Raw JSON
{'hasResults': True, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'resultsSection': {'moreInfoModule': {'pointOfContact': {'email': 'research@pointdesigns.com', 'phone': '7206004753', 'title': 'Director of Clinical Research', 'organization': 'Point Designs'}, 'certainAgreement': {'piSponsorEmployee': True}}, 'adverseEventsModule': {'timeFrame': 'an average of 1 day', 'eventGroups': [{'id': 'EG000', 'title': 'Prosthesis', 'description': 'Patient is temporarily fit with Point Partial partial finger prosthetic system\n\nPoint Partial: The Point Partial partial finger prosthetic system consists of 1-4 ratcheting mechanical partial digits and mounting brackets', 'otherNumAtRisk': 5, 'deathsNumAtRisk': 5, 'otherNumAffected': 0, 'seriousNumAtRisk': 5, 'deathsNumAffected': 0, 'seriousNumAffected': 0}], 'frequencyThreshold': '0'}, 'outcomeMeasuresModule': {'outcomeMeasures': [{'type': 'PRIMARY', 'title': 'VAL-1: System Comfort Validation Test', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Prosthesis', 'description': 'Patient is temporarily fit with Point Partial partial finger prosthetic system\n\nPoint Partial: The Point Partial partial finger prosthetic system consists of 1-4 ratcheting mechanical partial digits and mounting brackets'}], 'classes': [{'categories': [{'measurements': [{'value': '100', 'groupId': 'OG000'}]}]}], 'paramType': 'NUMBER', 'timeFrame': 'Day 1 (8 hours)', 'description': "User wears Point Partial(s) for a full day (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall be comfortable for a full day's use. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.", 'unitOfMeasure': '% of participants who Passed test', 'reportingStatus': 'POSTED'}, {'type': 'PRIMARY', 'title': 'VAL-2: Unilateral Function Validation Test', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Prosthesis', 'description': 'Patient is temporarily fit with Point Partial partial finger prosthetic system\n\nPoint Partial: The Point Partial partial finger prosthetic system consists of 1-4 ratcheting mechanical partial digits and mounting brackets'}], 'classes': [{'categories': [{'measurements': [{'value': '100', 'groupId': 'OG000'}]}]}], 'paramType': 'NUMBER', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User flexes and extends the Point Partial(s) without using contralateral hand (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall allow the user to flex and extend finger without their second hand. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.', 'unitOfMeasure': '% of participants who Passed test', 'reportingStatus': 'POSTED'}, {'type': 'PRIMARY', 'title': 'VAL-3.1: System Robustness Validation Test With 25 lb Bag', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Prosthesis', 'description': 'Patient is temporarily fit with Point Partial partial finger prosthetic system\n\nPoint Partial: The Point Partial partial finger prosthetic system consists of 1-4 ratcheting mechanical partial digits and mounting brackets'}], 'classes': [{'categories': [{'measurements': [{'value': '100', 'groupId': 'OG000'}]}]}], 'paramType': 'NUMBER', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User lifts a 25 lb. bag with Point Partial(s) (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall be robust enough to operate in challenging environments. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.', 'unitOfMeasure': '% of participants who Passed test', 'reportingStatus': 'POSTED'}, {'type': 'PRIMARY', 'title': 'VAL-3.2: Robustness Validation Test With Hammer', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Prosthesis', 'description': 'Patient is temporarily fit with Point Partial partial finger prosthetic system\n\nPoint Partial: The Point Partial partial finger prosthetic system consists of 1-4 ratcheting mechanical partial digits and mounting brackets'}], 'classes': [{'categories': [{'measurements': [{'value': '100', 'groupId': 'OG000'}]}]}], 'paramType': 'NUMBER', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User grips a hammer with Point Partial(s) and drives a nail into a piece of wood (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall be robust enough to operate in challenging environments. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.', 'unitOfMeasure': '% of participants who Passed test', 'reportingStatus': 'POSTED'}, {'type': 'PRIMARY', 'title': 'VAL-4: Object Release Validation Test', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Prosthesis', 'description': 'Patient is temporarily fit with Point Partial partial finger prosthetic system\n\nPoint Partial: The Point Partial partial finger prosthetic system consists of 1-4 ratcheting mechanical partial digits and mounting brackets'}], 'classes': [{'categories': [{'measurements': [{'value': '100', 'groupId': 'OG000'}]}]}], 'paramType': 'NUMBER', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User releases Point Partial(s) while performing an active grasp by pressing the dorsal button (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall be releasable while performing active grasps. