Viewing Study NCT02128412


Ignite Creation Date: 2025-12-26 @ 11:13 PM
Ignite Modification Date: 2026-02-25 @ 3:27 AM
Study NCT ID: NCT02128412
Status: UNKNOWN
Last Update Posted: 2016-10-17
First Post: 2014-04-28
Is Gene Therapy: True
Has Adverse Events: False

Brief Title: IVUS Controlled Stenting
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'RANDOMIZED', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'TREATMENT', 'interventionModel': 'PARALLEL'}, 'enrollmentInfo': {'type': 'ESTIMATED', 'count': 40}}, 'statusModule': {'overallStatus': 'UNKNOWN', 'lastKnownStatus': 'ACTIVE_NOT_RECRUITING', 'startDateStruct': {'date': '2014-02'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2016-10', 'completionDateStruct': {'date': '2016-11', 'type': 'ESTIMATED'}, 'lastUpdateSubmitDate': '2016-10-14', 'studyFirstSubmitDate': '2014-04-28', 'studyFirstSubmitQcDate': '2014-04-29', 'lastUpdatePostDateStruct': {'date': '2016-10-17', 'type': 'ESTIMATED'}, 'studyFirstPostDateStruct': {'date': '2014-05-01', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2016-10', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Number of stents which are optimally deployed as assessed against the MUSIC criteria', 'timeFrame': 'Immediately after stent is deployed until optimal deployment is achieved', 'description': 'The criteria for optimal stent expansion are:\n\n1\\. Complete apposition of the stent over its entire length against the vessel wall.\n\n2a. In stent minimal luminal area (MLA) \\>= 90% of the average reference luminal area or \\>=100% of lumen area of the reference segment with the lowest lumen area.\n\nIn stent lumen area of proximal stent entrance \\>= 90% of proximal lumen area. 2b. Where the instent luminal area is in excess of 9.0 mm2 , the following criteria apply: In stent MLA \\> 80% of the average reference lumen area or \\>=90% of lumen area of the reference segment with the lowest lumen area.\n\nIn stent lumen area of proximal stent entrance \\>= 90% of proximal lumen area. 3. Symmetric stent expansion defined by lumen diameter (LD)min / LD max \\>= 0.7\n\nA less rigorous criteria for stent expansion will also be assessed:\n\n1. In stent MLA \\> 80% of the average reference lumen area; \\&\n2. Complete apposition of the stent over its entire length against the vessel wall'}], 'secondaryOutcomes': [{'measure': 'Clinical endpoints including death, myocardial infarction, coronary artery bypass surgery, repeat percutaneous intervention, stent thrombosis, myonecrosis', 'timeFrame': '1-3 days following procedure and at 6 months'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'keywords': ['Patients scheduled to undergo coronary angioplasty and stenting because of symptoms related to a single de novo coronary artery stenoses'], 'conditions': ['Coronary Angioplasty and Stenting', 'Single de Novo Coronary Artery Stenoses']}, 'descriptionModule': {'briefSummary': 'Stent placement is now widely accepted to improve the results of angioplasty (an operation to widen the blood vessel) and decreasing the need for further surgery. Despite their worldwide acceptance, stent usage is still limited by renarrowing which occurs within the stent (restenosis) in some patients within the first six months. In addition there still exists a small risk of heart attacks soon after the stent is placed.\n\nThe purpose of this study is to test the safety and tolerability of trying to place the stents using a different strategy of using low pressure oversized balloon inflations as opposed to the usual high pressure balloon inflations. This may reduce injury to the artery and reduce the chance of renarrowing of the stent. In order to ensure this is a safe and effective way of performing the procedure the investigators intend to use an Intravascular ultrasound (IVUS) catheter to look from inside the artery at the stents. IVUS has proven to be the best way of ensuring optimal stent placement.\n\nPrimary hypothesis: Stents will be equally well expanded and apposed using a strategy of oversized stenting at normal inflation pressures ( \\< 10 atmospheres ) as compared to high pressure inflation (≥14 atmospheres) as guided by intravascular ultrasound imaging.