal.\n\nSign convention: because patient position would affect the sign of some measurements, the right side up position was used as the reference position (i.e., the affected measurements assessed in the left side up position had their sign inverted) in order to calculate mean and SD. The value reported is the change from baseline to week 6.', 'unitOfMeasure': 'Newton*Meters/second', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'typeUnitsAnalyzed': 'Spinal Manipulations', 'denomUnitsSelected': 'Spinal Manipulations', 'populationDescription': 'Note: 82, 71 and 68 participants completed at baseline, after 2 weeks and after 6 weeks, respectively, and a total of 593 SM was delivered during visits 1, 5, and 12. The number of observations for individual measures is lower than the total number of analyzable SM (n=575) due to missing data in corresponding components.'}, {'type': 'SECONDARY', 'title': 'PROMIS-29 - Patient Reported Outcomes Measurement Information Scale-29: General Health Status Scale', 'denoms': [{'units': 'Participants', 'counts': [{'value': '82', 'groupId': 'OG000'}, {'value': '70', 'groupId': 'OG001'}, {'value': '68', 'groupId': 'OG002'}]}], 'groups': [{'id': 'OG000', 'title': 'HVLA-SM at Baseline', 'description': 'Result at baseline. Experimental High Velocity Low Amplitude Spinal Manipulation\n\nHVLA-SM: High Velocity Low Amplitude Spinal Manipulation'}, {'id': 'OG001', 'title': 'HVLA-SM After 2 Weeks', 'description': 'There is only one group/arm, this is the data for the same group of participants after two weeks.'}, {'id': 'OG002', 'title': 'HVLA-SM After 6 Weeks', 'description': 'There is only one group/arm, this is the data for the same group of participants after six weeks.'}], 'classes': [{'title': 'P29 - Anxiety', 'categories': [{'measurements': [{'value': '49.18', 'spread': '8.87', 'groupId': 'OG000'}, {'value': '47.93', 'spread': '7.87', 'groupId': 'OG001'}, {'value': '46.58', 'spread': '7.78', 'groupId': 'OG002'}]}]}, {'title': 'P29 - Depression', 'categories': [{'measurements': [{'value': '47.02', 'spread': '7.78', 'groupId': 'OG000'}, {'value': '45.97', 'spread': '7.07', 'groupId': 'OG001'}, {'value': '44.38', 'spread': '6.06', 'groupId': 'OG002'}]}]}, {'title': 'P29 - Fatigue', 'categories': [{'measurements': [{'value': '53.72', 'spread': '8.19', 'groupId': 'OG000'}, {'value': '51.93', 'spread': '7.84', 'groupId': 'OG001'}, {'value': '50.09', 'spread': '7.87', 'groupId': 'OG002'}]}]}, {'title': 'P-29 - Pain Interference', 'categories': [{'measurements': [{'value': '60.26', 'spread': '5.70', 'groupId': 'OG000'}, {'value': '57.78', 'spread': '6.37', 'groupId': 'OG001'}, {'value': '55.12', 'spread': '7.52', 'groupId': 'OG002'}]}]}, {'title': 'P29 - Physical Function', 'categories': [{'measurements': [{'value': '33.31', 'spread': '3.93', 'groupId': 'OG000'}, {'value': '32.29', 'spread': '3.84', 'groupId': 'OG001'}, {'value': '30.07', 'spread': '3.97', 'groupId': 'OG002'}]}]}, {'title': 'P29- Sleep Disturbance', 'categories': [{'measurements': [{'value': '52.23', 'spread': '3.13', 'groupId': 'OG000'}, {'value': '51.11', 'spread': '3.23', 'groupId': 'OG001'}, {'value': '51.79', 'spread': '3.10', 'groupId': 'OG002'}]}]}, {'title': 'P29 - Satisfaction w/ Participation in Social Role', 'categories': [{'measurements': [{'value': '45.45', 'spread': '6.84', 'groupId': 'OG000'}, {'value': '46.51', 'spread': '6.75', 'groupId': 'OG001'}, {'value': '49.75', 'spread': '7.71', 'groupId': 'OG002'}]}]}], 'paramType': 'MEAN', 'timeFrame': 'Baseline, 2 weeks, 6 weeks', 'description': "1\\) The questionnaire contains 7 PROMIS-29 specific items: Anxiety, Depression, Fatigue, Pain Interference, Physical Function, Sleep Disturbance, and Satisfaction with Participation in Social Role (anchors: 1= 'Not at all', 5= 'Very much', higher score is worse).\n\nEach PROMIS-29 specific item is reported in raw score (4-20) and scored in T-score (T), which rescales the raw score into a standardized score with a mean of 50 and a standard deviation (SD) of 10 for a population.\n\nOn the T-score metric \\& interpretation:\n\n* A score of 40 is one SD lower than the mean of the reference population.