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.', 'unitOfMeasure': '% of participants who Passed test', 'reportingStatus': 'POSTED'}, {'type': 'PRIMARY', 'title': 'VAL-5: Position Function Validation Test', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Prosthesis', 'description': 'Patient is temporarily fit with Point Partial partial finger prosthetic system\n\nPoint Partial: The Point Partial partial finger prosthetic system consists of 1-4 ratcheting mechanical partial digits and mounting brackets'}], 'classes': [{'categories': [{'measurements': [{'value': '100', 'groupId': 'OG000'}]}]}], 'paramType': 'NUMBER', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User positions Point Partial(s) into each of the locking positions (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall have a smooth ratcheting mechanism. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.', 'unitOfMeasure': '% of participants who Passed test', 'reportingStatus': 'POSTED'}, {'type': 'PRIMARY', 'title': 'VAL-6: Extension Function Validation Test', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Prosthesis', 'description': 'Patient is temporarily fit with Point Partial partial finger prosthetic system\n\nPoint Partial: The Point Partial partial finger prosthetic system consists of 1-4 ratcheting mechanical partial digits and mounting brackets'}], 'classes': [{'categories': [{'measurements': [{'value': '100', 'groupId': 'OG000'}]}]}], 'paramType': 'NUMBER', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User activates spring-back mechanism by using (1) contralateral hand, (2) tabletop, and (3) side or thigh throughout day without failed extension (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall have a reliable auto spring-back mechanism. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.', 'unitOfMeasure': '% of participants who Passed test', 'reportingStatus': 'POSTED'}, {'type': 'PRIMARY', 'title': 'VAL-7: Grip Functions Validation Test', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Prosthesis', 'description': 'Patient is temporarily fit with Point Partial partial finger prosthetic system\n\nPoint Partial: The Point Partial partial finger prosthetic system consists of 1-4 ratcheting mechanical partial digits and mounting brackets'}], 'classes': [{'categories': [{'measurements': [{'value': '100', 'groupId': 'OG000'}]}]}], 'paramType': 'NUMBER', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User grips a 5 lb. cylindrical smooth object using Point Partial(s) for 10 seconds (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall have high grip surface friction. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.', 'unitOfMeasure': '% of participants who Passed test', 'reportingStatus': 'POSTED'}, {'type': 'PRIMARY', 'title': 'VAL-8: Fine Motor Function Validation Test', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Prosthesis', 'description': 'Patient is temporarily fit with Point Partial partial finger prosthetic system\n\nPoint Partial: The Point Partial partial finger prosthetic system consists of 1-4 ratcheting mechanical partial digits and mounting brackets'}], 'classes': [{'categories': [{'measurements': [{'value': '100', 'groupId': 'OG000'}]}]}], 'paramType': 'NUMBER', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User picks up 1 coin from a smooth tabletop (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall have a pronounced fingernail. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.', 'unitOfMeasure': '% of participants who Passed test', 'reportingStatus': 'POSTED'}, {'type': 'PRIMARY', 'title': 'VAL-9: Overall Function & Robustness Validation Test', 'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Prosthesis', 'description': 'Patient is temporarily fit with Point Partial partial finger prosthetic system\n\nPoint Partial: The Point Partial partial finger prosthetic system consists of 1-4 ratcheting mechanical partial digits and mounting brackets'}], 'classes': [{'categories': [{'measurements': [{'value': '100', 'groupId': 'OG000'}]}]}], 'paramType': 'NUMBER', 'timeFrame': 'Day 1 (8 hours)', 'description': 'User performs VAL-1 through VAL-8 (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall be robustly attached to mounting system. