Viewing Study NCT04860895


Ignite Creation Date: 2025-12-24 @ 1:41 PM
Ignite Modification Date: 2025-12-31 @ 3:40 AM
Study NCT ID: NCT04860895
Status: UNKNOWN
Last Update Posted: 2021-05-06
First Post: 2021-04-25
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Detection of SARS-CoV-2 in Nasopharyngeal Swabs by Using Multi-Spectral Screening System
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D000086382', 'term': 'COVID-19'}], 'ancestors': [{'id': 'D011024', 'term': 'Pneumonia, Viral'}, {'id': 'D011014', 'term': 'Pneumonia'}, {'id': 'D012141', 'term': 'Respiratory Tract Infections'}, {'id': 'D007239', 'term': 'Infections'}, {'id': 'D014777', 'term': 'Virus Diseases'}, {'id': 'D018352', 'term': 'Coronavirus Infections'}, {'id': 'D003333', 'term': 'Coronaviridae Infections'}, {'id': 'D030341', 'term': 'Nidovirales Infections'}, {'id': 'D012327', 'term': 'RNA Virus Infections'}, {'id': 'D008171', 'term': 'Lung Diseases'}, {'id': 'D012140', 'term': 'Respiratory Tract Diseases'}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'DIAGNOSTIC', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ESTIMATED', 'count': 4400}}, 'statusModule': {'overallStatus': 'UNKNOWN', 'lastKnownStatus': 'RECRUITING', 'startDateStruct': {'date': '2021-02-11', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2021-05', 'completionDateStruct': {'date': '2021-05-15', 'type': 'ESTIMATED'}, 'lastUpdateSubmitDate': '2021-05-02', 'studyFirstSubmitDate': '2021-04-25', 'studyFirstSubmitQcDate': '2021-04-25', 'lastUpdatePostDateStruct': {'date': '2021-05-06', 'type': 'ACTUAL'}, 'studyFirstPostDateStruct': {'date': '2021-04-27', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2021-05-01', 'type': 'ESTIMATED'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': "Assessment of AI's Learning Performance:", 'timeFrame': '2 MONTHS', 'description': 'Compared PCR results with AP-23 results; PCR Accordance, PCR Accordance for Negative Samples, PCR Accordance for Positive Samples.'}, {'measure': "Evaluation of Artificial Intelligence's Test Performance)", 'timeFrame': '1 MONTH', 'description': 'As a result of comparison with the PCR and AP-23 results in nasopharyngeal swab samples; Sensitiviy, Specificity, Negative Prediction Value, Positive Prediction Value'}]}, 'oversightModule': {'oversightHasDmc': True, 'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': False}, 'conditionsModule': {'keywords': ['Artificial Intelligence, AI, SARS-COV2, Point of Care,'], 'conditions': ['Covid19']}, 'referencesModule': {'references': [{'pmid': '40419915', 'type': 'DERIVED', 'citation': 'Tayfur I, Bayramoglu B, Guven R, Avci A. Diagnostic accuracy of artificial intelligence-based multi-spectrum analysis for molecular fingerprint detection of SARS-CoV-2. Medicine (Baltimore). 2025 May 23;104(21):e41928. doi: 10.1097/MD.0000000000041928.'}]}, 'descriptionModule': {'briefSummary': "The aim of this research is to use the Multi-Spectral method to measure the biomolecular fingerprint of the virus directly instead of the virus's RNA (RT-PCR) or the body's immune response (antibody) measurement methods to diagnose the SARS-COV-2 virus, thereby determining whether COVID-19 can be diagnosed faster, cheaper and without requiring a medical laboratory environment.", 'detailedDescription': "The primary purpose of this study is to test whether artificial intelligence (AI) will identify existing SARS-COV-2 in nasopharyngeal swab samples using multi-spectral screening technology..\n\nMulti spectral screening testing device called AP-23 offers a non-invasive system for the diagnosis of SARS-COV-2 as a solution. This approach makes multi-spectral diagnostic methods suitable for use by any end user and allows the establishment of Internet of Things systems.\n\nCOVID-19 contagion, which began in the northern hemisphere, continues to affect human health and the world economy in tremendously. Early diagnosis of the disease and, accordingly, the breaking of the transmission chain through filiation studies is very important for public health until an effective and safe vaccine is found. PCR tests, which we currently use as the gold standard to prove the existence of the virus, have not been sufficient to prevent the pandemic for the following reasons;\n\n1. PCR tests should be performed in a hospital or clinical setting\n2. There is a need for a custom kit\n3. There is a need for trained individuals to perform the test\n4. Standardization is not ensured for the receipt of test sample\n5. With at least 30 minutes for receipt of the test results, it takes up to 3-day\n6. testing is expensive and is usually applied to people who have symptoms and thus asymptomatic carriers are missed.