Viewing Study NCT04705493


Ignite Creation Date: 2025-12-25 @ 1:06 AM
Ignite Modification Date: 2025-12-25 @ 11:18 PM
Study NCT ID: NCT04705493
Status: COMPLETED
Last Update Posted: 2021-08-16
First Post: 2021-01-09
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Validation of Uncalibrated Cardiac Output Measurement With LiDCOrapid in the Resuscitation of Critically Ill Patients With Septic Shock: A Prospective Cross-sectional Study.
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D012772', 'term': 'Shock, Septic'}], 'ancestors': [{'id': 'D018805', 'term': 'Sepsis'}, {'id': 'D007239', 'term': 'Infections'}, {'id': 'D018746', 'term': 'Systemic Inflammatory Response Syndrome'}, {'id': 'D007249', 'term': 'Inflammation'}, {'id': 'D010335', 'term': 'Pathologic Processes'}, {'id': 'D013568', 'term': 'Pathological Conditions, Signs and Symptoms'}, {'id': 'D012769', 'term': 'Shock'}]}, 'interventionBrowseModule': {'meshes': [{'id': 'D000077324', 'term': 'Crystalloid Solutions'}], 'ancestors': [{'id': 'D007552', 'term': 'Isotonic Solutions'}, {'id': 'D012996', 'term': 'Solutions'}, {'id': 'D004364', 'term': 'Pharmaceutical Preparations'}]}}, 'protocolSection': {'designModule': {'studyType': 'OBSERVATIONAL', 'designInfo': {'timePerspective': 'CROSS_SECTIONAL', 'observationalModel': 'CASE_ONLY'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 40}, 'patientRegistry': False}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2019-12-01', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2021-08', 'completionDateStruct': {'date': '2021-07-01', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2021-08-12', 'studyFirstSubmitDate': '2021-01-09', 'studyFirstSubmitQcDate': '2021-01-09', 'lastUpdatePostDateStruct': {'date': '2021-08-16', 'type': 'ACTUAL'}, 'studyFirstPostDateStruct': {'date': '2021-01-12', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2021-07-01', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'primary outcome', 'timeFrame': 'on patient admission to the icu for 1 hour', 'description': 'To measure cardiac output difference between LiDCOrapid measurement and echocardiographic measurement .'}], 'secondaryOutcomes': [{'measure': 'secondary outcome', 'timeFrame': 'on patient admission to the icu for 1 hour', 'description': 'to measure dose of vasopressors and inotropic agents'}, {'measure': 'secondary outcome', 'timeFrame': 'on patient admission to the icu for 1 hour', 'description': 'to measure heart rate'}, {'measure': 'secondary outcome', 'timeFrame': 'on patient admission to the icu for 1 hour', 'description': 'to measure stroke volume'}, {'measure': 'secondary outcome', 'timeFrame': 'on patient admission to the icu for 1 hour', 'description': 'to detect stroke volume variation'}, {'measure': 'secondary outcome', 'timeFrame': 'on patient admission to the icu for 1 hour', 'description': 'to record mean arterial blood pressure'}]}, 'oversightModule': {'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': False}, 'conditionsModule': {'keywords': ['cardiac output , LIDCO . Septic shock'], 'conditions': ['Cardiac Output, LIDCO Rapid, Septic Shock']}, 'descriptionModule': {'briefSummary': 'Transthoracic echocardiography (TTE) has been used as a reference technique for CO measurement and its accuracy has been adequate for many clinical uses. TTE is painless, safe and non-invasive. Some drawbacks of TTE are being expensive, bulky and needs advanced training.\n\nCurrently, due to increased interest in minimally invasive hemodynamic monitoring, multiple new methods have become commercially available to assess CO: the arterial pulse aortic flow, bioreactance, and bioimpedance.\n\nOne of these new devices is LiDCOrapid (LiDCO Ltd, Cambridge, UK). It is a new, minimally invasive monitor which estimates beat-by-beat CO and fluid responsiveness from the arterial waveform.