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.', 'unitOfMeasure': '% of participants who Passed test', 'reportingStatus': 'POSTED'}]}, 'participantFlowModule': {'groups': [{'id': 'FG000', 'title': 'Prosthesis', 'description': 'Patient is temporarily fit with Point Partial partial finger prosthetic system\n\nPoint Partial: The Point Partial partial finger prosthetic system consists of 1-4 ratcheting mechanical partial digits and mounting brackets'}], 'periods': [{'title': 'Overall Study', 'milestones': [{'type': 'STARTED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '5'}]}, {'type': 'COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '5'}]}, {'type': 'NOT COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '0'}]}]}]}, 'baselineCharacteristicsModule': {'denoms': [{'units': 'Participants', 'counts': [{'value': '5', 'groupId': 'BG000'}]}], 'groups': [{'id': 'BG000', 'title': 'Prosthesis', 'description': 'Patient is temporarily fit with Point Partial partial finger prosthetic system\n\nPoint Partial: The Point Partial partial finger prosthetic system consists of 1-4 ratcheting mechanical partial digits and mounting brackets'}], 'measures': [{'title': 'Age, Categorical', 'classes': [{'categories': [{'title': '<=18 years', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Between 18 and 65 years', 'measurements': [{'value': '5', 'groupId': 'BG000'}]}, {'title': '>=65 years', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Sex: Female, Male', 'classes': [{'categories': [{'title': 'Female', 'measurements': [{'value': '1', 'groupId': 'BG000'}]}, {'title': 'Male', 'measurements': [{'value': '4', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Ethnicity (NIH/OMB)', 'classes': [{'categories': [{'title': 'Hispanic or Latino', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Not Hispanic or Latino', 'measurements': [{'value': '2', 'groupId': 'BG000'}]}, {'title': 'Unknown or Not Reported', 'measurements': [{'value': '3', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Race (NIH/OMB)', 'classes': [{'categories': [{'title': 'American Indian or Alaska Native', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Asian', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Native Hawaiian or Other Pacific Islander', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Black or African American', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'White', 'measurements': [{'value': '2', 'groupId': 'BG000'}]}, {'title': 'More than one race', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Unknown or Not Reported', 'measurements': [{'value': '3', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}]}}, 'documentSection': {'largeDocumentModule': {'largeDocs': [{'date': '2019-03-15', 'size': 696920, 'label': 'Study Protocol', 'hasIcf': False, 'hasSap': False, 'filename': 'Prot_000.pdf', 'typeAbbrev': 'Prot', 'uploadDate': '2024-08-21T16:35', 'hasProtocol': True}, {'date': '2019-10-22', 'size': 110955, 'label': 'Statistical Analysis Plan', 'hasIcf': False, 'hasSap': True, 'filename': 'SAP_001.pdf', 'typeAbbrev': 'SAP', 'uploadDate': '2024-08-21T16:36', 'hasProtocol': False}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'DEVICE_FEASIBILITY', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 5}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2020-11-03', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2024-08', 'completionDateStruct': {'date': '2022-12-31', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2024-08-21', 'studyFirstSubmitDate': '2021-08-12', 'resultsFirstSubmitDate': '2024-08-21', 'studyFirstSubmitQcDate': '2021-08-12', 'lastUpdatePostDateStruct': {'date': '2024-11-08', 'type': 'ACTUAL'}, 'resultsFirstSubmitQcDate': '2024-08-21', 'studyFirstPostDateStruct': {'date': '2021-08-19', 'type': 'ACTUAL'}, 'resultsFirstPostDateStruct': {'date': '2024-11-08', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2022-12-31', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'VAL-1: System Comfort Validation Test', 'timeFrame': 'Day 1 (8 hours)', 'description': "User wears Point Partial(s) for a full day (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall be comfortable for a full day's use. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test."}, {'measure': 'VAL-2: Unilateral Function Validation Test', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User flexes and extends the Point Partial(s) without using contralateral hand (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall allow the user to flex and extend finger without their second hand. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.'}, {'measure': 'VAL-3.1: System Robustness Validation Test With 25 lb Bag', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User lifts a 25 lb. bag with Point Partial(s) (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall be robust enough to operate in challenging environments. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.'}, {'measure': 'VAL-3.2: Robustness Validation Test With Hammer', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User grips a hammer with Point Partial(s) and drives a nail into a piece of wood (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall be robust enough to operate in challenging environments. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.'}, {'measure': 'VAL-4: Object Release Validation Test', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User releases Point Partial(s) while performing an active grasp by pressing the dorsal button (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall be releasable while performing active grasps. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.'