Viewing Study NCT05968495


Ignite Creation Date: 2025-12-24 @ 2:04 PM
Ignite Modification Date: 2026-01-04 @ 2:53 AM
Study NCT ID: NCT05968495
Status: COMPLETED
Last Update Posted: 2025-02-03
First Post: 2023-07-05
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: Measuring Renuvion Soft Tissue Contraction Using Ultrasound
Sponsor:
Organization:

Raw JSON

{'hasResults': True, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24', 'submissionTracking': {'firstMcpInfo': {'postDateStruct': {'date': '2024-12-27', 'type': 'ACTUAL'}}}}, 'conditionBrowseModule': {'meshes': [{'id': 'D003483', 'term': 'Cutis Laxa'}], 'ancestors': [{'id': 'D012873', 'term': 'Skin Diseases, Genetic'}, {'id': 'D030342', 'term': 'Genetic Diseases, Inborn'}, {'id': 'D009358', 'term': 'Congenital, Hereditary, and Neonatal Diseases and Abnormalities'}, {'id': 'D003240', 'term': 'Connective Tissue Diseases'}, {'id': 'D017437', 'term': 'Skin and Connective Tissue Diseases'}, {'id': 'D012871', 'term': 'Skin Diseases'}]}}, 'resultsSection': {'moreInfoModule': {'pointOfContact': {'email': 'cnichols@pearlplasticsurgery.com', 'phone': '360-878-9300', 'title': 'Christopher Nichols, MD', 'organization': 'Pearl Plastic Surgery'}, 'certainAgreement': {'otherDetails': 'The data produced by this sponsored study is the sole property of Sponsor. Sponsor must be provided with the opportunity to review all Investigator-prepared abstracts, publications, or presentations for a period of thirty (30) days for presentational materials and abstracts and forty-five (45) days for manuscripts.', 'restrictionType': 'OTHER', 'piSponsorEmployee': False, 'restrictiveAgreement': True}}, 'adverseEventsModule': {'timeFrame': '365 Days', 'description': 'An expected treatment effect was defined as any typical treatment side-effect of Renuvion APR System of mild to moderate severity and lasting up to a typical maximum duration. An adverse event was defined as any new medical problem, or exacerbation of an existing problem, experienced by a subject while enrolled in the study, whether or not it is considered device-related by the investigator.', 'eventGroups': [{'id': 'EG000', 'title': 'Renuvion APR System Treatment', 'description': 'Subjects are receiving treatment with the Renuvion APR system following power-assisted liposuction in the abdomen per investigator standard of care. Subjects may also have other body areas treated at the same time.\n\nRenuvion APR Handpiece: The Renuvion® APR (Apyx Plasma/RF) handpiece is a sterile, single use electrosurgical (monopolar) device intended to be used in conjunction with a compatible generator for the delivery of radiofrequency energy and helium plasma for cutting, coagulation and ablation of soft tissue during open surgical procedures. Radiofrequency energy is delivered to the handpiece by the generator and used to energize the electrode. When helium gas is passed over the energized electrode, a helium plasma is generated for cutting, coagulation or ablation of soft tissue during open surgical procedures. The compatible generators operate at an adjustable power of up to 40 W (expressed as 0 - 100% where 100% is 40 W) and provide an adjustable helium gas flow of 1 - 5 L/Min. APR Handpiece has a non-extendable electrode to generate helium plasma.', 'otherNumAtRisk': 5, 'deathsNumAtRisk': 5, 'otherNumAffected': 5, 'seriousNumAtRisk': 5, 'deathsNumAffected': 0, 'seriousNumAffected': 0}], 'otherEvents': [{'term': 'Seroma', 'notes': 'These minor seromas were only visible by ultrasound and would have typically gone un-reported had it not been for the ultrasound component of this study.', 'stats': [{'groupId': 'EG000', 'numAtRisk': 5, 'numEvents': 3, 'numAffected': 3}], 'organSystem': 'Surgical and medical procedures', 'assessmentType': 'NON_SYSTEMATIC_ASSESSMENT'}, {'term': 'Subcutaneous Nodule', 'stats': [{'groupId': 'EG000', 'numAtRisk': 5, 'numEvents': 3, 'numAffected': 3}], 'organSystem': 'Skin and subcutaneous tissue disorders', 'assessmentType': 'NON_SYSTEMATIC_ASSESSMENT'}, {'term': 'Hypoesthesia/numbness (ETE)', 'stats': [{'groupId': 'EG000', 'numAtRisk': 5, 'numEvents': 1, 'numAffected': 1}], 'organSystem': 'Skin and subcutaneous tissue disorders', 'assessmentType': 'NON_SYSTEMATIC_ASSESSMENT'}], 'frequencyThreshold': '0'}, 'outcomeMeasuresModule': {'outcomeMeasures': [{'type': 'PRIMARY', 'title': 'Analysis of Contraction From Baseline to Day 365', 'denoms': [{'units': 'Participants', 'counts': [{'value': '4', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Renuvion APR System Treatment', 'description': 'Subjects are receiving treatment with the Renuvion APR system following power-assisted liposuction in the abdomen per investigator standard of care. Subjects may also have other body areas treated at the same time.