Viewing Study NCT02297334


Ignite Creation Date: 2025-12-25 @ 2:34 AM
Ignite Modification Date: 2026-04-19 @ 1:26 AM
Study NCT ID: NCT02297334
Status: COMPLETED
Last Update Posted: 2017-08-29
First Post: 2014-10-08
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Removal of Cytokines During Extracorporeal Circulation in Cardiac Surgery
Sponsor: Universitätsklinikum Hamburg-Eppendorf
Organization:

Study Overview

Official Title: Reduction of Inflammation Reaction to Extracorporeal Circulation in Cardiac Surgery by Interleukin Dialysis
Status: COMPLETED
Status Verified Date: 2017-08
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The aim of this study is to prove that using a CytoSorb(TM) filter in the cardiopulmonary circuit attenuates the inflammatory response to extracorporeal circulation in patients undergoing cardiac surgery. The hypothesis is that removing cytokines from patients' blood by the CytoSorb device significantly improves circulation and outcome in patients undergoing on-pump cardiac surgery.
Detailed Description: Cardiac surgery with cardiopulmonary bypass (CPB) induces an inflammatory response due to contact of patients' blood with foreign surfaces like tubes or the oxygenator, ischemic-reperfusion injury and surgical trauma. Inflammation is modulated by cytokines, especially, interleukins. The extent of cytokine release is further related to the duration of bypass and the amount of operating field suction. This results in a systemic inflammatory response syndrome (SIRS) with the risk of multiple organ dysfunction (MOD). Also in patients treated with extracorporeal membrane oxygenation (ECMO) an activation of the inflammation system is seen and accompanied with an increase of cytokine levels. The cytokine concentration correlates with the severity of the immune reaction and can be a predictor of the outcome of the patient. As severe SIRS and MOD significantly increase mortality, the attenuation of the inflammatory response is supposed to reduce morbidity and mortality after cardiac surgery.

For adult cardiac surgery and patients who are treated with an extracorporal assist device, a tool for cytokine elimination and attenuation of the inflammatory response seems to be beneficial.

In our study we are going to investigate if the use of the CytoSorb device can improve the outcome of patients undergoing elective coronar artery bypass and heart valve surgery.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: