Viewing Study NCT02156167


Ignite Creation Date: 2025-12-25 @ 12:39 AM
Ignite Modification Date: 2026-02-25 @ 7:07 PM
Study NCT ID: NCT02156167
Status: COMPLETED
Last Update Posted: 2016-07-21
First Post: 2014-06-03
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: Clinical Assessment of the External Sound Processor Worn by Patients Implanted With Codacs
Sponsor:
Organization:

Raw JSON

{'hasResults': True, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D010040', 'term': 'Otosclerosis'}], 'ancestors': [{'id': 'D004427', 'term': 'Ear Diseases'}, {'id': 'D010038', 'term': 'Otorhinolaryngologic Diseases'}]}}, 'resultsSection': {'moreInfoModule': {'pointOfContact': {'email': 'cdhondt@cochlear.com', 'phone': '+32 15 76 55 14', 'title': "Christiane D'hondt, Clinical Research Specialist", 'organization': 'Cochlear'}, 'certainAgreement': {'restrictionType': 'LTE60', 'piSponsorEmployee': False, 'restrictiveAgreement': True}}, 'adverseEventsModule': {'timeFrame': 'March 2014 to June 2015', 'eventGroups': [{'id': 'EG000', 'title': 'CP810', 'description': 'Nucleus® CP810 Sound Processor for the Codacs™ system (CE marked)', 'otherNumAtRisk': 15, 'otherNumAffected': 0, 'seriousNumAtRisk': 15, 'seriousNumAffected': 0}], 'frequencyThreshold': '0'}, 'outcomeMeasuresModule': {'outcomeMeasures': [{'type': 'PRIMARY', 'title': 'Aided Speech Reception Threshold (SRT) in Noise Measured by Signal to Noise Ratio for 50% Correct Scores With the Oldenburger Sentence Test', 'denoms': [{'units': 'Participants', 'counts': [{'value': '13', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'CP810', 'description': 'Nucleus® CP810 Sound Processor for the Codacs™ system (CE marked)'}], 'classes': [{'title': 'S0N0 - E - Freedom', 'categories': [{'measurements': [{'value': '-0.83', 'spread': '2.04', 'groupId': 'OG000'}]}]}, {'title': 'S0N0 - E - CP810', 'categories': [{'measurements': [{'value': '-1.45', 'spread': '2.29', 'groupId': 'OG000'}]}]}, {'title': 'S0N90 - E - Freedom', 'categories': [{'measurements': [{'value': '0.64', 'spread': '2.92', 'groupId': 'OG000'}]}]}, {'title': 'S0N90 - E - CP810', 'categories': [{'measurements': [{'value': '0.89', 'spread': '2.83', 'groupId': 'OG000'}]}]}, {'title': 'S0N0 - N - CP810', 'categories': [{'measurements': [{'value': '-1.22', 'spread': '1.69', 'groupId': 'OG000'}]}]}, {'title': 'S0N90 - N - CP810', 'categories': [{'measurements': [{'value': '-3.78', 'spread': '3.33', 'groupId': 'OG000'}]}]}], 'paramType': 'MEAN', 'timeFrame': '3 months after initial upgraded fitting', 'description': 'The Oldenburger Sentence test is an adaptive speech in noise test with a fixed noise level of typically 65 decibel (dB) sound pressure level (SPL) and a varying speech level, depending on how many words in a sentence were repeated correctly by the subject. The outcome of this test is the signal-to-noise ratio (SNR) at which 50% of words in the sentence list were correctly repeated by the subject. The SRT in noise with the Freedom sound processor at the initial study visit was compared to the SRT in noise with the CP810 at the 3 months follow-up at different measurement conditions.\n\nSpeech and noise coming from the front (S0N0)- Speech coming from the front and noise coming from the implanted side (S0N90)- Everyday program (E): omnidirectional microphone- Noise program (N): directional microphone- Freedom Sound Processor (Freedom)- CP810 Sound Processor (CP810).', 'unitOfMeasure': 'dB SNR', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'populationDescription': 'One subject did not visit the clinic for the 3 months follow-up, a second subject did not perform the speech in noise test at the 3 months follow-up due to tiredness'}]}, 'participantFlowModule': {'groups': [{'id': 'FG000', 'title': 'CP810', 'description': 'Nucleus® CP810 Sound Processor for the Codacs™ system (CE marked)'}], 'periods': [{'title': 'Overall Study', 'milestones': [{'type': 'STARTED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '15'}]}, {'type': 'COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '15'}]}, {'type': 'NOT COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '0'}]}]}], 'recruitmentDetails': 'Center contacted their patients, who received a Codacs device in another clinical trial by phone in October 2013'}, 'baselineCharacteristicsModule': {'denoms': [{'units': 'Participants', 'counts': [{'value': '15', 'groupId': 'BG000'}]}], 'groups': [{'id': 'BG000', 'title': 'CP810', 'description': 'Nucleus® CP810 Sound Processor for the Codacs™ system (CE marked)'}], 'measures': [{'title': 'Age, Categorical', 'classes': [{'categories': [{'title': '<=18 years', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Between 18 and 65 years', 'measurements': [{'value': '6', 'groupId': 'BG000'}]}, {'title': '>=65 years', 'measurements': [{'value': '9', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Age, Continuous', 'classes': [{'categories': [{'measurements': [{'value': '66', 'groupId': 'BG000', 'lowerLimit': '53', 'upperLimit': '77'}]}]}], 'paramType': 'MEAN', 'unitOfMeasure': 'years', 'dispersionType': 'FULL_RANGE'}, {'title': 'Sex: Female, Male', 'classes': [{'categories': [{'title': 'Female', 'measurements': [{'value': '12', 'groupId': 'BG000'}]}, {'title': 'Male', 'measurements': [{'value': '3', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Region of