Viewing Study NCT03279458


Ignite Creation Date: 2025-12-25 @ 12:14 AM
Ignite Modification Date: 2026-01-05 @ 10:52 PM
Study NCT ID: NCT03279458
Status: COMPLETED
Last Update Posted: 2018-07-05
First Post: 2017-09-06
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: Non-invasive Tidal Volume Monitoring Using the Linshom Respiratory Monitoring Device
Sponsor:
Organization:

Raw JSON

{'hasResults': True, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'resultsSection': {'moreInfoModule': {'pointOfContact': {'email': 'msathyamoorthy@umc.edu', 'phone': '6018157066', 'title': 'Dr. Madhankumar Sathyamoorthy, Principal Investigator', 'organization': 'University of Mississippi Medical Center'}, 'certainAgreement': {'piSponsorEmployee': True, 'restrictiveAgreement': False}}, 'adverseEventsModule': {'timeFrame': 'Adverse event data was collected for approximately 30 minutes, including the time while the patient was using the mask and the time immediately after completing the study.', 'eventGroups': [{'id': 'EG000', 'title': 'Linshom', 'description': 'Linshom Respiratory Monitoring Device: Volunteers will breathe through a continuous positive airway pressure (CPAP) face mask fitted wth the Linshom device. The volunteers will be instructed to breathe normal through the CPAP mask on room air. The excursions of the thermistor tracings (from valley to peak) will be recorded by the Linshom device and displayed continuously on a laptop monitor in a waveform.', 'otherNumAtRisk': 40, 'deathsNumAtRisk': 40, 'otherNumAffected': 0, 'seriousNumAtRisk': 40, 'deathsNumAffected': 0, 'seriousNumAffected': 0}, {'id': 'EG001', 'title': 'Maquet Ventilator', 'description': 'The tidal volume will also be measured by the maquet ventilatorconcurrently and the data downloaded in a Compact Flash card.', 'otherNumAtRisk': 40, 'deathsNumAtRisk': 40, 'otherNumAffected': 0, 'seriousNumAtRisk': 40, 'deathsNumAffected': 0, 'seriousNumAffected': 0}], 'frequencyThreshold': '0'}, 'outcomeMeasuresModule': {'outcomeMeasures': [{'type': 'PRIMARY', 'title': 'Tidal Volume of Each Breath Was Measured Using the Same Breathing Mask CPAP Apparatus Combined With Respiratory Monitoring Device Allowing for Simultaneous Recording.', 'denoms': [{'units': 'Participants', 'counts': [{'value': '30', 'groupId': 'OG000'}, {'value': '30', 'groupId': 'OG001'}]}], 'groups': [{'id': 'OG000', 'title': 'Linshom', 'description': 'Linshom Respiratory Monitoring Device: Volunteers will breathe through a continuous positive airway pressure (CPAP) face mask fitted wth the Linshom device. The volunteers will be instructed to breathe normal through the CPAP mask on room air. The excursions of the thermistor tracings (from valley to peak) will be recorded by the Linshom device and displayed continuously on a laptop monitor in a waveform. The tidal volume will also be measured by the ventilator and the data downloaded in a Compact Flash card.'}, {'id': 'OG001', 'title': 'Maquet Ventilator', 'description': 'Tidal volume measured by the Maquet ventilator connected to CPAP mask concurrently with Linshom'}], 'classes': [{'categories': [{'measurements': [{'value': '0.94', 'groupId': 'OG000', 'lowerLimit': '0.88', 'upperLimit': '0.97'}, {'value': '0.94', 'groupId': 'OG001', 'lowerLimit': '0.88', 'upperLimit': '0.97'}]}]}], 'analyses': [{'pValue': '<0.05', 'groupIds': ['OG000', 'OG001'], 'paramType': 'correlation coefficient (R)', 'ciNumSides': 'TWO_SIDED', 'ciPctValue': '95', 'paramValue': '0.94', 'ciLowerLimit': '0.88', 'ciUpperLimit': '0.97', 'statisticalMethod': 'Regression, Linear', 'nonInferiorityType': 'OTHER', 'nonInferiorityComment': 'least square regression analysis'}], 'paramType': 'LEAST_SQUARES_MEAN', 'timeFrame': '5 minutes', 'description': 'Tidal volume measured by CPAP mask with Lishom respiratory monitoring device. Tidal volume determined from the ventilator will be compared to tidal volume measured by Linshom (calculated indirectly by temperature changes by computer algorithm)', 'unitOfMeasure': 'ml', 'dispersionType': '95% Confidence Interval', 'reportingStatus': 'POSTED', 'populationDescription': 'Thirty participants successfully completed the experiment, which involved breathing through a CPAP mask in order to have the Linshom device record excursions of the thermistor tracings while the ventilator concurrently measured tidal volume.'