\n\nRenuvion APR Handpiece: The Renuvion® APR (Apyx Plasma/RF) handpiece is a sterile, single use electrosurgical (monopolar) device intended to be used in conjunction with a compatible generator for the delivery of radiofrequency energy and helium plasma for cutting, coagulation and ablation of soft tissue during open surgical procedures. Radiofrequency energy is delivered to the handpiece by the generator and used to energize the electrode. When helium gas is passed over the energized electrode, a helium plasma is generated for cutting, coagulation or ablation of soft tissue during open surgical procedures. The compatible generators operate at an adjustable power of up to 40 W (expressed as 0 - 100% where 100% is 40 W) and provide an adjustable helium gas flow of 1 - 5 L/Min. APR Handpiece has a non-extendable electrode to generate helium plasma.'}], 'classes': [{'categories': [{'measurements': [{'value': '-44.0', 'spread': '17.2', 'groupId': 'OG000'}]}]}], 'paramType': 'MEAN', 'timeFrame': 'Baseline, Day 365', 'description': "Percentage of soft tissue contraction measured by an ultrasonographer on baseline ultrasound images compared to follow-up images to quantify the total amount of connective tissue contraction produced by the Renuvion treatment between the skin and the Scarpa's fascia. A negative value indicates greater tissue contraction, while a positive value indicates less tissue contraction.", 'unitOfMeasure': 'percentage of contraction', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'populationDescription': 'During this initial study treatment, the investigators realized the importance of fully expressing the helium from the tissue prior to taking the intra-operative measurements as residual helium expands the subcutaneous tissue, resulting in inaccurate contraction measurements. Due to this discovery and the subsequent change in treatment technique for the remaining subjects, the data for subject 001-BBJ is excluded from the intra-operative data tables and analysis.'}, {'type': 'SECONDARY', 'title': 'IPR Review', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}, {'units': 'Sets of images analyzed', 'counts': [{'value': '19', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Renuvion APR System Treatment', 'description': 'Subjects are receiving treatment with the Renuvion APR system following power-assisted liposuction in the abdomen per investigator standard of care. Subjects may also have other body areas treated at the same time.\n\nRenuvion APR Handpiece: The Renuvion® APR (Apyx Plasma/RF) handpiece is a sterile, single use electrosurgical (monopolar) device intended to be used in conjunction with a compatible generator for the delivery of radiofrequency energy and helium plasma for cutting, coagulation and ablation of soft tissue during open surgical procedures. Radiofrequency energy is delivered to the handpiece by the generator and used to energize the electrode. When helium gas is passed over the energized electrode, a helium plasma is generated for cutting, coagulation or ablation of soft tissue during open surgical procedures. The compatible generators operate at an adjustable power of up to 40 W (expressed as 0 - 100% where 100% is 40 W) and provide an adjustable helium gas flow of 1 - 5 L/Min. APR Handpiece has a non-extendable electrode to generate helium plasma.'