Viewing Study NCT06893367


Ignite Creation Date: 2025-12-25 @ 12:27 AM
Ignite Modification Date: 2025-12-25 @ 10:32 PM
Study NCT ID: NCT06893367
Status: NOT_YET_RECRUITING
Last Update Posted: 2025-03-25
First Post: 2025-03-06
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Reliability of Sensor-Derived Measurements of the SENSorized Fugl-Meyer (FMA) in Subjects with Stroke Outcomes
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D020521', 'term': 'Stroke'}], 'ancestors': [{'id': 'D002561', 'term': 'Cerebrovascular Disorders'}, {'id': 'D001927', 'term': 'Brain Diseases'}, {'id': 'D002493', 'term': 'Central Nervous System Diseases'}, {'id': 'D009422', 'term': 'Nervous System Diseases'}, {'id': 'D014652', 'term': 'Vascular Diseases'}, {'id': 'D002318', 'term': 'Cardiovascular Diseases'}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'OTHER', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ESTIMATED', 'count': 50}}, 'statusModule': {'overallStatus': 'NOT_YET_RECRUITING', 'startDateStruct': {'date': '2025-05', 'type': 'ESTIMATED'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2025-03', 'completionDateStruct': {'date': '2026-05', 'type': 'ESTIMATED'}, 'lastUpdateSubmitDate': '2025-03-18', 'studyFirstSubmitDate': '2025-03-06', 'studyFirstSubmitQcDate': '2025-03-18', 'lastUpdatePostDateStruct': {'date': '2025-03-25', 'type': 'ACTUAL'}, 'studyFirstPostDateStruct': {'date': '2025-03-25', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2026-05', 'type': 'ESTIMATED'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Participants assessed by IMU', 'timeFrame': 'baseline', 'description': 'The Fugl-Meyer Assessment (FMA) is obtained with IMU and RealSense cameras.\n\nBelow are the individual items of the FMA that will be acquired via the experimental kit:\n\n* A II. Voluntary movement in synergy: flexor synergy/extensor synergy\n* A III. Voluntary movement with mixed synergies: hand to lumbar spine/shoulder flexion 0- 90/pronation-supination\n* A IV. Voluntary movement with reduced or absent synergy: shoulder abduction 0-90/shoulder flexion 90-180/pronation-supination\n* B I. Wrist: stability at 15° dorsiflexion with elbow 90°\n* B II. Wrist: repeated dorsiflexion with elbow 90°\n* B III. Wrist: Stability at 15° dorsiflexion with elbow at 0°\n* B IV. Wrist: repeated dorsiflexion with elbow at 0°\n* D. Coordination/Speed: tremor\n* D. Coordination/Speed: dysmetria\n* D. Coordination/Speed: time'}, {'measure': 'Participants assessed by IMU', 'timeFrame': 'at least 15 min from baseline', 'description': 'The Fugl-Meyer Assessment (FMA) is obtained with IMU and RealSense cameras.\n\nBelow are the individual items of the FMA that will be acquired via the experimental kit:\n\n* A II. Voluntary movement in synergy: flexor synergy/extensor synergy\n* A III. Voluntary movement with mixed synergies: hand to lumbar spine/shoulder flexion 0- 90/pronation-supination\n* A IV. Voluntary movement with reduced or absent synergy: shoulder abduction 0-90/shoulder flexion 90-180/pronation-supination\n* B I. Wrist: stability at 15° dorsiflexion with elbow 90°\n* B II. Wrist: repeated dorsiflexion with elbow 90°\n* B III. Wrist: Stability at 15° dorsiflexion with elbow at 0°\n* B IV. Wrist: repeated dorsiflexion with elbow at 0°\n* D. Coordination/Speed: tremor\n* D. Coordination/Speed: dysmetria\n* D. Coordination/Speed: time'}, {'measure': 'Participants assessed by IMU', 'timeFrame': 'at least 30 min from baseline', 'description': 'The Fugl-Meyer Assessment (FMA) is obtained with IMU and RealSense cameras.\n\nBelow are the individual items of the FMA that will be acquired via the experimental kit:\n\n* A II. Voluntary movement in synergy: flexor synergy/extensor synergy\n* A III. Voluntary movement with mixed synergies: hand to lumbar spine/shoulder flexion 0- 90/pronation-supination\n* A IV. Voluntary movement with reduced or absent synergy: shoulder abduction 0-90/shoulder flexion 90-180/pronation-supination\n* B I. Wrist: stability at 15° dorsiflexion with elbow 90°\n* B II. Wrist: repeated dorsiflexion with elbow 90°\n* B III. Wrist: Stability at 15° dorsiflexion with elbow at 0°\n* B IV. Wrist: repeated dorsiflexion with elbow at 0°\n* D. Coordination/Speed: tremor\n* D. Coordination/Speed: dysmetria\n* D. Coordination/Speed: time'}], 'secondaryOutcomes': [{'measure': 'Total FMA score', 'timeFrame': 'baseline', 'description': 'Sensorimotor recovery assessment after stroke, total score from 0 to 64, subscore upper limb 36, lower limb 28. Higher scores represent better outcomes.'}, {'measure': 'MODIFIED BARTHEL INDEX (mBI)', 'timeFrame': 'baseline', 'description': "The Modified Barthel Index (MBI) is a tool used to assess a person's level of independence in performing activities of daily living, particularly in geriatrics and rehabilitation settings. It consists of 10 activities, such as eating, dressing, using the bathroom, moving around, and personal hygiene, each assigned a specific score. A higher score indicates greater independence, while a lower score reflects a higher level of dependence on assistance. The modified version of the Barthel Index is adapted from the original and is commonly used to track progress during rehabilitation or for patients with disabilities."