\n* A score of 60 is one SD higher than the mean of the reference population.\n* For PROMIS measures, higher scores equals more of the concept being measured (e.g., more Fatigue, more Physical Function). Thus a score of 60 is one standard deviation above the average referenced population. This could be a desirable or undesirable outcome, depending upon the concept being measured.", 'unitOfMeasure': 'T-score', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'populationDescription': 'Note: 82, 71 and 68 participants completed at baseline, after 2 weeks and after 6 weeks, respectively. Number of observations made at the three time points were 82, 70, and 68, respectively.'}, {'type': 'SECONDARY', 'title': 'PROMIS-29 - Patient Reported Outcomes Measurement Information Scale-29: Global Item, Pain NRS', 'denoms': [{'units': 'Participants', 'counts': [{'value': '82', 'groupId': 'OG000'}, {'value': '70', 'groupId': 'OG001'}, {'value': '68', 'groupId': 'OG002'}]}], 'groups': [{'id': 'OG000', 'title': 'HVLA-SM at Baseline', 'description': 'Result at baseline. Experimental High Velocity Low Amplitude Spinal Manipulation\n\nHVLA-SM: High Velocity Low Amplitude Spinal Manipulation'}, {'id': 'OG001', 'title': 'HVLA-SM After 2 Weeks', 'description': 'There is only one group/arm, this is the data for the same group of participants after two weeks.'}, {'id': 'OG002', 'title': 'HVLA-SM After 6 Weeks', 'description': 'There is only one group/arm, this is the data for the same group of participants after six weeks.'}], 'classes': [{'categories': [{'measurements': [{'value': '5.57', 'spread': '1.63', 'groupId': 'OG000'}, {'value': '4.46', 'spread': '1.95', 'groupId': 'OG001'}, {'value': '3.59', 'spread': '2.18', 'groupId': 'OG002'}]}]}], 'paramType': 'MEAN', 'timeFrame': 'Baseline, 2 weeks, 6 weeks', 'description': '1\\) The PROMIS questionnaire contains 1 PROMIS global item: Pain NRS, Scale: 0-10 (anchors: 0 = No Pain, 10 = Worst Imaginable Pain, higher score is worse). The PROMIS global item is not scored but reported in raw score.', 'unitOfMeasure': 'units on a scale', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'populationDescription': 'Note: 82, 71 and 68 participants completed at baseline, after 2 weeks and after 6 weeks, respectively. Number of observations made at the three time points were 82, 70, and 68, respectively.'}, {'type': 'SECONDARY', 'title': 'Bothersomeness', 'denoms': [{'units': 'Participants', 'counts': [{'value': '82', 'groupId': 'OG000'}, {'value': '70', 'groupId': 'OG001'}, {'value': '68', 'groupId': 'OG002'}]}], 'groups': [{'id': 'OG000', 'title': 'HVLA-SM at Baseline', 'description': 'Results at Baseline\n\nExperimental High Velocity Low Amplitude Spinal Manipulation\n\nHVLA-SM: High Velocity Low Amplitude Spinal Manipulation'}, {'id': 'OG001', 'title': 'HVLA-SM After 2 Weeks', 'description': 'There is only one group/arm, this is the data for the same group of participants after two weeks.'}, {'id': 'OG002', 'title': 'HVLA-SM After 6 Weeks', 'description': 'There is only one group/arm, this is the data for the same group of participants after six weeks.'}], 'classes': [{'title': 'Low Back Pain', 'categories': [{'measurements': [{'value': '6.18', 'spread': '1.93', 'groupId': 'OG000'}, {'value': '4.80', 'spread': '2.14', 'groupId': 'OG001'}, {'value': '3.63', 'spread': '2.30', 'groupId': 'OG002'}]}]}, {'title': 'Leg Pain (Sciatica)', 'categories': [{'measurements': [{'value': '3.29', 'spread': '3.18', 'groupId': 'OG000'}, {'value': '2.61', 'spread': '2.91', 'groupId': 'OG001'}, {'value': '1.94', 'spread': '2.68', 'groupId': 'OG002'}]}]}], 'paramType': 'MEAN', 'timeFrame': 'Baseline, 2 weeks, 6 weeks', 'description': 'Question asked of participants: "During the past week, how bothersome have each of the following symptoms been?" The bothersomeness questionnaire contains two items: a) low back pain \\& b) leg pain (sciatica).