}], 'classes': [{'categories': [{'measurements': [{'value': '18', 'groupId': 'OG000'}]}]}], 'paramType': 'NUMBER', 'timeFrame': 'Day 365', 'description': 'Three experienced, blinded photographic reviewers performed a qualitative analysis/review of pre-treatment and post-treatment sets of images at 90-days, 180-days, 270-days, and 365-days post-treatment compared to baseline for each subject. Images were provided in a blinded and randomized order. Each blinded reviewer choose which set of images were the post-treated Renuvion images of the abdomen. Success was the correct identification of treated abdomen images by at least 2 of the 3 reviewers.', 'unitOfMeasure': 'Correctly identified sets of images', 'reportingStatus': 'POSTED', 'typeUnitsAnalyzed': 'Sets of images analyzed', 'denomUnitsSelected': 'Sets of images analyzed'}, {'type': 'SECONDARY', 'title': 'Physician Global Aesthetic Improvement', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Renuvion APR System Treatment', 'description': 'Subjects are receiving treatment with the Renuvion APR system following power-assisted liposuction in the abdomen per investigator standard of care. Subjects may also have other body areas treated at the same time.\n\nRenuvion APR Handpiece: The Renuvion® APR (Apyx Plasma/RF) handpiece is a sterile, single use electrosurgical (monopolar) device intended to be used in conjunction with a compatible generator for the delivery of radiofrequency energy and helium plasma for cutting, coagulation and ablation of soft tissue during open surgical procedures. Radiofrequency energy is delivered to the handpiece by the generator and used to energize the electrode. When helium gas is passed over the energized electrode, a helium plasma is generated for cutting, coagulation or ablation of soft tissue during open surgical procedures. The compatible generators operate at an adjustable power of up to 40 W (expressed as 0 - 100% where 100% is 40 W) and provide an adjustable helium gas flow of 1 - 5 L/Min. APR Handpiece has a non-extendable electrode to generate helium plasma.'}], 'classes': [{'title': 'Day 60', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'categories': [{'title': 'Worse', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'No change', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'Improved, Much Improved, Very Much Improved', 'measurements': [{'value': '5', 'groupId': 'OG000'}]}]}, {'title': 'Day 90', 'denoms': [{'units': 'Participants', 'counts': [{'value': '4', 'groupId': 'OG000'}]}], 'categories': [{'title': 'Worse', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'No change', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'Improved, Much Improved, Very Much Improved', 'measurements': [{'value': '4', 'groupId': 'OG000'}]}]}, {'title': 'Day 180', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'categories': [{'title': 'Worse', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'No change', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'Improved, Much Improved, Very Much Improved', 'measurements': [{'value': '5', 'groupId': 'OG000'}]}]}, {'title': 'Day 270', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'categories': [{'title': 'Worse', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'No change', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'Improved, Much Improved, Very Much Improved', 'measurements': [{'value': '5', 'groupId': 'OG000'}]}]}, {'title': 'Day 365', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'categories': [{'title': 'Worse', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'No change', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'Improved, Much Improved, Very Much Improved', 'measurements': [{'value': '5', 'groupId': 'OG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'timeFrame': 'Day 60, Day 90, Day 180, Day 270, Day 365', 'description': 'The Principal Investigator, sub-investigator or qualified clinician delegated by the principal investigator, will complete a PGAIS assessing overall aesthetic improvement in the treatment area.', 'unitOfMeasure': 'Participants', 'reportingStatus': 'POSTED', 'populationDescription': 'One subject missed the D90 visit.'}, {'type': 'SECONDARY', 'title': 'Subject Global Aesthetic Improvement', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Renuvion APR System Treatment', 'description': 'Subjects are receiving treatment with the Renuvion APR system following power-assisted liposuction in the abdomen per investigator standard of care. Subjects may also have other body areas treated at the same time.