}]}, 'participantFlowModule': {'groups': [{'id': 'FG000', 'title': 'Linshom Respiratory Monitoring Device', 'description': 'Volunteers will breathe through a continuous positive airway pressure (CPAP) face mask fitted with the Linshom device. The volunteers will be instructed to breathe normal through the CPAP mask on room air. The excursions of the thermistor tracings (from valley to peak) will be recorded by the Linshom device and displayed continuously on a laptop monitor in a waveform. The tidal volume will also be measured by the ventilator and the data downloaded in a Compact Flash card.'}], 'periods': [{'title': 'Overall Study', 'milestones': [{'type': 'STARTED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '40'}]}, {'type': 'COMPLETED', 'comment': 'The milestone was met if the participant was able to complete the breathing exercise.', 'achievements': [{'groupId': 'FG000', 'numSubjects': '40'}]}, {'type': 'NOT COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '0'}]}]}]}, 'baselineCharacteristicsModule': {'denoms': [{'units': 'Participants', 'counts': [{'value': '40', 'groupId': 'BG000'}]}], 'groups': [{'id': 'BG000', 'title': 'Linshom', 'description': 'Linshom Respiratory Monitoring Device: Volunteers will breathe through a continuous positive airway pressure (CPAP) face mask fitted wth the Linshom device. The volunteers will be instructed to breathe normal through the CPAP mask on room air. The excursions of the thermistor tracings (from valley to peak) will be recorded by the Linshom device and displayed continuously on a laptop monitor in a waveform. The tidal volume will also be measured by the ventilator and the data downloaded in a Compact Flash card.'}], 'measures': [{'title': 'Age, Customized', 'classes': [{'title': '>= 18 years', 'denoms': [{'units': 'Participants', 'counts': [{'value': '40', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '40', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Sex: Female, Male', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '0', 'groupId': 'BG000'}]}], 'categories': [{'title': 'Female'}, {'title': 'Male'}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants', 'populationDescription': 'The sex of participants was not collected.'}, {'title': 'Race and Ethnicity Not Collected', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '0', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants', 'populationDescription': 'Race and Ethnicity were not collected from any participant.'}, {'title': 'Region of Enrollment', 'classes': [{'title': 'United States', 'denoms': [{'units': 'Participants', 'counts': [{'value': '40', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '40', 'groupId': 'BG000'}]}]}], 'paramType': 'NUMBER', 'unitOfMeasure': 'participants'}, {'title': 'Number of participants', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '40', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '40', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}]}}, 'documentSection': {'largeDocumentModule': {'largeDocs': [{'date': '2017-06-21', 'size': 638064, 'label': 'Study Protocol and Statistical Analysis Plan', 'hasIcf': False, 'hasSap': True, 'filename': 'Prot_SAP_001.pdf', 'typeAbbrev': 'Prot_SAP', 'uploadDate': '2018-03-30T14:25', 'hasProtocol': True}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NON_RANDOMIZED', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'DIAGNOSTIC', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 40}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2017-09-08', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2018-07', 'completionDateStruct': {'date': '2017-09-08', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2018-07-03', 'studyFirstSubmitDate': '2017-09-06', 'resultsFirstSubmitDate': '2017-10-24', 'studyFirstSubmitQcDate': '2017-09-08', 'lastUpdatePostDateStruct': {'date': '2018-07-05', 'type': 'ACTUAL'}, 'resultsFirstSubmitQcDate': '2018-07-03', 'studyFirstPostDateStruct': {'date': '2017-09-12', 'type': 'ACTUAL'}, 'resultsFirstPostDateStruct': {'date': '2018-07-05', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2017-09-08', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Tidal Volume of Each Breath Was Measured Using the Same Breathing Mask CPAP Apparatus Combined With Respiratory Monitoring Device Allowing for Simultaneous Recording.', 'timeFrame': '5 minutes', 'description': 'Tidal volume measured by CPAP mask with Lishom respiratory monitoring device. Tidal volume determined from the ventilator will be compared to tidal volume measured by Linshom (calculated indirectly by temperature changes by computer algorithm)'}]}, 'oversightModule': {'isUsExport': False, 'oversightHasDmc': False, 'isFdaRegulatedDrug': False, 'isUnapprovedDevice': True, 'isFdaRegulatedDevice': True}, 'conditionsModule': {'keywords': ['Capnography'], 'conditions': ['Pulmonary Ventilation', 'Capnography']}, 'referencesModule': {'references': [{'pmid': '23871325', 'type': 'BACKGROUND', 'citation': 'Manifold CA, Davids N, Villers LC, Wampler DA. Capnography for the nonintubated patient in the emergency setting. J Emerg Med. 2013 Oct;45(4):626-32. doi: 10.1016/j.jemermed.2013.05.012. Epub 2013 Jul 18.'