Viewing Study NCT07131995


Ignite Creation Date: 2025-12-24 @ 1:33 PM
Ignite Modification Date: 2026-01-02 @ 1:24 PM
Study NCT ID: NCT07131995
Status: COMPLETED
Last Update Posted: 2025-08-27
First Post: 2025-07-15
Is Gene Therapy: True
Has Adverse Events: False

Brief Title: Formative Usability Testing Study of a Novel Medical Device for Peritoneal Dialysis (WEAKID)
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'protocolSection': {'designModule': {'studyType': 'OBSERVATIONAL', 'designInfo': {'timePerspective': 'CROSS_SECTIONAL', 'observationalModel': 'OTHER'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 14}, 'patientRegistry': False}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2021-11-01', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2025-08', 'completionDateStruct': {'date': '2022-12-01', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2025-08-20', 'studyFirstSubmitDate': '2025-07-15', 'studyFirstSubmitQcDate': '2025-08-17', 'lastUpdatePostDateStruct': {'date': '2025-08-27', 'type': 'ESTIMATED'}, 'studyFirstPostDateStruct': {'date': '2025-08-20', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2022-12-01', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Use errors', 'timeFrame': 'During the procedure (usability test)', 'description': 'The number and percentages of incorrect actions during task performance. Reported per participant and for the total group.'}], 'secondaryOutcomes': [{'measure': 'Completion rate', 'timeFrame': 'During the procedure (usability test)', 'description': 'The number and percentages of tasks successfully completed during task performance. Reported per participant and for the total group.'}, {'measure': 'Perceived usability', 'timeFrame': 'Immediately after the procedure (usability test)', 'description': "Participants' perceived usability of the device using the 10-item System Usability Scale (0-100 scale). Scores were reported per participant and for the total group."}]}, 'oversightModule': {'oversightHasDmc': False, 'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': False}, 'conditionsModule': {'conditions': ['Peritoneal Dialysis']}, 'descriptionModule': {'briefSummary': "This study aimed to formatively test the usability of the WEarable Artificial KIDney (WEAKID) for peritoneal dialysis (PD) in the device's intended user populations (i.e., nurses and patients).", 'detailedDescription': "End stage renal disease is a growing health problem worldwide, with a growing number of patients requiring a kidney transplantation. Recent years have seen the development of multiple novel devices for both hemodialysis and peritoneal dialysis (PD), one of these devices being the WEarable Artificial KIDney (WEAKID) for PD. WEAKID uses both sorbent technology and continuous flow PD to improve dialysis efficacy. Here, we present the results of a formative usability testing study of WEAKID among nurses and patients. We included 14 participants (n=6 nurses, n=8 patients) in three participating centres (Modena University Hospital, Italy; La Paz University Hospital Madrid, Spain; University Medical Center Utrecht, the Netherlands). Participants were asked to perform basic operational procedures with the device according to a usability task list. Their performance was observed and use errors were noted. Furthermore, participants were asked for feedback, both verbally and by means of completing the system usability scale (SUS), reflecting perceived usability on a scale from 0 (worst) to 100 (best). In total, 22 use errors occurred, 10 in nurses and 12 in patients. The mean SUS score was 70 (range 57.5 - 85) for nurses, and 71.9 (range 55 - 87.5) for patients. Despite the slightly above-average perceived usability of the device's current design stage, participants made a lot of suggestions for improvements, and indeed, usability must be improved to make the device ready for market introduction."}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '18 Years', 'samplingMethod': 'NON_PROBABILITY_SAMPLE', 'studyPopulation': 'Participants represented two populations of intended users of the device, namely nurses and patients. The sample sizes were set at 6 (nurses) and 8 (patients). Prior work on the sample sizes of formative usability testing has shown that these sample sizes suffice to identify the most important design issues.', 'healthyVolunteers': True, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Nurses: aged 18 years or older, \\>1 years of professional experience with PD.\n* Patients: aged 18 years or older, clinical diagnosis of ESRD, any treatment experience with PD, either current or in the past.\n\nExclusion Criteria:\n\n* Nurses: none.\n* Patients: severe physical and/or cognitive impairment, as judged by the researchers.'}, 'identificationModule': {'nctId': 'NCT07131995', 'acronym': 'WEAKID', 'briefTitle': 'Formative Usability Testing Study of a Novel Medical Device for Peritoneal Dialysis (WEAKID)', 'organization': {'class': 'OTHER', 'fullName': 'UMC Utrecht'}, 'officialTitle': 'Formative Usability Testing Study of a Novel Medical Device for Peritoneal Dialysis (WEAKID)', 'orgStudyIdInfo': {'id': '21/616'}}, 'armsInterventionsModule': {'armGroups': [{'label': 'Nurses', 'description': 'Nurses, aged 18 years or older, and having \\>1 years of professional experience with PD.'}, {'label': 'Patients', 'description': 'Patients, aged 18 years or older, having a clinical diagnosis of ESRD and any treatment experience with PD, either current or in the past.'}]}, 'contactsLocationsModule': {'locations': [{'zip': '3584CX', 'city': 'Utrecht', 'state': 'Utrecht', 'country': 'Netherlands', 'facility': 'University Medical Center Utrecht', 'geoPoint': {'lat': 52.09083, 'lon': 5.12222}}]}, 'ipdSharingStatementModule': {'ipdSharing': 'NO', 'description': 'Privacy-sensitive information'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'UMC Utrecht', 'class': 'OTHER'}, 'collaborators': [{'name': 'Hospital Universitario La Paz', 'class': 'OTHER'}, {'name': "Azienda Unita' Sanitaria Locale Di Modena", 'class': 'OTHER'}], 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'Principal Investigator', 'investigatorFullName': 'Karin G.F. Gerritsen', 'investigatorAffiliation': 'UMC Utrecht'}}}}