Viewing Study NCT04892056


Ignite Creation Date: 2025-12-24 @ 11:32 PM
Ignite Modification Date: 2025-12-25 @ 9:20 PM
Study NCT ID: NCT04892056
Status: COMPLETED
Last Update Posted: 2021-05-19
First Post: 2021-04-27
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Evaluation of the Rate of Anterior Segment Retraction Using Two Types of Mechanics
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'documentSection': {'largeDocumentModule': {'largeDocs': [{'date': '2019-01-03', 'size': 473391, 'label': 'Study Protocol and Statistical Analysis Plan', 'hasIcf': False, 'hasSap': True, 'filename': 'Prot_SAP_000.pdf', 'typeAbbrev': 'Prot_SAP', 'uploadDate': '2021-05-13T12:17', 'hasProtocol': True}, {'date': '2019-01-03', 'size': 188670, 'label': 'Informed Consent Form', 'hasIcf': True, 'hasSap': False, 'filename': 'ICF_001.pdf', 'typeAbbrev': 'ICF', 'uploadDate': '2021-05-13T12:17', 'hasProtocol': False}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'RANDOMIZED', 'maskingInfo': {'masking': 'SINGLE', 'whoMasked': ['OUTCOMES_ASSESSOR'], 'maskingDescription': 'Blinding of the principal investigator was not possible due to the nature of the interventions. However, the outcome assessor was blinded to the interventions and all digital models were unidentified during outcome assessment.'}, 'primaryPurpose': 'OTHER', 'interventionModel': 'PARALLEL'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 30}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2019-02-01', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2021-05', 'completionDateStruct': {'date': '2020-12-15', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2021-05-13', 'studyFirstSubmitDate': '2021-04-27', 'studyFirstSubmitQcDate': '2021-05-13', 'lastUpdatePostDateStruct': {'date': '2021-05-19', 'type': 'ACTUAL'}, 'studyFirstPostDateStruct': {'date': '2021-05-19', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2020-06-10', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Rate of Anterior Segment Retraction', 'timeFrame': 'The start of anterior segment retraction up to complete space closure, an average of 6 months.', 'description': 'The rate of anterior segment retraction per month was measured on monthly digital models.'}], 'secondaryOutcomes': [{'measure': 'Anchorage Loss', 'timeFrame': 'The start of anterior segment retraction up to complete space closure, an average of 6 months.', 'description': 'Mesial movement of the first primary molar was evaluated on the digital models'}, {'measure': 'Pain experienced after each activation of the two mechanics', 'timeFrame': 'The start of anterior segment retraction up to complete space closure, an average of 6 months.', 'description': 'Patients were asked to complete Visual Analogue Scales of the degree of pain after every intervention. The scale values between 0 to 10, with 0 being no pain experienced by the patient and 10 being the highest level of pain experienced.'}]}, 'oversightModule': {'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': False}, 'conditionsModule': {'keywords': ['T loops', 'Friction', 'Frictionless', 'power chains', 'digital models', 'anterior segment retraction'], 'conditions': ['Bimaxillary Protrusion']}, 'descriptionModule': {'briefSummary': 'The rate of anterior segment retraction in bi-maxillary protrusion cases was evaluated comparing the friction and friction-less mechanics. since, there has been a lack of clear cut guidelines for clinicians for the optimum method for retraction, this randomized clinical trial was done.', 'detailedDescription': 'Thirty bi-maxillary protrusion female patients were randomly allocated into either intervention groups. In the Friction group, retraction was accomplished using elastomeric power chains extending from crimpable hooks distal to the lateral incisors, on 0.017x0.025-inch Stainless Steel wires, to the mini-screws . While in the friction-less group with retraction done using T- loop springs made of 0.017x0.025-inch titanium molybdenum wires. Retraction force was set to 160g per side in both intervention groups. Activation was done every four weeks. Rate of anterior segment retraction was evaluated via digital models.'}, 'eligibilityModule': {'sex': 'FEMALE', 'stdAges': ['CHILD', 'ADULT'], 'maximumAge': '25 Years', 'minimumAge': '13 Years', 'healthyVolunteers': True, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Female Subjects.\n* Age 13-25 y of age.\n* Skeletal Angle Class I malocclusion with Bimaxillary dentoalveolar protrusion in need of four 1st premolar extractions with maximum anchorage.\n* Fully erupted permanent dentition without crowding.\n* Good oral and general health.\n\nExclusion Criteria:\n\n* Systemic Diseases or syndromes or on anti-inflammatory medication.\n* Extracted or missing permanent teeth.\n* History of previous Orthodontic Treatment.\n* Parafunctional Habits.\n* Badly decayed teeth.'}, 'identificationModule': {'nctId': 'NCT04892056', 'briefTitle': 'Evaluation of the Rate of Anterior Segment Retraction Using Two Types of Mechanics', 'organization': {'class': 'OTHER', 'fullName': 'Future University in Egypt'}, 'officialTitle': 'Evaluation of the Rate of Anterior Segment Retraction Using Friction Versus Frictionless Mechanics: A Randomized Clinical Trial', 'orgStudyIdInfo': {'id': 'FUE.REC 9/10-2018'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Anterior Segment Retraction using Friction mechanics by elastomeric power chains', 'description': 'Elastomeric power chains extending from 8mm crimpable hooks, distal to the lateral incisors, on 0.017"x0.025" Stainless Steel WIres, to the mini-screws. The power chains delivered 160g of force per side.', 'interventionNames': ['Other: Friction Mechanics']}, {'type': 'EXPERIMENTAL', 'label': 'Anterior Segment Retraction using Frictionless mechanics by T-loops', 'description': 'T shaped closing loops were fabricated on 0.017"x0.025" Titanium- Molybdenum wires (TMA) were used to deliver 160g of force per side by 4mm distal activations.', 'interventionNames': ['Other: Frictionless Mechanics']}], 'interventions': [{'name': 'Friction Mechanics', 'type': 'OTHER', 'otherNames': ['sliding mechanics'], 'description': 'anterior segment retraction using elastomeric power chains', 'armGroupLabels': ['Anterior Segment Retraction using Friction mechanics by elastomeric power chains']}, {'name': 'Frictionless Mechanics', 'type': 'OTHER', 'otherNames': ['segmented mechanics'], 'description': 'anterior segment retraction using closing loops', 'armGroupLabels': ['Anterior Segment Retraction using Frictionless mechanics by T-loops']}]}, 'contactsLocationsModule': {'locations': [{'city': 'Cairo', 'country': 'Egypt', 'facility': 'Future Univeristy in Egypt', 'geoPoint': {'lat': 30.06263, 'lon': 31.24967}}], 'overallOfficials': [{'name': 'Yehia Mostafa, Chairman', 'role': 'STUDY_CHAIR', 'affiliation': 'Future Univeristy in Egypt'}]}, 'ipdSharingStatementModule': {'infoTypes': ['STUDY_PROTOCOL', 'SAP', 'ICF'], 'timeFrame': 'After Publication', 'ipdSharing': 'YES', 'description': 'All collected IPD shared.'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Future University in Egypt', 'class': 'OTHER'}, 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'Principal Investigator', 'investigatorFullName': 'Monica Guirguis Youssif Tawfik', 'investigatorAffiliation': 'Future University in Egypt'}}}}