\n\nSecondary Hypothesis: There will be no difference in acute clinical endpoints (death, myocardial infarction, urgent revascularisation or stent thrombosis) using a strategy of oversized stenting at normal inflation pressure as compared to high pressure inflation.\n\nTertiary Hypothesis: If the above is shown to be true the investigators would hope to expand the study in order to reveal a decrease in stent restenosis using a strategy of lower pressure balloon inflations. The investigators will assess the deployment characteristics of drug eluting versus bare metal stents'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'maximumAge': '85 Years', 'minimumAge': '18 Years', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Patients who are scheduled for a coronary angioplasty and stenting\n* Single de novo artery stenosis are eligible for this study\n* Target lesion needs to be less than 30mm long and located in a vessel more than 2.5 mm in diameter\n\nExclusion Criteria:\n\n* Contraindication to antiplatelet therapy;\n* Ostial lesion;\n* Excessive vessel tortuosity;\n* Lesion at a significant bifurcation (subbranch ≥ 2mm in diameter);\n* Suspected intracoronary thrombus.'}, 'identificationModule': {'nctId': 'NCT02128412', 'briefTitle': 'IVUS Controlled Stenting', 'organization': {'class': 'OTHER_GOV', 'fullName': 'Sydney South West Area Health Service'}, 'officialTitle': 'Expansion of Intracoronary Stents by Low Pressure Oversizing Versus High Pressure Inflation: A Randomised Intracoronary Ultrasound Controlled Study', 'orgStudyIdInfo': {'id': '2013/167'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'ACTIVE_COMPARATOR', 'label': 'Stent oversize group', 'description': 'Oversized stent deployed at low pressure:\n\nA stent premounted on a balloon with a nominal diameter halfway between the lumen diameter and the true vessel diameter (approximated by external elastic lamina) as assessed by IVUS. This will be based on the smallest of the vessel reference diameters proximal and distal to the lesion. In addition the vessel diameter must be greater than this diameter throughout the length of the lesion. This stent will be implanted at an inflation pressure of 10 atmospheres or less for at least 15 seconds and a second IVUS will be performed to assess the end point.', 'interventionNames': ['Device: Oversized stent deployed at low pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent)']}, {'type': 'ACTIVE_COMPARATOR', 'label': 'High pressure group', 'description': 'Stent deployed at high pressure:\n\nA stent premounted on a balloon with a nominal diameter approximately equal to the vessel segment lumen reference diameter as previously assessed by IVUS will be used. This stent will be implanted at an inflation pressure of 14 atmospheres or more for at least 15 seconds and a second IVUS will be performed to assess the end point', 'interventionNames': ['Device: Stent deployed at high pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent)']}], 'interventions': [{'name': 'Oversized stent deployed at low pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent)', 'type': 'DEVICE', 'description': 'Stent can include both bare metal stents and drug eluting stents. Depending on availabilities, different stent brands may be used.', 'armGroupLabels': ['Stent oversize group']}, {'name': 'Stent deployed at high pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent)', 'type': 'DEVICE', 'description': 'Stent can include both bare metal stents and drug eluting stents. Depending on availabilities, different stent brands may be used.', 'armGroupLabels': ['High pressure group']}]}, 'contactsLocationsModule': {'locations': [{'zip': '2170', 'city': 'Liverpool', 'state': 'New South Wales', 'country': 'Australia', 'facility': 'Department of Cardiology', 'geoPoint': {'lat': -33.91938, 'lon': 150.92588}}], 'overallOfficials': [{'name': 'Craig Juergens, Cardiologist', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'South West Sydney, Liverpool'}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Sydney South West Area Health Service', 'class': 'OTHER_GOV'}, 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'Research Medical Student', 'investigatorFullName': 'Esther Zhou', 'investigatorAffiliation': 'Sydney South West Area Health Service'}}}}