Viewing Study NCT01714895


Ignite Creation Date: 2025-12-24 @ 1:39 PM
Ignite Modification Date: 2025-12-28 @ 9:30 PM
Study NCT ID: NCT01714895
Status: COMPLETED
Last Update Posted: 2012-10-26
First Post: 2012-10-24
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Effect of Different Plasma Insulin Levels on the Accuracy of Continuous Subcutaneous Glucose Monitoring
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D003922', 'term': 'Diabetes Mellitus, Type 1'}, {'id': 'D007003', 'term': 'Hypoglycemia'}], 'ancestors': [{'id': 'D003920', 'term': 'Diabetes Mellitus'}, {'id': 'D044882', 'term': 'Glucose Metabolism Disorders'}, {'id': 'D008659', 'term': 'Metabolic Diseases'}, {'id': 'D009750', 'term': 'Nutritional and Metabolic Diseases'}, {'id': 'D004700', 'term': 'Endocrine System Diseases'}, {'id': 'D001327', 'term': 'Autoimmune Diseases'}, {'id': 'D007154', 'term': 'Immune System Diseases'}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'RANDOMIZED', 'maskingInfo': {'masking': 'DOUBLE', 'whoMasked': ['PARTICIPANT', 'OUTCOMES_ASSESSOR']}, 'primaryPurpose': 'BASIC_SCIENCE', 'interventionModel': 'CROSSOVER'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 14}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2011-10'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2012-10', 'completionDateStruct': {'date': '2012-10', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2012-10-24', 'studyFirstSubmitDate': '2012-10-24', 'studyFirstSubmitQcDate': '2012-10-24', 'lastUpdatePostDateStruct': {'date': '2012-10-26', 'type': 'ESTIMATED'}, 'studyFirstPostDateStruct': {'date': '2012-10-26', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2012-09', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Normalized current signal from the CGM devices', 'timeFrame': '330 minutes', 'description': 'CGM devices are electrochemical sensors. Currently available sensors are placed in the subcutaneous tissue where they react with the glucose of the interstitial fluid giving a current signal (in nano Amperes), which is proportional to glucose concentrations. The current signal is then filtered and transformed into plasma glucose estimations through a calibration algorithm built into the CGM device.\n\nIn this study we will analyze the current signal from CGM obtained under two different experimental conditions:\n\n1. Eu-hypoglycemic clamp with High plasma insulin concentrations\n2. Eu-hypoglycemic clamp with relatively Low plasma insulin concentrations\n\nThis will allow for establishing the role, if any, of different plasma insulin concentrations on the accuracy of CGM to identify plasma glucose falls resulting in hypoglycaemia.\n\nSince CGM sensors can exhibit different sensitivities to glucose concentrations, the current signal will be normalized before statistical analysis'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'keywords': ['Interstitial glucose dynamics', 'Accuracy of continuous glucose monitoring under hypoglycemia', 'Glucose clamp'], 'conditions': ['Type 1 Diabetes', 'Continuous Glucose Monitoring', 'Hypoglycemia']}, 'referencesModule': {'references': [{'pmid': '29638161', 'type': 'DERIVED', 'citation': 'Moscardo V, Bondia J, Ampudia-Blasco FJ, Fanelli CG, Lucidi P, Rossetti P. Plasma Insulin Levels and Hypoglycemia Affect Subcutaneous Interstitial Glucose Concentration. Diabetes Technol Ther. 2018 Apr;20(4):263-273. doi: 10.1089/dia.2017.0219. Epub 2018 Mar 12.'}]}, 'descriptionModule': {'briefSummary': 'Achieving near-normoglycaemia has been established as the main objective for most patients with diabetes. However, it is well known that intensification of treatment is associated with an increase in the frequency of hypoglycemia, especially in the context of insulin therapy. The burden of hypoglycemia in terms of psychological implications, morbidity and even mortality, explains why it has been defined as the main limiting factor to achievement of good metabolic control.\n\nContinuous subcutaneous glucose monitoring (CGM) devices have been claimed to be useful in hypoglycemia detection/prevention, allowing theoretically for safer intensification of therapy in diabetic patients. However, accuracy of CGM devices, especially in the hypoglycemic range, raises some concerns. In fact, commercially available CGM devices estimate plasma glucose from measurements in the interstitial fluid and not in plasma. However, the relationship between plasma and interstitial glucose is not fully understood, especially under dynamic conditions, and this may explain the poor CGM performance during rapid changes in blood glucose and hypoglycemia.\n\nIn this project, the relationship between plasma and interstitial glucose will be evaluated under conditions of normal glucose concentrations and hypoglycemia. Experiments will be performed to assess the role, if any, of different plasma insulin concentrations on the accuracy of CGM.\n\nAll the information obtained may be relevant to the improvement of the ability of CGM devices to detect hypoglycemia and hypoglycemic risk.