}, {'measure': 'VAL-5: Position Function Validation Test', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User positions Point Partial(s) into each of the locking positions (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall have a smooth ratcheting mechanism. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.'}, {'measure': 'VAL-6: Extension Function Validation Test', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User activates spring-back mechanism by using (1) contralateral hand, (2) tabletop, and (3) side or thigh throughout day without failed extension (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall have a reliable auto spring-back mechanism. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.'}, {'measure': 'VAL-7: Grip Functions Validation Test', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User grips a 5 lb. cylindrical smooth object using Point Partial(s) for 10 seconds (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall have high grip surface friction. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.'}, {'measure': 'VAL-8: Fine Motor Function Validation Test', 'timeFrame': 'Day 1 (10 minutes)', 'description': 'User picks up 1 coin from a smooth tabletop (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall have a pronounced fingernail. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.'}, {'measure': 'VAL-9: Overall Function & Robustness Validation Test', 'timeFrame': 'Day 1 (8 hours)', 'description': 'User performs VAL-1 through VAL-8 (Pass/Fail). This validation method was used to confirm the following user need of the Point Partial has been met: Point Partial shall be robustly attached to mounting system. A simple pass/fail result was recorded for each user need for each participant. An overall passing rate above 80% across all user needs and participants is considered a success. Each participant attended a single-day experimental session. A day-use prosthetic socket was fabricated and Point Partials were mounted to the socket. Then, each participant attempted the validation test.'}]}, 'oversightModule': {'isUsExport': False, 'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': True}, 'conditionsModule': {'conditions': ['Amputation; Traumatic, Hand']}, 'descriptionModule': {'briefSummary': 'The objective of the device feasibility study will be to validate the user needs of the Point Partial system. This study will be a single group intervention model where one group of 5 partial finger amputees will be asked to perform several tasks. Successful completion of a task results in a fulfilled user need. Failure to complete a task results in an unfulfilled user need.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '18 Years', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Partial finger amputees with partial absence of index and/or middle fingers and presence of thumb. Additional finger loss is acceptable if all other criterion are met.\n* Fluent in English\n* Individuals aged 18 or greater\n* Patients may present with either fused or mobile MCP joints.\n\nExclusion Criteria:\n\n* Significant cognitive deficits as determined upon clinical evaluation\n* Significant neurological deficits as determined upon clinical evaluation\n* Significant physical deficits of the residual limb impacting full participation in the study as determined upon clinical evaluation\n* Uncontrolled pain or phantom pain impacting full participation in the study as determined upon OT evaluation\n* Serious uncontrolled medical problems as judged by the project therapist.'}, 'identificationModule': {'nctId': 'NCT05012657', 'briefTitle': 'Validation of Point Partial User Needs With Partial Finger Amputees', 'organization': {'class': 'INDUSTRY', 'fullName': 'Point Designs'}, 'officialTitle': 'Validation of Point Partial User Needs With Partial Finger Amputees', 'orgStudyIdInfo': {'id': '299089'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Prosthesis', 'description': 'Patient is temporarily fit with Point Partial partial finger prosthetic system', 'interventionNames': ['Device: Point Partial']}], 'interventions': [{'name': 'Point Partial', 'type': 'DEVICE', 'description': 'The Point Partial partial finger prosthetic system consists of 1-4 ratcheting mechanical partial digits and mounting brackets', 'armGroupLabels': ['Prosthesis']}]}, 'contactsLocationsModule': {'locations': [{'zip': '80045', 'city': 'Aurora', 'state': 'Colorado', 'country': 'United States', 'facility': 'University of Colorado Denver | Anschutz Medical Campus', 'geoPoint': {'lat': 39.72943, 'lon': -104.83192}}, {'zip': '80026', 'city': 'Lafayette', 'state': 'Colorado', 'country': 'United States', 'facility': 'Point Designs', 'geoPoint': {'lat': 39.9936, 'lon': -105.08971}}]}, 'ipdSharingStatementModule': {'ipdSharing': 'NO'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Point Designs', 'class': 'INDUSTRY'}, 'collaborators': [{'name': 'University of Colorado, Denver', 'class': 'OTHER'}], 'responsibleParty': {'type': 'SPONSOR'}}}}