Viewing Study NCT05346458


Ignite Creation Date: 2025-12-25 @ 12:03 AM
Ignite Modification Date: 2026-01-01 @ 7:33 AM
Study NCT ID: NCT05346458
Status: COMPLETED
Last Update Posted: 2024-04-30
First Post: 2022-03-09
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Measuring Blood Flow in Heart Vessels With a New Fibre Optic Sensor
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D003324', 'term': 'Coronary Artery Disease'}, {'id': 'D023921', 'term': 'Coronary Stenosis'}, {'id': 'D017566', 'term': 'Microvascular Angina'}], 'ancestors': [{'id': 'D003327', 'term': 'Coronary Disease'}, {'id': 'D017202', 'term': 'Myocardial Ischemia'}, {'id': 'D006331', 'term': 'Heart Diseases'}, {'id': 'D002318', 'term': 'Cardiovascular Diseases'}, {'id': 'D001161', 'term': 'Arteriosclerosis'}, {'id': 'D001157', 'term': 'Arterial Occlusive Diseases'}, {'id': 'D014652', 'term': 'Vascular Diseases'}, {'id': 'D000787', 'term': 'Angina Pectoris'}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'DIAGNOSTIC', 'interventionModel': 'SINGLE_GROUP', 'interventionModelDescription': 'A single centre, prospective, feasibility study of the iKOs™ coronary pressure and flow rapid-exchange microcatheter and iKOr™ console in patients with coronary heart disease undergoing coronary physiology investigations.'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 10}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2022-12-14', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2024-04', 'completionDateStruct': {'date': '2023-10-03', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2024-04-29', 'studyFirstSubmitDate': '2022-03-09', 'studyFirstSubmitQcDate': '2022-04-19', 'lastUpdatePostDateStruct': {'date': '2024-04-30', 'type': 'ACTUAL'}, 'studyFirstPostDateStruct': {'date': '2022-04-26', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2023-08-22', 'type': 'ACTUAL'}}, 'outcomesModule': {'otherOutcomes': [{'measure': 'To examine the quality of the temperature recordings', 'timeFrame': 'Measured from just prior to adenosine administration (baseline), and during adenosine administration (hyperaemia).', 'description': 'The number of complete temperature measurement recordings and the number of interpretable temperature waveforms'}, {'measure': 'To examine ease of use of the iKOs microcatheter', 'timeFrame': 'Measured at procedure - the time taken from insertion of iKOs microcatheter into guide cath to removal of iKOs microcatheter from guide cath', 'description': 'Time taken for deployment of the microcatheter'}], 'primaryOutcomes': [{'measure': 'To assess the effectiveness of the iKOr system in measuring temperature change (flow) in patients with coronary artery disease undergoing physiology investigations', 'timeFrame': 'Measured immediately prior to adenosine administration (baseline), and during adenosine administration (hyperaemia).', 'description': 'A change in thermal transit time measured by the iKOr system'}], 'secondaryOutcomes': [{'measure': 'To assess the safety of the iKOs microcatheter in patients undergoing angiography and pressure wire assessment', 'timeFrame': 'Measured at procedure, at 4 hrs post procedure, at 1 week post procedure and 8 weeks post procedure', 'description': 'The number of major adverse cardiac events or patient deaths'}, {'measure': 'To assess the safety of the iKOs microcatheter procedure', 'timeFrame': 'Measured at procedure, 4 hrs post procedure, at 1 week post procedure and 8 weeks post procedure', 'description': 'The number of procedural complications related to the device (operator observed vessel spasm, vascular complications, bleeding)'}, {'measure': 'To assess the effect of the iKOs microcatheter on cardiac injury', 'timeFrame': 'Troponin T measurement at procedure start and 4 hrs post procedure', 'description': 'The change in Troponin levels'}, {'measure': 'To assess the effect of the iKOs microcatheter on TIMI (Thrombolysis In Myocardial Infarction) flow', 'timeFrame': 'TIMI flow measured immediately prior to insertion of iKOs microcatheter and on removal of the iKOs microcatheter', 'description': 'The change in TIMI (Thrombolysis In Myocardial Infarction) flow'}]}, 'oversightModule': {'oversightHasDmc': True, 'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': False}, 'conditionsModule': {'keywords': ['Heart', 'Microcatheter', 'Fibreoptic'], 'conditions': ['Coronary Artery Disease', 'Coronary Stenosis', 'Coronary Microvascular Disease']}, 'descriptionModule': {'briefSummary': 'The purpose of this investigation is to see if the newly developed "iKOs™ microcatheter" can safely and accurately measure flow and pressure within the heart arteries of 10 patients undergoing angiogram and pressure wire tests.', 'detailedDescription': 'After being informed about the study and the potential risks and benefits, participants who provide written consent will be screened to make sure they fulfil the study entry requirements. Those who are assessed as eligible will undergo baseline assessments and preparation for their angiogram.