Enrollment', 'classes': [{'title': 'Germany', 'categories': [{'measurements': [{'value': '15', 'groupId': 'BG000'}]}]}], 'paramType': 'NUMBER', 'unitOfMeasure': 'participants'}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'TREATMENT', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 15}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2014-03'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2015-07', 'completionDateStruct': {'date': '2015-06', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2016-06-09', 'studyFirstSubmitDate': '2014-06-03', 'resultsFirstSubmitDate': '2016-06-09', 'studyFirstSubmitQcDate': '2014-06-03', 'lastUpdatePostDateStruct': {'date': '2016-07-21', 'type': 'ESTIMATED'}, 'resultsFirstSubmitQcDate': '2016-06-09', 'studyFirstPostDateStruct': {'date': '2014-06-05', 'type': 'ESTIMATED'}, 'resultsFirstPostDateStruct': {'date': '2016-07-21', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2015-06', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Aided Speech Reception Threshold (SRT) in Noise Measured by Signal to Noise Ratio for 50% Correct Scores With the Oldenburger Sentence Test', 'timeFrame': '3 months after initial upgraded fitting', 'description': 'The Oldenburger Sentence test is an adaptive speech in noise test with a fixed noise level of typically 65 decibel (dB) sound pressure level (SPL) and a varying speech level, depending on how many words in a sentence were repeated correctly by the subject. The outcome of this test is the signal-to-noise ratio (SNR) at which 50% of words in the sentence list were correctly repeated by the subject. The SRT in noise with the Freedom sound processor at the initial study visit was compared to the SRT in noise with the CP810 at the 3 months follow-up at different measurement conditions.\n\nSpeech and noise coming from the front (S0N0)- Speech coming from the front and noise coming from the implanted side (S0N90)- Everyday program (E): omnidirectional microphone- Noise program (N): directional microphone- Freedom Sound Processor (Freedom)- CP810 Sound Processor (CP810).'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'keywords': ['Otosclerosis, cochlear implant, acoustic stimulation'], 'conditions': ['Severe to Profound Mixed Hearing Loss']}, 'referencesModule': {'references': [{'pmid': '23921930', 'type': 'BACKGROUND', 'citation': "Lenarz T, Zwartenkot JW, Stieger C, Schwab B, Mylanus EA, Caversaccio M, Kompis M, Snik AF, D'hondt C, Mojallal H. Multicenter study with a direct acoustic cochlear implant. Otol Neurotol. 2013 Sep;34(7):1215-25. doi: 10.1097/MAO.0b013e318298aa76."}, {'pmid': '24556905', 'type': 'BACKGROUND', 'citation': "Lenarz T, Verhaert N, Desloovere C, Desmet J, D'hondt C, Gonzalez JC, Kludt E, Macias AR, Skarzynski H, Van de Heyning P, Vyncke C, Wasowski A. A comparative study on speech in noise understanding with a direct acoustic cochlear implant in subjects with severe to profound mixed hearing loss. Audiol Neurootol. 2014;19(3):164-74. doi: 10.1159/000358004. Epub 2014 Feb 18."}]}, 'descriptionModule': {'briefSummary': 'The purpose of this study is to evaluate the effect of the sound processor upgrade from the C-DACS investigational device Freedom sound processor to the Nucleus® CP810 sound processor for the Codacs™ system on the speech reception threshold in noise, to evaluate the usability of the Codacs™ Fitting Software, to evaluate the quality of life with the Nucleus® CP810 Sound Processor for the Codacs™ system, to collect long term data, to evaluate the acceptance criteria of the postoperative Codacs™ system test and to evaluate the usability of the Codacs™ Test System.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['CHILD', 'ADULT', 'OLDER_ADULT'], 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Subjects implanted with a Cochlear C-DACS investigational device\n\nExclusion Criteria:\n\n* Participation in another medical device study\n* Unwillingness or inability of the subject to comply with the study requirements'}, 'identificationModule': {'nctId': 'NCT02156167', 'briefTitle': 'Clinical Assessment of the External Sound Processor Worn by Patients Implanted With Codacs', 'organization': {'class': 'INDUSTRY', 'fullName': 'Cochlear'}, 'officialTitle': 'Clinical Validation of the Nucleus® CP810 Sound Processor for the Codacs™ System', 'orgStudyIdInfo': {'id': 'CEL5441'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'CP810 and Codacs™Test System', 'description': 'Nucleus® CP810 Sound Processor for the Codacs™ system (CE marked) and Codacs™ Test System (CE marked)', 'interventionNames': ['Device: CP810 and Codacs™ system test']}], 'interventions': [{'name': 'CP810 and Codacs™ system test', 'type': 'DEVICE', 'description': 'Nucleus® CP810 Sound Processor for the Codacs™ system (CE marked) and Codacs™ Test System (CE marked)', 'armGroupLabels': ['CP810 and Codacs™Test System']}]}, 'contactsLocationsModule': {'locations': [{'zip': '30625', 'city': 'Hanover', 'state': 'Lower Saxony', 'country': 'Germany', 'facility': 'Hannover Medical School', 'geoPoint': {'lat': 52.37052, 'lon': 9.73322}}], 'overallOfficials': [{'name': 'Ernst von Wallenberg, PhD', 'role': 'STUDY_DIRECTOR', 'affiliation': 'Cochlear'}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Cochlear', 'class': 'INDUSTRY'}, 'responsibleParty': {'type': 'SPONSOR'}}}}