Raw JSON
{'hasResults': True, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24', 'submissionTracking': {'firstMcpInfo': {'postDateStruct': {'date': '2021-02-01', 'type': 'ACTUAL'}}}}, 'conditionBrowseModule': {'meshes': [{'id': 'D007022', 'term': 'Hypotension'}, {'id': 'D006973', 'term': 'Hypertension'}], 'ancestors': [{'id': 'D014652', 'term': 'Vascular Diseases'}, {'id': 'D002318', 'term': 'Cardiovascular Diseases'}]}}, 'resultsSection': {'moreInfoModule': {'pointOfContact': {'email': 'Greta.Piper@nyulangone.org', 'phone': '212-263-4778', 'title': 'Greta Piper, MD', 'organization': 'NYU Langone Health'}, 'certainAgreement': {'piSponsorEmployee': True}}, 'adverseEventsModule': {'timeFrame': 'during intervention for 30 minutes', 'eventGroups': [{'id': 'EG000', 'title': 'Patients in SICU', 'description': 'Patients in the SICU with an intra-arterial blood pressure monitor already in place will be considered as subjects.\n\nNon-invasive non-oscillometric blood pressure wristband device: The device is a band intended to be worn on the wrist for intermittent blood pressure measurements. The device applies no inflatable mechanics or moving parts. The wristband is watertight and can be worn as any type of bracelet.\n\nInvasive intra-arterial blood pressure monitors.: Because the subjects also have an intra-arterial blood pressure monitor in place, the subjects will serve as their own control', 'otherNumAtRisk': 8, 'deathsNumAtRisk': 8, 'otherNumAffected': 0, 'seriousNumAtRisk': 8, 'deathsNumAffected': 0, 'seriousNumAffected': 0}], 'frequencyThreshold': '0'}, 'outcomeMeasuresModule': {'outcomeMeasures': [{'type': 'PRIMARY', 'title': 'Average Error in Blood Pressure Readings', 'denoms': [{'units': 'Participants', 'counts': [{'value': '8', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Patients in SICU', 'description': 'Patients in the SICU with an intra-arterial blood pressure monitor already in place will be considered as subjects.\n\nNon-invasive non-oscillometric blood pressure wristband device: The device is a band intended to be worn on the wrist for intermittent blood pressure measurements. The device applies no inflatable mechanics or moving parts. The wristband is watertight and can be worn as any type of bracelet.\n\nInvasive intra-arterial blood pressure monitors.: Because the subjects also have an intra-arterial blood pressure monitor in place, the subjects will serve as their own control'}], 'classes': [{'title': 'Systolic', 'categories': [{'measurements': [{'value': '-1.5', 'spread': '6.3', 'groupId': 'OG000'}]}]}, {'title': 'Diastolic', 'categories': [{'measurements': [{'value': '3.2', 'spread': '6.0', 'groupId': 'OG000'}]}]}], 'paramType': 'MEAN', 'timeFrame': 'during intervention for 30 minutes', 'description': 'If the value obtained from the LiveMetric determination lied within the range of the reference BP, an error of 0 mm Hg (0kPa) was assigned to this determination. If the value obtained from the LiveMetric determination lies outside the range of the reference BP, the value of the determination from the adjacent limit of the range of the variation of BP was subtracted. That difference represents the error for this determination.\n\nThe arithmetic mean of the error is calculated and its experimental standard deviation from the errors of each recording for each BP value (Systolic \\& Diastolic) and determination for each patient.', 'unitOfMeasure': 'mmHg', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED'}]}, 'participantFlowModule': {'groups': [{'id': 'FG000', 'title': 'Patients in SICU', 'description': 'Patients in the SICU with an intra-arterial blood pressure monitor already in place will be considered as subjects.\n\nNon-invasive non-oscillometric blood pressure wristband device: The device is a band intended to be worn on the wrist for intermittent blood pressure measurements. The device applies no inflatable mechanics or moving parts. The wristband is watertight and can be worn as any type of bracelet.