\n\nRenuvion APR Handpiece: The Renuvion® APR (Apyx Plasma/RF) handpiece is a sterile, single use electrosurgical (monopolar) device intended to be used in conjunction with a compatible generator for the delivery of radiofrequency energy and helium plasma for cutting, coagulation and ablation of soft tissue during open surgical procedures. Radiofrequency energy is delivered to the handpiece by the generator and used to energize the electrode. When helium gas is passed over the energized electrode, a helium plasma is generated for cutting, coagulation or ablation of soft tissue during open surgical procedures. The compatible generators operate at an adjustable power of up to 40 W (expressed as 0 - 100% where 100% is 40 W) and provide an adjustable helium gas flow of 1 - 5 L/Min. APR Handpiece has a non-extendable electrode to generate helium plasma.'}], 'classes': [{'title': 'Day 60', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'categories': [{'title': 'Worse', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'No Change', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'Improved, Much Improved, Very Much Improved', 'measurements': [{'value': '5', 'groupId': 'OG000'}]}]}, {'title': 'Day 90', 'denoms': [{'units': 'Participants', 'counts': [{'value': '4', 'groupId': 'OG000'}]}], 'categories': [{'title': 'Worse', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'No Change', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'Improved, Much Improved, Very Much Improved', 'measurements': [{'value': '4', 'groupId': 'OG000'}]}]}, {'title': 'Day 180', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'categories': [{'title': 'Worse', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'No Change', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'Improved, Much Improved, Very Much Improved', 'measurements': [{'value': '5', 'groupId': 'OG000'}]}]}, {'title': 'Day 270', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'categories': [{'title': 'Worse', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'No Change', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'Improved, Much Improved, Very Much Improved', 'measurements': [{'value': '5', 'groupId': 'OG000'}]}]}, {'title': 'Day 365', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'categories': [{'title': 'Worse', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'No Change', 'measurements': [{'value': '0', 'groupId': 'OG000'}]}, {'title': 'Improved, Much Improved, Very Much Improved', 'measurements': [{'value': '5', 'groupId': 'OG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'timeFrame': 'Day 60, Day 90, Day 180, Day 270, Day 365', 'description': 'The subject will complete a SGAIS assessing overall aesthetic improvement in the treatment area.', 'unitOfMeasure': 'Participants', 'reportingStatus': 'POSTED', 'populationDescription': 'One subject missed the D90 visit.'}, {'type': 'SECONDARY', 'title': 'Patient Satisfaction', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Renuvion APR System Treatment', 'description': 'Subjects are receiving treatment with the Renuvion APR system following power-assisted liposuction in the abdomen per investigator standard of care. Subjects may also have other body areas treated at the same time.\n\nRenuvion APR Handpiece: The Renuvion® APR (Apyx Plasma/RF) handpiece is a sterile, single use electrosurgical (monopolar) device intended to be used in conjunction with a compatible generator for the delivery of radiofrequency energy and helium plasma for cutting, coagulation and ablation of soft tissue during open surgical procedures. Radiofrequency energy is delivered to the handpiece by the generator and used to energize the electrode. When helium gas is passed over the energized electrode, a helium plasma is generated for cutting, coagulation or ablation of soft tissue during open surgical procedures. The compatible generators operate at an adjustable power of up to 40 W (expressed as 0 - 100% where 100% is 40 W) and provide an adjustable helium gas flow of 1 - 5 L/Min. APR Handpiece has a non-extendable electrode to generate helium plasma.'