\n\nScale: 0-10 (anchors: 0 = Not at all bothersome, 10 = Extremely bothersome)', 'unitOfMeasure': 'units on a scale', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'populationDescription': 'Note: 82, 71 and 68 participants completed at baseline, after 2 weeks and after 6 weeks, respectively. Number of observations made at the three time points were 82, 70, and 68, respectively.'}]}, 'participantFlowModule': {'groups': [{'id': 'FG000', 'title': 'Experimental: HVLA-SM', 'description': 'Experimental High Velocity Low Amplitude Spinal Manipulation\n\nHVLA-SM: High Velocity Low Amplitude Spinal Manipulation\n\nParticipants receive treatments of HVLA-SM to the lumbar spine in the side-lying position. Treatment frequency is twice per week for 6 weeks.'}], 'periods': [{'title': 'Overall Study', 'milestones': [{'type': 'STARTED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '82'}]}, {'type': 'COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '68'}]}, {'type': 'NOT COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '14'}]}], 'dropWithdraws': [{'type': 'Lost to Follow-up', 'reasons': [{'groupId': 'FG000', 'numSubjects': '14'}]}]}]}, 'baselineCharacteristicsModule': {'denoms': [{'units': 'Participants', 'counts': [{'value': '82', 'groupId': 'BG000'}]}], 'groups': [{'id': 'BG000', 'title': 'Experimental: HVLA-SM', 'description': 'Experimental High Velocity Low Amplitude Spinal Manipulation\n\nHVLA-SM: High Velocity Low Amplitude Spinal Manipulation'}], 'measures': [{'title': 'Age, Continuous', 'classes': [{'categories': [{'measurements': [{'value': '44.9', 'spread': '10.6', 'groupId': 'BG000'}]}]}], 'paramType': 'MEAN', 'unitOfMeasure': 'years', 'dispersionType': 'STANDARD_DEVIATION'}, {'title': 'Sex: Female, Male', 'classes': [{'categories': [{'title': 'Female', 'measurements': [{'value': '39', 'groupId': 'BG000'}]}, {'title': 'Male', 'measurements': [{'value': '43', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Baseline Patient-Centered Outcome Measures', 'classes': [{'title': 'VAS', 'categories': [{'measurements': [{'value': '46.1', 'spread': '18.1', 'groupId': 'BG000'}]}]}, {'title': 'RMDQ', 'categories': [{'measurements': [{'value': '9.5', 'spread': '4.3', 'groupId': 'BG000'}]}]}], 'paramType': 'MEAN', 'description': 'VAS - Visual Analog Scale: The VAS is a single-item, unidimensional measure for pain. Score interpretations for the VAS include the following cut points: no pain (0 to 4 mm), mild pain (5 to 44 mm), moderate pain (45 to 74 mm), and severe pain (75 to 100 mm).\n\nRMDQ - Roland Morris disability questionnaire: The RMDQ consists of 24 questions related to disability, with each question worth one point. Scores can range from 0 (no disability) to 24 (severe disability).', 'unitOfMeasure': 'units on a scale', 'dispersionType': 'STANDARD_DEVIATION'}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'TREATMENT', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 82}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2012-09'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2017-10', 'completionDateStruct': {'date': '2014-06', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2017-10-25', 'studyFirstSubmitDate': '2012-08-02', 'resultsFirstSubmitDate': '2017-04-17', 'studyFirstSubmitQcDate': '2012-08-17', 'lastUpdatePostDateStruct': {'date': '2017-12-05', 'type': 'ACTUAL'}, 'resultsFirstSubmitQcDate': '2017-10-25', 'studyFirstPostDateStruct': {'date': '2012-08-22', 'type': 'ESTIMATED'}, 'resultsFirstPostDateStruct': {'date': '2017-12-05', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2014-06', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Patient-Centered Outcome Measurement Mean Change After 6 Weeks (VAS, RMDQ)', 'timeFrame': 'Baseline to 6 weeks', 'description': 'VAS - Visual Analog Scale - Scale: 0-100 mm (anchors: 0 mm = No Pain, 100 mm = Worst Imaginable Pain). VAS Interpretation: A higher score indicates greater pain intensity. In this study, improvement of 30% from the baseline value was considered clinically significant.\n\nRMDQ - Roland Morris disability questionnaire - Scale: 0 (no disability) to 24 (maximum disability). RMDQ Interpretation: Greater levels of disability are reflected by higher scores. In this study, improvement of 30% from the baseline value was considered clinically significant.'