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT'], 'maximumAge': '60 Years', 'minimumAge': '18 Years', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Subjects with type 1 diabetes mellitus meeting all of the following criteria will be considered for admission to the study:\n\n * Aged between 18 and 60 years\n * Under CSII or MDI treatment for at least six months before Visit 1\n * Body mass index of between 18 and 30 kg/m2\n * HbA1c 6.0-8.5% at Visit 1\n * Normal laboratory values, ECG, and vital signs unless the investigator considered an abnormality to be clinically irrelevant\n * Women postmenopausal or using contraception judged by the investigator to be adequate (e.g., oral contraceptives, intra-uterine device or surgical treatment)\n\nExclusion Criteria:\n\n* Subjects meeting any of the following criteria will not be included in the study:\n\n * Pregnancy and lactation\n * History of hypersensitivity to the study medications or to drugs with similar chemical structures\n * Confirmed hypoglycaemia unawareness\n * Progressive fatal diseases\n * History of drug or alcohol abuse\n * History of positive HIV or hepatitis B or C test\n * Impaired hepatic function, as shown by, but not limited to, SGPT or SGOT of more than twice the upper limit of the normal range at visit 1\n * Impaired renal function, as shown by, but not limited to, serum creatinine \\> 1.5 mg/dL at visit 1\n * Clinically relevant microvascular, cardiovascular, hepatic, neurologic, endocrine or other major systemic diseases other than T1DM which could hinder implementation of the clinical study protocol or interpretation of the study results\n * Pre-planned surgery during the study\n * Blood donation of more than 500 ml during the past three months for men, or during the past six months for women\n * Mental condition rendering the subject unable to understand the nature, scope and possible consequences of the study\n * Subject unlikely to comply with clinical study protocol, e.g., uncooperative attitude, inability to return for follow-up visits, or poor likelihood of completing the study\n * Receipt of an experimental drug or use of an experimental device during the past 30 days.'}, 'identificationModule': {'nctId': 'NCT01714895', 'briefTitle': 'Effect of Different Plasma Insulin Levels on the Accuracy of Continuous Subcutaneous Glucose Monitoring', 'organization': {'class': 'OTHER', 'fullName': 'Fundación para la Investigación del Hospital Clínico de Valencia'}, 'officialTitle': 'New Strategies for Automated Glycaemic Control: the Issue of Continuous Glucose Monitoring Accuracy Under Hypoglycaemic Conditions', 'orgStudyIdInfo': {'id': 'FP7-PEOPLE-2009-IEF #252085-2'}, 'secondaryIdInfos': [{'id': 'Spanish Ministry of Science', 'type': 'OTHER_GRANT', 'domain': 'spanish Ministry of Science, DPI2010-20764-C02-01'}]}, 'armsInterventionsModule': {'armGroups': [{'type': 'OTHER', 'label': 'High plasma insulin-Low plasma insulin', 'description': "Seven out of the 14 subjects recruited in the study have been randomized to receive on the first study day a High insulin glucose clamp and on the second day a Low insulin glucose clamp (sequence 'AB')", 'interventionNames': ['Other: High insulin eu-hypoglycemic clamp', 'Other: Low insulin eu-hypoglycemic clamp']}, {'type': 'OTHER', 'label': 'Low plasma insulin-High plasma insulin', 'description': "Seven out of the 14 subjects recruited in the study have been randomized to receive on the first study day a Low insulin glucose clamp and on the second day a High insulin glucose clamp (sequence 'BA')", 'interventionNames': ['Other: High insulin eu-hypoglycemic clamp', 'Other: Low insulin eu-hypoglycemic clamp']}], 'interventions': [{'name': 'High insulin eu-hypoglycemic clamp', 'type': 'OTHER', 'description': "Primed intravenous insulin infusion at a rate of 1mU/kg/min is given during the whole study duration. Glucose is infused at a variable rate to maintain plasma glucose concentrations 'clamped' at pre-specified levels. Plasma glucose levels will be the same in both study arms.", 'armGroupLabels': ['High plasma insulin-Low plasma insulin', 'Low plasma insulin-High plasma insulin']}, {'name': 'Low insulin eu-hypoglycemic clamp', 'type': 'OTHER', 'description': "Primed intravenous insulin infusion at a rate of 0.3mU/kg/min is given during the whole study duration. Glucose is infused at a variable rate to maintain plasma glucose concentrations 'clamped' at pre-specified levels. Plasma glucose levels will be the same in both study arms.", 'armGroupLabels': ['High plasma insulin-Low plasma insulin', 'Low plasma insulin-High plasma insulin']}]}, 'contactsLocationsModule': {'locations': [{'zip': '46010', 'city': 'Valencia', 'country': 'Spain', 'facility': 'Servicio de Endocrinología y Nutrición, Hospital Clínico Universitario de Valencia', 'geoPoint': {'lat': 39.47391, 'lon': -0.37966}}], 'overallOfficials': [{'name': 'Francisco Javier Ampudia-Blasco, MD, PhD', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Hospital Clínico Universitario de Valencia - Fundación INCLIVA'}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Fundación para la Investigación del Hospital Clínico de Valencia', 'class': 'OTHER'}, 'collaborators': [{'name': 'Universitat Politècnica de València', 'class': 'OTHER'}], 'responsibleParty': {'type': 'SPONSOR'}}}}