\n\nInvasive intra-arterial blood pressure monitors.: Because the subjects also have an intra-arterial blood pressure monitor in place, the subjects will serve as their own control'}], 'periods': [{'title': 'Overall Study', 'milestones': [{'type': 'STARTED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '8'}]}, {'type': 'COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '8'}]}, {'type': 'NOT COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '0'}]}]}]}, 'baselineCharacteristicsModule': {'denoms': [{'units': 'Participants', 'counts': [{'value': '8', 'groupId': 'BG000'}]}], 'groups': [{'id': 'BG000', 'title': 'Patients in SICU', 'description': 'Patients in the SICU with an intra-arterial blood pressure monitor already in place will be considered as subjects.\n\nNon-invasive non-oscillometric blood pressure wristband device: The device is a band intended to be worn on the wrist for intermittent blood pressure measurements. The device applies no inflatable mechanics or moving parts. The wristband is watertight and can be worn as any type of bracelet.\n\nInvasive intra-arterial blood pressure monitors.: Because the subjects also have an intra-arterial blood pressure monitor in place, the subjects will serve as their own control'}], 'measures': [{'title': 'Age, Continuous', 'classes': [{'categories': [{'measurements': [{'value': '61.6', 'spread': '16.4', 'groupId': 'BG000'}]}]}], 'paramType': 'MEAN', 'unitOfMeasure': 'years', 'dispersionType': 'STANDARD_DEVIATION'}, {'title': 'Sex: Female, Male', 'classes': [{'categories': [{'title': 'Female', 'measurements': [{'value': '5', 'groupId': 'BG000'}]}, {'title': 'Male', 'measurements': [{'value': '3', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Race (NIH/OMB)', 'classes': [{'categories': [{'title': 'American Indian or Alaska Native', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Asian', 'measurements': [{'value': '1', 'groupId': 'BG000'}]}, {'title': 'Native Hawaiian or Other Pacific Islander', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Black or African American', 'measurements': [{'value': '3', 'groupId': 'BG000'}]}, {'title': 'White', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'More than one race', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Unknown or Not Reported', 'measurements': [{'value': '4', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Region of Enrollment', 'classes': [{'title': 'United States', 'categories': [{'measurements': [{'value': '8', 'groupId': 'BG000'}]}]}], 'paramType': 'NUMBER', 'unitOfMeasure': 'participants'}]}}, 'documentSection': {'largeDocumentModule': {'largeDocs': [{'date': '2019-07-18', 'size': 399874, 'label': 'Study Protocol and Statistical Analysis Plan', 'hasIcf': False, 'hasSap': True, 'filename': 'Prot_SAP_000.pdf', 'typeAbbrev': 'Prot_SAP', 'uploadDate': '2021-01-11T10:21', 'hasProtocol': True}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'DIAGNOSTIC', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 8}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2019-04-01', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2021-01', 'completionDateStruct': {'date': '2019-09-10', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2021-01-29', 'studyFirstSubmitDate': '2018-08-09', 'resultsFirstSubmitDate': '2021-01-11', 'studyFirstSubmitQcDate': '2018-08-09', 'lastUpdatePostDateStruct': {'date': '2021-02-02', 'type': 'ACTUAL'}, 'resultsFirstSubmitQcDate': '2021-01-29', 'studyFirstPostDateStruct': {'date': '2018-08-14', 'type': 'ACTUAL'}, 'resultsFirstPostDateStruct': {'date': '2021-02-02', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2019-09-10', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Average Error in Blood Pressure Readings', 'timeFrame': 'during intervention for 30 minutes', 'description': 'If the value obtained from the LiveMetric determination lied within the range of the reference BP, an error of 0 mm Hg (0kPa) was assigned to this determination. If the value obtained from the LiveMetric determination lies outside the range of the reference BP, the value of the determination from the adjacent limit of the range of the variation of BP was subtracted. That difference represents the error for this determination.\n\nThe arithmetic mean of the error is calculated and its experimental standard deviation from the errors of each recording for each BP value (Systolic \\& Diastolic) and determination for each patient.'