}]}, 'oversightModule': {'isUsExport': False, 'oversightHasDmc': False, 'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': False}, 'conditionsModule': {'conditions': ['Stroke', 'Sensorimotor Impairment Affecting the Upper Limb', '18 Years and Over']}, 'descriptionModule': {'briefSummary': 'This study will be conducted at a single research center, the main objective of the study will be to evaluate the efficacy, safety, and accuracy of a medical device that has not yet been commercialized; therefore, it is still under development or testing and is not yet available for private use and is not for profit (nonprofit).\n\nFifty participants will be recruited from subjects afferent to the outpatient and inpatient neuro-motor rehabilitation clinics of IRCCS Fondazione Don Carlo Gnocchi in Florence, Italy, and afferent to the outpatient and inpatient rehabilitation clinics of Elias University Emergency Hospital in Bucharest, Romania.\n\nIn detail, it is deemed necessary to collect clinical and instrumental data. The study will be conducted by an interdisciplinary team composed of healthcare professionals and engineers afferent to the Department of Industrial Engineering.\n\nShould you decide to participate in the study, a visit to verify the inclusion and exclusion criteria will be primarily conducted. Once the admission criteria have been verified, participants will undergo a series of assessments.\n\nThe first, involves the administration of some specific sections of the Fugl-Meyer scale (FMA), focusing on the upper extremities. Specifically, the following will be examined: section A for general upper limb function, section B assessing wrist mobility, and finally section D for limb coordination and speed.\n\nDuring this phase, both upper limbs will be assessed, in addition, the first examiner will carefully place sensors on the participants and assign scores to the tests performed, according to the criteria established by the FMA scale.\n\nNext, a second assessment (T1) will be conducted, in which a second examiner will be responsible for placing the sensors and recording data only on the most affected side.\n\nAt a third time, called "T2" and again with at least 15 minutes interval from T1, the first examiner will repeat the same assessments performed in "T1." While performing these assessments, a RealSense camera will be used.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '18 Years', 'healthyVolunteers': False, 'eligibilityCriteria': "Inclusion Criteria:\n\n* age 18 years or older;\n* stroke outcomes with the presence of sensorimotor impairment in the upper limb;\n* willingness to participate in the project, with informed consent signed by the person himself or, when necessary, by the support administrator/legal guardian.\n\nExclusion Criteria:\n\n* Severe concomitant pathologies that modify the subject's motor framework;\n* severe visual and/or hearing impairments that cannot be corrected;\n* severe neuropsychological impairments (aphasia, apraxia, other cognitive deficits ) such as to prevent cooperation in administering the scale;\n* presence of signs of clinical instability, defined by a score greater than zero on the SIC scale (Clinical Instability Scale)."}, 'identificationModule': {'nctId': 'NCT06893367', 'acronym': 'FMA-SENS', 'briefTitle': 'Reliability of Sensor-Derived Measurements of the SENSorized Fugl-Meyer (FMA) in Subjects with Stroke Outcomes', 'organization': {'class': 'OTHER', 'fullName': 'Fondazione Don Carlo Gnocchi Onlus'}, 'officialTitle': 'Reliability of Sensor-Derived Measurements of the SENSorized Fugl-Meyer (FMA) in Subjects with Stroke Outcomes', 'orgStudyIdInfo': {'id': 'FMA-SENS'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Stroke group', 'description': 'each participant will perform the FMA with IMU', 'interventionNames': ['Device: IMU and RealSense Cameras']}], 'interventions': [{'name': 'IMU and RealSense Cameras', 'type': 'DEVICE', 'description': 'Each participant will perform the FMA-sens, with their most affected hand, followed by the FMA-sens with the less affected hand.', 'armGroupLabels': ['Stroke group']}]}, 'contactsLocationsModule': {'locations': [{'city': 'Florence', 'country': 'Italy', 'contacts': [{'name': 'Francesca Cecchi', 'role': 'CONTACT', 'email': 'fcecchi@dongnocchi.it', 'phone': '055/73931'}], 'facility': 'IRCCS Fondazione Don Carlo Gnocchi, Firenze', 'geoPoint': {'lat': 43.77925, 'lon': 11.24626}}], 'centralContacts': [{'name': 'Francesca Cecchi', 'role': 'CONTACT', 'email': 'fcecchi@dongnocchi.it', 'phone': '055/73931'}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Fondazione Don Carlo Gnocchi Onlus', 'class': 'OTHER'}, 'collaborators': [{'name': 'University of Florence', 'class': 'OTHER'}, {'name': 'University of Bucharest', 'class': 'OTHER'}], 'responsibleParty': {'type': 'SPONSOR'}}}}