\n\nThe primary purpose of this study is to test whether SARS-COV-2 can be detected in nasopharyngeal swab samples using multi-spectral screening technology. Multi-spectral techniques are based on phenomena related to absorption, excitation and propagation of biomolecules. In short, by irradiating the sample with electromagnetic energy, some molecules absorb and re-emit less energetic radiation. This phenomenon is called radiation, and the radiated spectrum is a function of certain molecules that combine microorganisms / viruses.\n\nAt this point, FableCorp's AP-23 system uses data from a minimally invasive or non-invasive simple measurement based on multi-spectral screening technology to calculate the presence or concentration of the desired product in a biological liquid as the solution to be used.\n\nThe most unique approach of the FableCorp system, is to use the A.I. to detect the desired biochemical / cell / virus is to scan appropriate multi-spectral inputs. Data mining tools, where it simultaneously eliminates noise in raw data generated from various multi-spectral spectroscopy inputs, give very clear results. This approach makes multi-spectral technology suitable for use as point-of-care systems for any end user, and also leads to the realization of full automation (Internet of Things) systems.\n\nA.I. the base solution for Pointer signal detection / processing eliminates biochemical additives (kits) and specialized personnel.\n\nAI's evaluation of data takes place within 15-30 seconds. If the effectiveness of this application is proven in the diagnosis of SARS-COV-2, many more people will be able to be screened in a much faster time, much cheaper, and filiation will be applied to the necessary people much faster.\n\nStudy Design Stage 1: Nasopharyngeal samples taken from COVID-19 suspected individuals will be given to artificial intelligence to learn positive and negative cases, and the learning results will be calculated as the learning accuracy for negative and positive samples. (n=4000, 2000 positive and 2000 negative)\n\nStage 1, Output Parameters (Evaluation of Learning Performance of Artificial Intelligence):\n\nPCR results and AP-23 results obtained as a result of comparison; PCR Accordance, PCR Accordance for Negative Samples, PCR Accordance for Positive Samples.\n\nStage 2: Based on the Artificial Intelligence Learning accuracy rate second stage of the study will be initiated. At this stage, Nasopharyngeal swab samples will be tested by PCR, AP-23, and the results will be tested and be compared and the sensitivity of detection compared with results obtained by (n=400, 200 positive and 200 negative)\n\nStage 2, Output Parameters (Evaluation of Test Performance of Artificial Intelligence):\n\nNasopharyngeal swab obtained by comparison with PCR and AP-23 results in samples; Sensitivity, Specificity, Negative Prediction Value, Positive Prediction Value."}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['CHILD', 'ADULT', 'OLDER_ADULT'], 'maximumAge': '95 Years', 'minimumAge': '12 Years', 'healthyVolunteers': True, 'eligibilityCriteria': 'Inclusion Criteria:\n\nAll people who applied to hospitals with suspicion of COVID-19\n\nExclusion Criteria:\n\nPerson who cannot give nasopharyngeal samples'}, 'identificationModule': {'nctId': 'NCT04860895', 'briefTitle': 'Detection of SARS-CoV-2 in Nasopharyngeal Swabs by Using Multi-Spectral Screening System', 'organization': {'class': 'INDUSTRY', 'fullName': 'Fable Biyoteknoloji San ve Tic A.S'}, 'officialTitle': 'The Reliability of the Computer Aided Multi-Spectral Screening System In the Diagnosis of Covid-19', 'orgStudyIdInfo': {'id': 'SNCKTP_AP-23'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'OTHER', 'label': 'Nasopharyngeal swabs', 'description': 'Nasopharyngeal swabs samples of volunteers who is referred with suspicion of Covid19.', 'interventionNames': ['Diagnostic Test: AP-23']}], 'interventions': [{'name': 'AP-23', 'type': 'DIAGNOSTIC_TEST', 'description': 'AP-23 newly developed point of care system as a well-automated combination of multi-spectral technology and a distributed cloud computing A.I. system which has been developed to detect COVID-19.', 'armGroupLabels': ['Nasopharyngeal swabs']}]}, 'contactsLocationsModule': {'locations': [{'zip': '34785', 'city': 'Sancaktepe', 'state': 'Istanbul', 'status': 'RECRUITING', 'country': 'Turkey (Türkiye)', 'contacts': [{'name': 'İsmail Tayfur, MD', 'role': 'CONTACT'}], 'facility': 'Sancaktepe Şehit Prof.Dr. İlhan Varank Training and Research Hospital', 'geoPoint': {'lat': 41.00244, 'lon': 29.23187}}], 'centralContacts': [{'name': 'Deniz Unver, MSc.', 'role': 'CONTACT', 'email': 'deniz.unver@fablecorp.com', 'phone': '+905380246808'}, {'name': 'Emre Günerken', 'role': 'CONTACT', 'email': 'emre.gunerken@fablecorp.com', 'phone': '905360300713'}], 'overallOfficials': [{'name': 'İsmail Tayfur, MD', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Sehit Prof. Dr. Ilhan Varank Sancaktepe Training and Research Hospital'}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Fable Biyoteknoloji San ve Tic A.S', 'class': 'INDUSTRY'}, 'responsibleParty': {'type': 'SPONSOR'}}}}