Viewing Study NCT01621503


Ignite Creation Date: 2025-12-24 @ 7:15 PM
Ignite Modification Date: 2025-12-30 @ 12:58 AM
Study NCT ID: NCT01621503
Status: COMPLETED
Last Update Posted: 2013-06-28
First Post: 2012-06-14
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Prospective Comparative Clinical Study to Investigate the Use of the NON CONTACT TONO/PACHYMETER NT-530P
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'DIAGNOSTIC', 'interventionModel': 'PARALLEL'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 250}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2011-04'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2012-07', 'completionDateStruct': {'date': '2013-01', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2013-06-26', 'studyFirstSubmitDate': '2012-06-14', 'studyFirstSubmitQcDate': '2012-06-14', 'lastUpdatePostDateStruct': {'date': '2013-06-28', 'type': 'ESTIMATED'}, 'studyFirstPostDateStruct': {'date': '2012-06-18', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2013-01', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'central corneal thickness', 'timeFrame': 'one day'}, {'measure': 'intraocular pressure', 'timeFrame': 'one day'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'conditions': ['IOP Ranges(mmHg): 7 to 16, >16 to <23, and 23 or More']}, 'descriptionModule': {'briefSummary': 'The primary objective of this clinical study is to collect clinical data to support an FDA 510(k) submission for the Nidek Non Contact Tono/ Pachymeter NT-530P. The secondary objective is to evaluate any adverse events found during the clinical study.', 'detailedDescription': 'Following data analysis will be conducted for tonometer and pachymeter readings. One of eyes of one patient becomes an object of the analysis. Regarding the intraocular pressure, higher IOP readings of either right or left eye are used for analysis. Regarding CCT, the readings of either right or left eye are randomly assigned to analysis in the order of registration.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '20 Years', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n1. IOP Measurement 1. 20 years or older who voluntarily agree to participate in this study after receiving adequate explanation 2. Possible to participate in the study regardless of existence of glaucoma\n2. CCT Measurement 1. 20 years or older who voluntarily agree to participate in this study after receiving adequate explanation 2. Possible to participate in the study regardless of existence of glaucoma 3. Possible to participate in the study regardless of existence of corneal diseases (such as Keratoconus, post-LASIK, and corneal scars)\n\nExclusion Criteria:\n\n1. IOP Measurement 1. Those with only one functional eye 2. Those with one eye having poor or eccentric fixation 3. Those with corneal scarring or who have had corneal surgery such as laser surgery 4. Microphthalmus 5. Buphthalmos 6. Contact lens wearers 7. Dry eyes 8. Blepharospasm 9. Nystagmus 10. Keratoconus 11. Those who have been diagnosed as having corneal conjunctivitis or other infectious disease 12. Those with central corneal thickness greater than 600 μm or less than 500 μm 13. A subject judged to be ineligible for participating in the study by the physicians in charge\n2. CCT Measurement 1. Those with only one functional eye 2. Those with one eye having poor or eccentric fixation 3. Blepharospasm 4. Nystagmus 5. Those who have been diagnosed as having corneal conjunctivitis or other infectious disease 6. A subject judged to be ineligible for participating in the study by the physicians in charge'}, 'identificationModule': {'nctId': 'NCT01621503', 'briefTitle': 'Prospective Comparative Clinical Study to Investigate the Use of the NON CONTACT TONO/PACHYMETER NT-530P', 'organization': {'class': 'INDUSTRY', 'fullName': 'Nidek Co. LTD.'}, 'officialTitle': 'Prospective Comparative Clinical Study to Investigate the Use of the NON CONTACT TONO/PACHYMETER NT-530P', 'orgStudyIdInfo': {'id': 'NT530P-120210'}}, 'armsInterventionsModule': {'interventions': [{'name': 'NT-530P', 'type': 'DEVICE', 'description': 'intraocular pressure and central corneal thickness measurement'}]}, 'contactsLocationsModule': {'locations': [{'zip': '430-0903', 'city': 'Hamamatsu', 'state': 'Shizuoka', 'country': 'Japan', 'facility': 'Kaiya ophthalmological clinic', 'geoPoint': {'lat': 34.7, 'lon': 137.73333}}, {'city': 'Tokyo', 'country': 'Japan', 'facility': 'Ochanomizu Inoue ophthalmological clinic', 'geoPoint': {'lat': 35.6895, 'lon': 139.69171}}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Nidek Co. LTD.', 'class': 'INDUSTRY'}, 'responsibleParty': {'type': 'SPONSOR'}}}}