}, {'pmid': '3625404', 'type': 'BACKGROUND', 'citation': 'Brouillette RT, Morrow AS, Weese-Mayer DE, Hunt CE. Comparison of respiratory inductive plethysmography and thoracic impedance for apnea monitoring. J Pediatr. 1987 Sep;111(3):377-83. doi: 10.1016/s0022-3476(87)80457-2.'}, {'pmid': '23632055', 'type': 'BACKGROUND', 'citation': 'Ramsay MA, Usman M, Lagow E, Mendoza M, Untalan E, De Vol E. The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic monitoring and capnometry. Anesth Analg. 2013 Jul;117(1):69-75. doi: 10.1213/ANE.0b013e318290c798. Epub 2013 Apr 30.'}, {'pmid': '18676546', 'type': 'BACKGROUND', 'citation': 'Keidan I, Gravenstein D, Berkenstadt H, Ziv A, Shavit I, Sidi A. Supplemental oxygen compromises the use of pulse oximetry for detection of apnea and hypoventilation during sedation in simulated pediatric patients. Pediatrics. 2008 Aug;122(2):293-8. doi: 10.1542/peds.2007-2385.'}, {'pmid': '8273874', 'type': 'BACKGROUND', 'citation': 'Williamson JA, Webb RK, Cockings J, Morgan C. The Australian Incident Monitoring Study. The capnograph: applications and limitations--an analysis of 2000 incident reports. Anaesth Intensive Care. 1993 Oct;21(5):551-7. doi: 10.1177/0310057X9302100510.'}, {'pmid': '17893118', 'type': 'BACKGROUND', 'citation': 'Nassi N, Piumelli R, Lombardi E, Landini L, Donzelli G, de Martino M. Comparison between pulse oximetry and transthoracic impedance alarm traces during home monitoring. Arch Dis Child. 2008 Feb;93(2):126-32. doi: 10.1136/adc.2007.118513. Epub 2007 Sep 24.'}, {'pmid': '19672177', 'type': 'BACKGROUND', 'citation': 'Kasuya Y, Akca O, Sessler DI, Ozaki M, Komatsu R. Accuracy of postoperative end-tidal Pco2 measurements with mainstream and sidestream capnography in non-obese patients and in obese patients with and without obstructive sleep apnea. Anesthesiology. 2009 Sep;111(3):609-15. doi: 10.1097/ALN.0b013e3181b060b6.'}, {'pmid': '27412466', 'type': 'BACKGROUND', 'citation': 'Lerman J, Feldman D, Feldman R, Moser J, Feldman L, Sathyamoorthy M, Deitch K, Feldman U. Linshom respiratory monitoring device: a novel temperature-based respiratory monitor. Can J Anaesth. 2016 Oct;63(10):1154-1160. doi: 10.1007/s12630-016-0694-y. Epub 2016 Jul 13.'}], 'seeAlsoLinks': [{'url': 'http://www.asaabstracts.com/strands/asaabstracts/abstract.htm%20%20;jsessionid=682567A35143EC5A44D16DFEEE86493A?year=2015&index=8&absnum=4494', 'label': 'A thermodynamic breathing sensor - a new non-invasive monitor of respiration'}]}, 'descriptionModule': {'briefSummary': "Many post-operative complications arise from patients who breathe inadequately. Inadequate respiration, whether the result of surgery or the anesthesia, causes a decrease in blood oxygen saturation and an increase in carbon dioxide partial pressure. Both of these surrogate measurements of respiration may pose a challenge to measure. Some administer exogenous oxygen to all patients as they leave the operating room in order to maintain the blood oxygen saturation. This renders the oximeter a less sensitive metric of depressed respiration. In the face of decreased respiration, the carbon dioxide levels continue to increase slowly and often go undetected unless blood gases are measured. Indeed carbon dioxide blood levels are the only metric to detect inadequate ventilation using this surrogate index.\n\nMonitoring ventilation is a serious challenge outside of critical care settings. In fact, there are no monitors available that can measure tidal volume or relative tidal volume outside of these settings.\n\nLinshom is a novel instrument that tracks relative respiration by measuring the excursions of the temperature swings between inspiration and expiration and normalizing them to the patient's breathing. This monitor may be the first non-invasive monitor to measure relative tidal volume in non-critical care settings.\n\nThe purpose of this study is to determine whether a non-invasive, temperature-based respiratory instrument can track tidal volume (Vt) in patients.