\n\nIt has been validated after vascular, urological and thoracic surgery and shows good agreement with the PA catheter in swine, in patients with normal left ventricular systolic function and in patients with vasodilatation. However, LiDCO has not yet been validated in patients with septic shock. Therefore, the aim of this study is to validate LiDCOrapid parameters in septic shock patients using TTE derived parameters as the non-invasive reference.', 'detailedDescription': "Obtaining a patient's cardiac output (CO) could contribute to optimized, safe hemodynamic control. Accurate CO measurements can serve as a guide for resuscitation therapy, catecholamine use, differential diagnosis, and intervention during a circulatory failure. Although the thermodilution technique via a pulmonary artery catheter (PAC) has an invasive and intermittent, it remains the gold standard for CO measurements.\n\nPreviously monitoring of CO required invasive and costly devices limiting their use to intensive care setting. More recently ultrasound is increasingly being used and offers a range of non-invasive tools to estimate CO.\n\nTransthoracic echocardiography (TTE) has been used as a reference technique for CO measurement and its accuracy has been adequate for many clinical uses. TTE is painless, safe and non-invasive. Some drawbacks of TTE are being expensive, bulky and needs advanced training.\n\nCurrently, due to increased interest in minimally invasive hemodynamic monitoring, multiple new methods have become commercially available to assess CO: the arterial pulse aortic flow, bioreactance, and bioimpedance.\n\nOne of these new devices is LiDCOrapid (LiDCO Ltd, Cambridge, UK). It is a new, minimally invasive monitor which estimates beat-by-beat CO and fluid responsiveness from the arterial waveform.\n\nIt has been validated after vascular, urological and thoracic surgery and shows good agreement with the PA catheter in swine, in patients with normal left ventricular systolic function and in patients with vasodilatation. However, LiDCO has not yet been validated in patients with septic shock. Therefore, the aim of this study is to validate LiDCOrapid parameters in septic shock patients using TTE derived parameters as the non-invasive reference."}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '18 Years', 'samplingMethod': 'NON_PROBABILITY_SAMPLE', 'studyPopulation': 'The study will be performed on any patient with septic shock admitted to the surgical ICU.', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n1. Age \\> 18 years.\n2. Patients admitted to ICU with septic shock\n\nExclusion Criteria:\n\n1. Patients with poor Echo window.\n2. If they presented with a history of heart failure, valvular disease or arrhythmias.'}, 'identificationModule': {'nctId': 'NCT04705493', 'briefTitle': 'Validation of Uncalibrated Cardiac Output Measurement With LiDCOrapid in the Resuscitation of Critically Ill Patients With Septic Shock: A Prospective Cross-sectional Study.', 'organization': {'class': 'OTHER', 'fullName': 'Cairo University'}, 'officialTitle': 'Validation of Uncalibrated Cardiac Output Measurement With LiDCOrapid in the Resuscitation of Critically Ill Patients With Septic Shock: A Prospective Cross-sectional Study', 'orgStudyIdInfo': {'id': 'MD-84-2019'}}, 'armsInterventionsModule': {'armGroups': [{'label': 'CASE GROUP', 'description': 'Lidco rapid examination and echo examination were done to septic shock patients then the passive leg raising test was done and fluid responder cases were given mini fluid challenge and fluid challenge', 'interventionNames': ['Other: fluid resuscitation with crystalloid']}], 'interventions': [{'name': 'fluid resuscitation with crystalloid', 'type': 'OTHER', 'description': 'give two-volume of fluids initial 250ml then another 250 ml', 'armGroupLabels': ['CASE GROUP']}]}, 'contactsLocationsModule': {'locations': [{'zip': '11211', 'city': 'Cairo', 'country': 'Egypt', 'facility': 'Kasr El Ainy Shcool of Medicine', 'geoPoint': {'lat': 30.06263, 'lon': 31.24967}}]}, 'ipdSharingStatementModule': {'ipdSharing': 'UNDECIDED'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Cairo University', 'class': 'OTHER'}, 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'MSC', 'investigatorFullName': 'Magdy Abdelmohsen Elsayed Mohamed', 'investigatorAffiliation': 'Cairo University'}}}}