}, {'measure': 'Lumbar-spine Stiffness (LSS)', 'timeFrame': 'Baseline, 2 weeks, 6 weeks', 'description': 'LSS\\* contains 5 variables: global stiffness (GS, unit: Newton/mm) at L3 from 1) hand palpation 2) a hand-held device \\& 3) an automated indenter device; global stiffness variation (GSV, unit: Newton/mm) between GS from L1 to L5 from 4) hand palpation \\& 5) a hand-held device.\n\n\\*LSS Interpretation: The values of the outcome depend on testing procedure, instruction to participants, and equipment. Currently there is no consensus regarding what value is high than normal, normal, lower than normal.'}, {'measure': 'Lumbar-spine Stiffness (LSS) - Normalized Global Stiffness Variation', 'timeFrame': 'Baseline, 2 weeks, 6 weeks', 'description': 'LSS contains 2 variables: Palpatory and Handheld device - normalized global stiffness variation (nGSV, unitless).\n\nLSS Interpretation: The values of the outcome depend on testing procedure, instruction to participants, and equipment. Currently there is no consensus regarding what value is higher than normal, normal, lower than normal.'}, {'measure': 'Flexion-Relaxation Ratio (FRR)', 'timeFrame': 'Baseline, 2 weeks, 6 weeks', 'description': 'FRR contains 4 variables, which are the average right and left back muscle FRR obtained using 1) maximum EMG during flexion, and 2) maximum EMG during extension to normalize EMG during full flexion; and asymmetry between the right and left back muscle FRRs using 3) maximum EMG during flexion, and 4) maximum EMG during extension to normalize EMG during full flexion\n\nFRR Interpretation: The values of the outcome depend on testing procedure, instruction to participants, and equipment. Currently there is no consensus regarding what value is high than normal, normal, lower than normal.'}], 'secondaryOutcomes': [{'measure': 'Kinetic Measure - Spinal Segment Load (SSL) Force', 'timeFrame': '6 weeks', 'description': 'SSL\\* contains variables: maximum amplitude (Newton) during preload and peak thrust force in anterior-posterior (X), side-to-side (Y), head-to-toe direction (Z) and combined force (C).\n\n\\*Interpretation: the purpose of the outcomes is to quantify force-time profile of SM. The values of the outcome depend on the doctor who delivers SM, location and direction of SM, participant body position, and equipment. Currently there is no consensus regarding what value is higher than normal, normal, or lower than normal.\n\nSign convention: because patient position would affect the sign of some measurements, the right side up position was used as the reference position (i.e., the affected measurements assessed in the left side up position had their sign inverted) in order to calculate mean and SD. The value reported is the change from baseline to week 6.'}, {'measure': 'Kinetic Measure - Spinal Segment Load (SSL) Moment', 'timeFrame': '6 weeks', 'description': 'SSL\\* contains variables: maximum amplitude (Newton\\*Meter for moment) during preload and peak thrust force in anterior-posterior (X), side-to-side (Y), head-to-toe direction (Z) and combined force (C).\n\n\\*Interpretation: the purpose of the outcomes is to quantify force-time profile of SM. The values of the outcome depend on the doctor who delivers SM, location and direction of SM, participant body position, and equipment. Currently there is no consensus regarding what value is higher than normal, normal, or lower than normal.\n\nSign convention: because patient position would affect the sign of some measurements, the right side up position was used as the reference position (i.e., the affected measurements assessed in the left side up position had their sign inverted) in order to calculate mean and SD. The value reported is the change from baseline to week 6.'}, {'measure': 'Kinetic Measure - Spinal Segment Load (SSL) Rate of Loading for Force', 'timeFrame': '6 weeks', 'description': 'SSL\\* contains variables: rate of loading for force in anterior-posterior (X), side-to-side (Y), head-to-toe direction (Z) and combined force (C).