}], 'classes': [{'title': 'Characterize Satisfaction with Procedure: Satisfied (Very, Satisfied, or Slightly)', 'categories': [{'measurements': [{'value': '5', 'groupId': 'OG000'}]}]}, {'title': 'Noticed improvement in how abdomen looks', 'categories': [{'measurements': [{'value': '5', 'groupId': 'OG000'}]}]}, {'title': 'Recommends Procedure to Friends and Family Members', 'categories': [{'measurements': [{'value': '5', 'groupId': 'OG000'}]}]}, {'title': 'Improvement Noticed: Improvement in wrinkles', 'categories': [{'measurements': [{'value': '2', 'groupId': 'OG000'}]}]}, {'title': 'Improvement Noticed: Less sagging skin', 'categories': [{'measurements': [{'value': '5', 'groupId': 'OG000'}]}]}, {'title': 'Improvement Noticed: Smoother skin texture', 'categories': [{'measurements': [{'value': '3', 'groupId': 'OG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'timeFrame': 'Day 180, Day 270, Day 365', 'description': 'The subject will complete a Patient Satisfaction Questionnaire (PSQ)', 'unitOfMeasure': 'Participants', 'reportingStatus': 'POSTED'}, {'type': 'SECONDARY', 'title': 'Energy Delivered', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Renuvion APR System Treatment', 'description': 'Subjects are receiving treatment with the Renuvion APR system following power-assisted liposuction in the abdomen per investigator standard of care. Subjects may also have other body areas treated at the same time.\n\nRenuvion APR Handpiece: The Renuvion® APR (Apyx Plasma/RF) handpiece is a sterile, single use electrosurgical (monopolar) device intended to be used in conjunction with a compatible generator for the delivery of radiofrequency energy and helium plasma for cutting, coagulation and ablation of soft tissue during open surgical procedures. Radiofrequency energy is delivered to the handpiece by the generator and used to energize the electrode. When helium gas is passed over the energized electrode, a helium plasma is generated for cutting, coagulation or ablation of soft tissue during open surgical procedures. The compatible generators operate at an adjustable power of up to 40 W (expressed as 0 - 100% where 100% is 40 W) and provide an adjustable helium gas flow of 1 - 5 L/Min. APR Handpiece has a non-extendable electrode to generate helium plasma.'}], 'classes': [{'categories': [{'measurements': [{'value': '0.037', 'spread': '0.012', 'groupId': 'OG000'}]}]}], 'paramType': 'MEAN', 'timeFrame': 'Day 0', 'description': "Analysis of Energy per surface area was completed for all 5 subjects representing how much energy was delivered to each square centimeter of the abdomen's surface. The general pattern is that the energy per surface area decreases as the surface area of the abdomen increases. Analysis of energy delivered (kJ/cm2)", 'unitOfMeasure': 'kJ/cm2', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED'}]}, 'participantFlowModule': {'groups': [{'id': 'FG000', 'title': 'Renuvion APR System Treatment', 'description': 'Subjects are receiving treatment with the Renuvion APR system following power-assisted liposuction in the abdomen per investigator standard of care. Subjects may also have other body areas treated at the same time.\n\nRenuvion APR Handpiece: The Renuvion® APR (Apyx Plasma/RF) handpiece is a sterile, single use electrosurgical (monopolar) device intended to be used in conjunction with a compatible generator for the delivery of radiofrequency energy and helium plasma for cutting, coagulation and ablation of soft tissue during open surgical procedures. Radiofrequency energy is delivered to the handpiece by the generator and used to energize the electrode. When helium gas is passed over the energized electrode, a helium plasma is generated for cutting, coagulation or ablation of soft tissue during open surgical procedures. The compatible generators operate at an adjustable power of up to 40 W (expressed as 0 - 100% where 100% is 40 W) and provide an adjustable helium gas flow of 1 - 5 L/Min. APR Handpiece has a non-extendable electrode to generate helium plasma.'