\n\nOnce enrolled they will undergo coronary angiography at the start of their clinical procedure. The angiogram will be examined by the Investigator and a decision made if the target vessel is suitable for a pressure wire study and insertion of the investigational device. If the investigator confirms that the participant remains eligible and the study part can go ahead, the participant will proceed to undergo the investigation with the iKOs microcatheter.\n\nThe study assessments will be performed through the right radial artery (preference) under local anaesthesia. A sheath will be inserted and a pre-procedure blood sample taken for Troponin T level. A pressure study will then be performed, initially with a pressure wire before using the iKOs™ microcatheter. Both will be performed before and after hyperaemia. Following withdrawal of the iKOs™ microcatheter, a pressure wire assessment is then repeated after the microcatheter is withdrawn. The case will then proceed as clinically indicated. The whole procedure should take about 30-45 minutes. Post-procedure the participant will be managed according to standard clinical practice.\n\nThe participant will be discharged home, usually about 4 hours after the end of the procedure. A troponin blood test and ECG will be repeated before they are discharged.\n\nFollow up telephone calls to assess for any complications of the procedure will be made within the first 7 days and again between 6 and 8 weeks after the procedure.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '18 Years', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Able and willing to give informed consent\n* \\>18 years old\n* Have a clinical diagnosis of coronary artery disease\n* Undergoing further assessment of a coronary artery with a pressure wire study\n\nExclusion Criteria:\n\nGeneral\n\n* Previous coronary artery bypass grafting.\n* Non/ST-elevation myocardial infarction as indication for angiography.\n* Ongoing evidence of ischaemia at rest.\n* Severe renal impairment (GFR \\<25).\n* Severe anaemia (Hb \\<10).\n* Heparin allergy.\n* Atrial fibrillation.\n* Contraindication to adenosine.\n* Pregnant or lactating; or female of childbearing potential.\n* Participation in other interventional studies.\n\nAdditional exclusion criteria at Angiogram:\n\n* Critical coronary artery stenosis in the vessel which is to be studied (\\>90%).\n* Left main stem coronary disease causing a \\>50% stenosis.\n* Triple vessel coronary disease.'}, 'identificationModule': {'nctId': 'NCT05346458', 'briefTitle': 'Measuring Blood Flow in Heart Vessels With a New Fibre Optic Sensor', 'organization': {'class': 'OTHER', 'fullName': 'Queen Mary University of London'}, 'officialTitle': 'A Single Centre, Prospective, Feasibility Study of the iKOs™ Coronary Pressure and Flow Rapid-exchange Microcatheter and iKOr™ Console in Patients With Coronary Heart Disease Undergoing Coronary Physiology Investigations', 'orgStudyIdInfo': {'id': '305877'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Intra coronary rapid-exchange iKOs microcatheter intervention', 'description': 'Patients with coronary heart disease and undergoing coronary physiology investigations (pressure wire measurements) will have additional coronary pressure and flow measurements using the iKOs rapid-exchange microcatheter and iKOr console.', 'interventionNames': ['Device: Intra coronary rapid-exchange iKOs microcatheter intervention']}], 'interventions': [{'name': 'Intra coronary rapid-exchange iKOs microcatheter intervention', 'type': 'DEVICE', 'otherNames': ['iKOs Microcatheter'], 'description': 'Patients planned for an invasive coronary physiology (pressure-wire) study and who meet the inclusion criteria and none of the exclusion criteria can be enrolled. Participants will undergo preparation for their clinical procedure (angiogram with pressure wire study) in the normal manner. Arterial cannulation will be performed via the radial or femoral artery) under local anaesthesia. The sheath will be inserted and a pre-procedure blood sample taken for Troponin T level. A coronary angiogram will be performed as per standard clinical practice prior to cannulating the coronary artery to be studied. The pressure studies will be performed sequentially, first with a pressure wire before using the iKOs™ microcatheter. Following withdrawal of the iKOs™ microcatheter. A pressure wire assessment is repeated after the microcatheter is withdrawn. The case will then proceed as clinically indicated. Post-procedure the participant will be managed according to standard clinical practice.', 'armGroupLabels': ['Intra coronary rapid-exchange iKOs microcatheter intervention']}]}, 'contactsLocationsModule': {'locations': [{'zip': 'EC1A 7BE', 'city': 'London', 'state': 'England', 'country': 'United Kingdom', 'facility': "St Bartholomew's Hospital", 'geoPoint': {'lat': 51.50853, 'lon': -0.12574}}], 'overallOfficials': [{'name': 'Anthony Mathur', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Queen Mary University of London'}]}, 'ipdSharingStatementModule': {'ipdSharing': 'NO'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Queen Mary University of London', 'class': 'OTHER'}, 'collaborators': [{'name': 'Echopoint Medical Ltd', 'class': 'UNKNOWN'}], 'responsibleParty': {'type': 'SPONSOR'}}}}