\n\n\\*Interpretation: the purpose of the outcomes is to quantify force-time profile of SM. The values of the outcome depend on the doctor who delivers SM, location and direction of SM, participant body position, and equipment. Currently there is no consensus regarding what value is higher than normal, normal, or lower than normal.\n\nSign convention: because patient position would affect the sign of some measurements, the right side up position was used as the reference position (i.e., the affected measurements assessed in the left side up position had their sign inverted) in order to calculate mean and SD. The value reported is the change from baseline to week 6.'}, {'measure': 'Kinetic Measure - Spinal Segment Load (SSL) Rate of Loading for Moment', 'timeFrame': '6 weeks', 'description': 'SSL\\* contains variables: rate of loading for moment in anterior-posterior (X), side-to-side (Y), head-to-toe direction (Z) and combined force (C).\n\n\\*Interpretation: the purpose of the outcomes is to quantify force-time profile of SM. The values of the outcome depend on the doctor who delivers SM, location and direction of SM, participant body position, and equipment. Currently there is no consensus regarding what value is higher than normal, normal, or lower than normal.\n\nSign convention: because patient position would affect the sign of some measurements, the right side up position was used as the reference position (i.e., the affected measurements assessed in the left side up position had their sign inverted) in order to calculate mean and SD. The value reported is the change from baseline to week 6.'}, {'measure': 'PROMIS-29 - Patient Reported Outcomes Measurement Information Scale-29: General Health Status Scale', 'timeFrame': 'Baseline, 2 weeks, 6 weeks', 'description': "1\\) The questionnaire contains 7 PROMIS-29 specific items: Anxiety, Depression, Fatigue, Pain Interference, Physical Function, Sleep Disturbance, and Satisfaction with Participation in Social Role (anchors: 1= 'Not at all', 5= 'Very much', higher score is worse).\n\nEach PROMIS-29 specific item is reported in raw score (4-20) and scored in T-score (T), which rescales the raw score into a standardized score with a mean of 50 and a standard deviation (SD) of 10 for a population.\n\nOn the T-score metric \\& interpretation:\n\n* A score of 40 is one SD lower than the mean of the reference population.\n* A score of 60 is one SD higher than the mean of the reference population.\n* For PROMIS measures, higher scores equals more of the concept being measured (e.g., more Fatigue, more Physical Function). Thus a score of 60 is one standard deviation above the average referenced population. This could be a desirable or undesirable outcome, depending upon the concept being measured."}, {'measure': 'PROMIS-29 - Patient Reported Outcomes Measurement Information Scale-29: Global Item, Pain NRS', 'timeFrame': 'Baseline, 2 weeks, 6 weeks', 'description': '1\\) The PROMIS questionnaire contains 1 PROMIS global item: Pain NRS, Scale: 0-10 (anchors: 0 = No Pain, 10 = Worst Imaginable Pain, higher score is worse). The PROMIS global item is not scored but reported in raw score.'}, {'measure': 'Bothersomeness', 'timeFrame': 'Baseline, 2 weeks, 6 weeks', 'description': 'Question asked of participants: "During the past week, how bothersome have each of the following symptoms been?" The bothersomeness questionnaire contains two items: a) low back pain \\& b) leg pain (sciatica).\n\nScale: 0-10 (anchors: 0 = Not at all bothersome, 10 = Extremely bothersome)'}]}, 'oversightModule': {'oversightHasDmc': True}, 'conditionsModule': {'keywords': ['Low Back Pain'], 'conditions': ['Low Back Pain']}, 'referencesModule': {'references': [{'pmid': '25106673', 'type': 'BACKGROUND', 'citation': 'Xia T, Wilder DG, Gudavalli MR, DeVocht JW, Vining RD, Pohlman KA, Kawchuk GN, Long CR, Goertz CM. Study protocol for patient response to spinal manipulation - a prospective observational clinical trial on physiological and patient-centered outcomes in patients with chronic low back pain. BMC Complement Altern Med. 2014 Aug 8;14:292. doi: 10.1186/1472-6882-14-292.'