}], 'periods': [{'title': 'Overall Study', 'milestones': [{'type': 'STARTED', 'achievements': [{'comment': 'The first study subject was treated on June 12, 2023.', 'groupId': 'FG000', 'numSubjects': '5'}]}, {'type': 'COMPLETED', 'achievements': [{'comment': 'The last subject was treated on September 13, 2023.', 'groupId': 'FG000', 'numSubjects': '5'}]}, {'type': 'NOT COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '0'}]}]}]}, 'baselineCharacteristicsModule': {'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'BG000'}]}], 'groups': [{'id': 'BG000', 'title': 'Renuvion APR System Treatment', 'description': 'Subjects are receiving treatment with the Renuvion APR system following power-assisted liposuction in the abdomen per investigator standard of care. Subjects may also have other body areas treated at the same time.\n\nRenuvion APR Handpiece: The Renuvion® APR (Apyx Plasma/RF) handpiece is a sterile, single use electrosurgical (monopolar) device intended to be used in conjunction with a compatible generator for the delivery of radiofrequency energy and helium plasma for cutting, coagulation and ablation of soft tissue during open surgical procedures. Radiofrequency energy is delivered to the handpiece by the generator and used to energize the electrode. When helium gas is passed over the energized electrode, a helium plasma is generated for cutting, coagulation or ablation of soft tissue during open surgical procedures. The compatible generators operate at an adjustable power of up to 40 W (expressed as 0 - 100% where 100% is 40 W) and provide an adjustable helium gas flow of 1 - 5 L/Min. APR Handpiece has a non-extendable electrode to generate helium plasma.'}], 'measures': [{'title': 'Age, Categorical', 'classes': [{'categories': [{'title': '<=18 years', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Between 18 and 65 years', 'measurements': [{'value': '5', 'groupId': 'BG000'}]}, {'title': '>=65 years', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Age, Continuous', 'classes': [{'categories': [{'measurements': [{'value': '48', 'spread': '44', 'groupId': 'BG000'}]}]}], 'paramType': 'MEDIAN', 'unitOfMeasure': 'Years', 'dispersionType': 'STANDARD_DEVIATION'}, {'title': 'Sex: Female, Male', 'classes': [{'categories': [{'title': 'Female', 'measurements': [{'value': '4', 'groupId': 'BG000'}]}, {'title': 'Male', 'measurements': [{'value': '1', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Ethnicity (NIH/OMB)', 'classes': [{'categories': [{'title': 'Hispanic or Latino', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Not Hispanic or Latino', 'measurements': [{'value': '5', 'groupId': 'BG000'}]}, {'title': 'Unknown or Not Reported', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Race (NIH/OMB)', 'classes': [{'categories': [{'title': 'American Indian or Alaska Native', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Asian', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Native Hawaiian or Other Pacific Islander', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Black or African American', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'White', 'measurements': [{'value': '5', 'groupId': 'BG000'}]}, {'title': 'More than one race', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Unknown or Not Reported', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Region of Enrollment', 'classes': [{'title': 'United States', 'categories': [{'measurements': [{'value': '5', 'groupId': 'BG000'}]}]}], 'paramType': 'NUMBER', 'unitOfMeasure': 'participants'}, {'title': 'BMI', 'classes': [{'categories': [{'measurements': [{'value': '30.8', 'groupId': 'BG000', 'lowerLimit': '24.55', 'upperLimit': '36.61'}]}]}], 'paramType': 'MEAN', 'unitOfMeasure': 'kg/m2', 'dispersionType': 'FULL_RANGE'}]}}, 'documentSection': {'largeDocumentModule': {'largeDocs': [{'date': '2023-05-23', 'size': 832576, 'label': 'Study Protocol and Statistical Analysis Plan', 'hasIcf': False, 'hasSap': True, 'filename': 'Prot_SAP_000.pdf', 'typeAbbrev': 'Prot_SAP', 'uploadDate': '2024-11-13T08:47', 'hasProtocol': True}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'TREATMENT', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 5}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2023-06-01', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2025-01', 'completionDateStruct': {'date': '2024-09-30', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2025-01-28', 