\n\nThe investigators hypothesize that the Linshom device can accurately and consistently track tidal volume as measured by closed loop mechanical ventilator.", 'detailedDescription': 'Forty volunteers will be enrolled in this open label, prospective study to determine the correlation between the tidal volumes measured with the Linshom detector and those measured with the mechanical ventilator. after Institutional Review Board (IRB) approval and written informed consent from the volunteers.\n\nThe Linshom detector, which is comprised of two rapid responding medical-grade thermistors in close proximity to the mouth/nose (sensor) and a thermistor remote to the airway, will be mounted in the continuous positive airway pressure (CPAP) face mask to measure the temperature during breathing. The CPAP will be connected to a Servo-I ventilator (Maquet) with a circuit and disposable filter. The volunteers will be instructed to breathe normal through the CPAP mask on room air. The excursions of the thermistor tracings (from valley to peak) will be recorded by the Linshom device and displayed continuously on a laptop monitor in a waveform. The tidal volume will also be measured by the ventilator and the data downloaded in a Compact Flash card. The temperature profiles from the sensors and the relative tidal volume will be correlated with the tidal volumes measured by the ventilator.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '18 Years', 'healthyVolunteers': True, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* healthy\n\nExclusion Criteria:\n\n* pregnant\n* suffer from claustrophobia\n* had recent respiratory illness\n* had recent gastrointestinal illness\n* unable to provide informed consent'}, 'identificationModule': {'nctId': 'NCT03279458', 'briefTitle': 'Non-invasive Tidal Volume Monitoring Using the Linshom Respiratory Monitoring Device', 'organization': {'class': 'OTHER', 'fullName': 'University of Mississippi Medical Center'}, 'officialTitle': 'Non-invasive Tidal Volume Monitoring Using the Linshom Respiratory Monitoring Device', 'orgStudyIdInfo': {'id': '2017-0063'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Linshom Respiratory Monitoring Device', 'description': 'Volunteers will breathe through a continuous positive airway pressure (CPAP) face mask fitted with the Linshom device. The volunteers will be instructed to breathe normal through the CPAP mask on room air. The excursions of the thermistor tracings (from valley to peak) will be recorded by the Linshom device and displayed continuously on a laptop monitor in a waveform.', 'interventionNames': ['Device: Linshom Respiratory Monitoring Device']}, {'type': 'ACTIVE_COMPARATOR', 'label': 'Ventilator', 'description': 'Volunteers will breathe through a continuous positive airway pressure (CPAP) face mask fitted with the Linshom device. The volunteers will be instructed to breathe normal through the CPAP mask on room air.The tidal volume will also be measured by the ventilator and the data downloaded in a Compact Flash card.', 'interventionNames': ['Device: Linshom Respiratory Monitoring Device']}], 'interventions': [{'name': 'Linshom Respiratory Monitoring Device', 'type': 'DEVICE', 'description': 'Volunteers will breathe through a continuous positive airway pressure (CPAP) face mask fitted wth the Linshom device. The volunteers will be instructed to breathe normal through the CPAP mask on room air. The excursions of the thermistor tracings (from valley to peak) will be recorded by the Linshom device and displayed continuously on a laptop monitor in a waveform. The tidal volume will also be measured by the ventilator and the data downloaded in a Compact Flash card.', 'armGroupLabels': ['Linshom Respiratory Monitoring Device', 'Ventilator']}]}, 'contactsLocationsModule': {'locations': [{'zip': '39216', 'city': 'Jackson', 'state': 'Mississippi', 'country': 'United States', 'facility': 'University of Mississippi Medical Center', 'geoPoint': {'lat': 32.29876, 'lon': -90.18481}}], 'overallOfficials': [{'name': 'Madhankumar Sathyamoorthy, MBBS, MS', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': "Children's of Mississippi/University of Mississippi Medical Center"}]}, 'ipdSharingStatementModule': {'ipdSharing': 'NO', 'description': 'No plan to share IPD'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'University of Mississippi Medical Center', 'class': 'OTHER'}, 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'Associate Professor', 'investigatorFullName': 'Madhankumar Sathyamoorthy', 'investigatorAffiliation': 'University of Mississippi Medical Center'}}}}