}, {'pmid': '26500365', 'type': 'BACKGROUND', 'citation': 'Minkalis AL, Vining RD. What is the pain source? A case report of a patient with low back pain and bilateral hip osteonecrosis. J Can Chiropr Assoc. 2015 Sep;59(3):300-10.'}, {'pmid': '28599647', 'type': 'DERIVED', 'citation': 'Xia T, Long CR, Vining RD, Gudavalli MR, DeVocht JW, Kawchuk GN, Wilder DG, Goertz CM. Association of lumbar spine stiffness and flexion-relaxation phenomenon with patient-reported outcomes in adults with chronic low back pain - a single-arm clinical trial investigating the effects of thrust spinal manipulation. BMC Complement Altern Med. 2017 Jun 9;17(1):303. doi: 10.1186/s12906-017-1821-1.'}], 'seeAlsoLinks': [{'url': 'http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4139615/', 'label': 'Study protocol for patient response to spinal manipulation - a prospective observational clinical trial on physiological and patient-centered outcomes in patients with chronic low back pain'}, {'url': 'http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4593036/', 'label': 'What is the pain source? A case report of a patient with low back pain and bilateral hip osteonecrosis.'}]}, 'descriptionModule': {'briefSummary': 'This is a biomechanical study which is Project 1 in the Developmental Center for Clinical and Translational Research in Chiropractic (DCRC I) (NIH/NCCAM grant 1 U19 AT004663-01; principal investigator Christine Goertz, DC, PhD). This study is designed to monitor both physiological and patient self-report outcome variables. In addition, as there is little quantitative information on Spinal Manipulation Technique procedures reported in clinical trials, the study is designed to collect preliminary kinetic measures of the spinal manipulation technique delivery (i.e. force-time profiles).', 'detailedDescription': 'Participants with narrowly defined chronic low back pain will be included in this study. Each participant will be treated 12 times over the course of 6 weeks. The following data will be collected: participant characteristics that may predict outcome or be modifiers of force used by provider (gender, age, height, weight, and Body Mass Index); spinal segment load during the pre-load and thrusting phases (force and moment in the pre-load phase, peak load, and loading rate); physiological measures (posterior-anterior global stiffness and flexion-relaxation); patient-centered outcomes of back pain and function; and adverse events.\n\nStudy participants (n= 80) will be recruited from the Quad Cities metro area. A team of experienced chiropractic clinicians working at the Palmer Center for Chiropractic Research will treat study participants. Each of the study participants will receive 2 High Velocity Low Amplitude Spinal Manipulation treatment visits per week over a 6 week period. The physiological assessments will be performed immediately before and after Spinal Manipulation delivery during treatment visits 1, 5 \\& 12 (6 sets of assessments in total). During these same treatment visits, we will also capture the kinetic measures during Spinal Manipulation delivery for spinal segment load analysis. Participant patient-centered outcomes will be measured at baseline 1, and treatment visits 6 and 13. For simplicity, data collection time points will be named as baseline, after 2 weeks, and after 6 weeks.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'maximumAge': '65 Years', 'minimumAge': '21 Years', 'healthyVolunteers': True, 'eligibilityCriteria': "Inclusion Criteria:\n\n* NRS score, AVERAGE within the past 24 hours\n* Must be ≥4 at the phone screen or baseline 1 visit\n* Must be ≥2 at phone screen, baseline 1 and baseline 2 visits\n* Roland Morris Disability ≥6\n* Age 21-65\n* Signed informed consent document\n* Chronic (12+ weeks) low back pain\n\nExclusion Criteria:\n\n* Compliance concerns\n* No manipulable lesion in L1-L5 or SI joints\n* The absence of typical palpatory characteristics as well as the absence of a global assessment that would indicate that spinal manipulation is likely to generate a positive therapeutic effect, even without the presence of standard