'studyFirstSubmitDate': '2023-07-05', 'resultsFirstSubmitDate': '2024-12-02', 'studyFirstSubmitQcDate': '2023-07-27', 'lastUpdatePostDateStruct': {'date': '2025-02-03', 'type': 'ACTUAL'}, 'resultsFirstSubmitQcDate': '2025-01-28', 'studyFirstPostDateStruct': {'date': '2023-08-01', 'type': 'ACTUAL'}, 'resultsFirstPostDateStruct': {'date': '2025-02-03', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2024-09-30', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Analysis of Contraction From Baseline to Day 365', 'timeFrame': 'Baseline, Day 365', 'description': "Percentage of soft tissue contraction measured by an ultrasonographer on baseline ultrasound images compared to follow-up images to quantify the total amount of connective tissue contraction produced by the Renuvion treatment between the skin and the Scarpa's fascia. A negative value indicates greater tissue contraction, while a positive value indicates less tissue contraction."}], 'secondaryOutcomes': [{'measure': 'IPR Review', 'timeFrame': 'Day 365', 'description': 'Three experienced, blinded photographic reviewers performed a qualitative analysis/review of pre-treatment and post-treatment sets of images at 90-days, 180-days, 270-days, and 365-days post-treatment compared to baseline for each subject. Images were provided in a blinded and randomized order. Each blinded reviewer choose which set of images were the post-treated Renuvion images of the abdomen. Success was the correct identification of treated abdomen images by at least 2 of the 3 reviewers.'}, {'measure': 'Physician Global Aesthetic Improvement', 'timeFrame': 'Day 60, Day 90, Day 180, Day 270, Day 365', 'description': 'The Principal Investigator, sub-investigator or qualified clinician delegated by the principal investigator, will complete a PGAIS assessing overall aesthetic improvement in the treatment area.'}, {'measure': 'Subject Global Aesthetic Improvement', 'timeFrame': 'Day 60, Day 90, Day 180, Day 270, Day 365', 'description': 'The subject will complete a SGAIS assessing overall aesthetic improvement in the treatment area.'}, {'measure': 'Patient Satisfaction', 'timeFrame': 'Day 180, Day 270, Day 365', 'description': 'The subject will complete a Patient Satisfaction Questionnaire (PSQ)'}, {'measure': 'Energy Delivered', 'timeFrame': 'Day 0', 'description': "Analysis of Energy per surface area was completed for all 5 subjects representing how much energy was delivered to each square centimeter of the abdomen's surface. The general pattern is that the energy per surface area decreases as the surface area of the abdomen increases. Analysis of energy delivered (kJ/cm2)"}]}, 'oversightModule': {'isUsExport': False, 'oversightHasDmc': False, 'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': True}, 'conditionsModule': {'keywords': ['Renuvion', 'Helium Plasma'], 'conditions': ['Skin Laxity']}, 'descriptionModule': {'briefSummary': 'This is a prospective, single-center, non-randomized study of up to 5 subjects who are receiving treatment with the Renuvion APR system following power-assisted liposuction in the abdomen per investigator standard of care. Ultrasound images of soft tissue contraction will be taken on abdomen prior to and during the procedure. Measurements of contraction will be calculated from the ultrasound images by an ultrasonographer. All adverse events and expected treatment effects will be documented.\n\nFollow-up photographs and ultrasound images will be captured at D30, D45, D60, D90, D180, D270, \\& D365.', 'detailedDescription': 'This is a prospective, single-center, non-randomized study of up to 5 subjects who are receiving treatment with the Renuvion APR system following power-assisted liposuction in the abdomen per investigator standard of care. Subjects may also have other body areas treated at the same time. Demographic information, medical history, and procedure details will be documented. Pre- and post-procedure care are per investigator standard of care and documented. Video may be taken during the procedure.