}]}, 'oversightModule': {'isUsExport': True, 'oversightHasDmc': False, 'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': True}, 'conditionsModule': {'conditions': ['Hypotension', 'Hypertension']}, 'descriptionModule': {'briefSummary': 'The primary objective of the present investigation is to determine the accuracy of a non-invasive non-oscillometric blood pressure wristband device when compared to invasive intra-arterial blood pressure monitors. In an intensive care unit patients who already have an intra-arterial blood pressure monitor in place, this wristband device will be applied and blood pressure readings compared for approximately 15 minutes. Blood pressure readings will be gathered and compared.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'maximumAge': '100 Years', 'minimumAge': '18 Years', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Patients admitted to the Surgical Intensive Care Unit who are already fitted with an invasive Arterial Line (A- Line) are eligible for the trial, and no volunteers candidates for an A Line are requested.\n\nExclusion Criteria:\n\n* Within the candidate group of individuals whose procedure in the hospital requires an A-Line, the wristband may not, for various reasons, produce a clean signal. This is immediately determined after wearing the band (and may be related to the size of the wrist of the subject, among other things). Such candidates will be excluded from admission to the study.\n* All data from a subject shall be excluded if the invasive reference systolic blood range is greater than 20 mmHg (2, 67 kPa) or if the invasive reference diastolic range is more than 12 mmHg (1, 6 kPa) in any single determination.'}, 'identificationModule': {'nctId': 'NCT03629535', 'briefTitle': 'Accuracy of Non-invasive Non-oscillometric Blood Pressure Wristband', 'organization': {'class': 'OTHER', 'fullName': 'NYU Langone Health'}, 'officialTitle': 'Accuracy of Non-invasive Non-oscillometric Blood Pressure Wristband', 'orgStudyIdInfo': {'id': '17-00884'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Patients in SICU', 'description': 'Patients in the SICU with an intra-arterial blood pressure monitor already in place will be considered as subjects.', 'interventionNames': ['Device: Non-invasive non-oscillometric blood pressure wristband device', 'Device: Invasive intra-arterial blood pressure monitors.']}], 'interventions': [{'name': 'Non-invasive non-oscillometric blood pressure wristband device', 'type': 'DEVICE', 'description': 'The device is a band intended to be worn on the wrist for intermittent blood pressure measurements. The device applies no inflatable mechanics or moving parts. The wristband is watertight and can be worn as any type of bracelet.', 'armGroupLabels': ['Patients in SICU']}, {'name': 'Invasive intra-arterial blood pressure monitors.', 'type': 'DEVICE', 'description': 'Because the subjects also have an intra-arterial blood pressure monitor in place, the subjects will serve as their own control', 'armGroupLabels': ['Patients in SICU']}]}, 'contactsLocationsModule': {'locations': [{'zip': '10016', 'city': 'New York', 'state': 'New York', 'country': 'United States', 'facility': 'New York University School of Medicine', 'geoPoint': {'lat': 40.71427, 'lon': -74.00597}}], 'overallOfficials': [{'name': 'Greta Piper', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'NYU Langone Health'}]}, 'ipdSharingStatementModule': {'infoTypes': ['STUDY_PROTOCOL', 'SAP'], 'timeFrame': 'Beginning 9 months and ending 36 months following article publication or as required by a condition of awards and agreements supporting the research.', 'ipdSharing': 'YES', 'description': 'Individual participant data that underlie the results reported in this article, after deidentification (text, tables, figures, and appendices).', 'accessCriteria': 'Data will be available upon reasonable request. Individual participant data that underlie the results reported in this article, after deidentification (text, tables, figures, and appendices).Individual participant data that underlie the results reported in this article, after deidentification (text, tables, figures, and appendices).'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'NYU Langone Health', 'class': 'OTHER'}, 'responsibleParty': {'type': 'SPONSOR'}}}}