palpatory findings\n* Ongoing treatment for low back pain by outside provider\n* Comorbid conditions\n* Serious concomitant illness\n* Inflammatory or destructive spinal tissue change\n* Ankylosing Spondylytis\n* Fibromyalgia\n* Rheumatoid Arthritis\n* Confirmed or suspected disc herniation with neurological signs\n* Neuromuscular disease (e.g. Parkinson's, Muscular Dystrophy, Cerebral Palsy, or Myasthenia gravis\n* Spinal surgery \\<6 months\n* Suspicion of drug or alcohol dependence or abuse\n* Uncontrolled hypertension\n* Lower extremity peripheral arterial disease\n* Undetermined, infections or visceral source of low back pain\n* Other comorbid conditions prohibiting treatment and/or testing\n* Safety concerns\n* Bleeding disorders\n* Contraindications to High Velocity Low Amplitude Spinal Manipulation\n* Inability to tolerate or obtain positon for flexion-relaxation test without condition aggravation\n* Inability to tolerate or perform/receive any study procedure without condition aggravation\n* Quebec Task Force (QTF) criterion 4-11:\n* QTF 4: Pain + radiation to upper/lower limb with neurologic signs\n* QTF 5: Presumptive compression of a spinal nerve root on a simple roentgenogram\n* QTF 6: Compression of a spinal nerve root confirmed by specific imaging techniques\n* QTF 7: Spinal Stenosis\n* QTF 8: Postsurgical status, 1-6 months after intervention\n* QTF 9: Postsurgical status, \\>6 months after intervention\n* QTF 10: Chronic pain syndrome\n* QTF 11: Other diagnoses\n* Pregnancy\n* Pacemaker or defibrillator\n* Inability to read or verbally comprehend English\n* Joint replacement\n* Use of spinal manipulation within past 4 weeks\n* Sensitivity to adhesive\n* Diagnostic procedures other than x-ray/UA necessary\n* BDI-II ≥29\n* Retention of legal advice and open or pending case related to low back pain\n* BMI ≥40\n* Unwilling to have low back and wrist shaved\n* Moving from Quad Cities area within next 8 weeks\n* Unwilling to postpone treatments for low back pain from another provider\n* Seeking or receiving compensation for any disability"}, 'identificationModule': {'nctId': 'NCT01670292', 'acronym': 'PRiSM', 'briefTitle': 'Patient Response to Spinal Manipulation', 'organization': {'class': 'OTHER', 'fullName': 'Palmer College of Chiropractic'}, 'officialTitle': 'Patient Response to Spinal Manipulation', 'orgStudyIdInfo': {'id': 'PRiSM Study'}, 'secondaryIdInfos': [{'id': 'U19AT004663', 'link': 'https://reporter.nih.gov/quickSearch/U19AT004663', 'type': 'NIH'}]}, 'armsInterventionsModule': {'armGroups': [{'type': 'OTHER', 'label': 'Experimental: HVLA-SM', 'description': 'Experimental High Velocity Low Amplitude Spinal Manipulation', 'interventionNames': ['Other: HVLA-SM']}], 'interventions': [{'name': 'HVLA-SM', 'type': 'OTHER', 'description': 'High Velocity Low Amplitude Spinal Manipulation', 'armGroupLabels': ['Experimental: HVLA-SM']}]}, 'contactsLocationsModule': {'locations': [{'zip': '52803', 'city': 'Davenport', 'state': 'Iowa', 'country': 'United States', 'facility': 'Palmer College of Chiropractic', 'geoPoint': {'lat': 41.52364, 'lon': -90.57764}}], 'overallOfficials': [{'name': 'Ting Xia, PhD', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Palmer College of Chiropractic'}]}, 'ipdSharingStatementModule': {'ipdSharing': 'YES', 'description': 'Once the resulting manuscripts have been published, data sets will be provided for public access. Potential investigators can contact one of the Co-PIs to present their hypothesis, study design, instruments and/or data on which to focus, and resources required. Depending upon the needs and desires of the requesting party, the data that are shared may include analytic tables or de-identified or limited data sets that are transmitted to the requesting parties for additional analyses.'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Palmer College of Chiropractic', 'class': 'OTHER'}, 'collaborators': [{'name': 'University of Iowa', 'class': 'OTHER'}, {'name': 'National Center for Complementary and Integrative Health (NCCIH)', 'class': 'NIH'}], 'responsibleParty': {'type': 'SPONSOR'}}}}