\n\nUltrasound images of soft tissue contraction will be taken on abdomen prior to and during the procedure. Measurements of contraction will be calculated from the ultrasound images by an ultrasonographer. At baseline, photographs will be taken of the treatment areas. Surface area measurements will be taken of each treatment area prior to study treatment.\n\nPost-procedure care will be as per investigator standard of care and documented. All adverse events and expected treatment effects will be documented.\n\nFollow-up photographs and ultrasound images will be captured at D30, D45, D60, D90, D180, D270, \\& D365.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'maximumAge': '65 Years', 'minimumAge': '18 Years', 'healthyVolunteers': True, 'eligibilityCriteria': "Inclusion Criteria:\n\n* Patients who are scheduled for a procedure involving the use of Renuvion for the contraction of subcutaneous soft tissue. Patients undergoing procedures involving Renuvion alone and/or Renuvion following liposuction will be included.\n* Patients who have acceptable cardiopulmonary health for outpatient surgery.\n* Willing and able to comply with protocol requirements, including obtaining study-required images/photos and assessments, and returning for follow-up visits.\n* Willing to release rights for the use of study photos, including in potential publication.\n* Able to communicate with the site via video and/or photographs, in the event of a virtual follow-up visit.\n* Able to read, understand, sign and date the informed consent document (English only).\n\nExclusion Criteria:\n\n* BMI of greater than 35.\n* Diabetes mellitus with A1C score \\>7.\n* Active cigarette smokers or nicotine vape users.\n* History of connective tissue disease (Ehlers Danlos, Cutis Laxa, Pseudoxanthoma Elasticum, Marfan's, etc.)\n* Patients who, in the opinion of the investigator, is not an appropriate candidate for the study.\n* Patients requiring a concomitant procedure in the Renuvion treatment area that could impact the ultrasound measurements or the effectiveness results."}, 'identificationModule': {'nctId': 'NCT05968495', 'briefTitle': 'Measuring Renuvion Soft Tissue Contraction Using Ultrasound', 'organization': {'class': 'INDUSTRY', 'fullName': 'Apyx Medical'}, 'officialTitle': 'Measuring Renuvion Soft Tissue Contraction Using Ultrasound', 'orgStudyIdInfo': {'id': 'APX-23-02'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Renuvion APR System Treatment', 'description': 'Subjects are receiving treatment with the Renuvion APR system following power-assisted liposuction in the abdomen per investigator standard of care. Subjects may also have other body areas treated at the same time.', 'interventionNames': ['Device: Renuvion APR Handpiece']}], 'interventions': [{'name': 'Renuvion APR Handpiece', 'type': 'DEVICE', 'description': 'The Renuvion® APR (Apyx Plasma/RF) handpiece is a sterile, single use electrosurgical (monopolar) device intended to be used in conjunction with a compatible generator for the delivery of radiofrequency energy and helium plasma for cutting, coagulation and ablation of soft tissue during open surgical procedures. Radiofrequency energy is delivered to the handpiece by the generator and used to energize the electrode. When helium gas is passed over the energized electrode, a helium plasma is generated for cutting, coagulation or ablation of soft tissue during open surgical procedures. The compatible generators operate at an adjustable power of up to 40 W (expressed as 0 - 100% where 100% is 40 W) and provide an adjustable helium gas flow of 1 - 5 L/Min. APR Handpiece has a non-extendable electrode to generate helium plasma.', 'armGroupLabels': ['Renuvion APR System Treatment']}]}, 'contactsLocationsModule': {'locations': [{'zip': '98501', 'city': 'Olympia', 'state': 'Washington', 'country': 'United States', 'facility': 'Pearl Plastic Surgery', 'geoPoint': {'lat': 47.04491, 'lon': -122.90169}}], 'overallOfficials': [{'name': 'Chris Nichols', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Investigator'}, {'name': 'Dan Albershardt', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Investigator'}]}, 'ipdSharingStatementModule': {'ipdSharing': 'NO'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Apyx Medical', 'class': 'INDUSTRY'}, 'responsibleParty': {'type': 'SPONSOR'}}}}