Viewing Study NCT02614768


Ignite Creation Date: 2025-12-24 @ 6:29 PM
Ignite Modification Date: 2026-03-09 @ 1:58 AM
Study NCT ID: NCT02614768
Status: COMPLETED
Last Update Posted: 2023-05-06
First Post: 2015-11-24
Is Gene Therapy: True
Has Adverse Events: True

Brief Title: Standardized Evaluation of Subcutaneous Glucose Monitoring Systems Under Routine Environmental Conditions
Sponsor:
Organization:

Raw JSON

{'hasResults': True, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D003922', 'term': 'Diabetes Mellitus, Type 1'}], 'ancestors': [{'id': 'D003920', 'term': 'Diabetes Mellitus'}, {'id': 'D044882', 'term': 'Glucose Metabolism Disorders'}, {'id': 'D008659', 'term': 'Metabolic Diseases'}, {'id': 'D009750', 'term': 'Nutritional and Metabolic Diseases'}, {'id': 'D004700', 'term': 'Endocrine System Diseases'}, {'id': 'D001327', 'term': 'Autoimmune Diseases'}, {'id': 'D007154', 'term': 'Immune System Diseases'}]}}, 'resultsSection': {'moreInfoModule': {'pointOfContact': {'email': 'julia.mader@medunigraz.at', 'phone': '0043316385', 'title': 'Mader, Julia, Assoz. Dr.med.univ.', 'phoneExt': '12383', 'organization': 'Medical University of Graz'}, 'certainAgreement': {'piSponsorEmployee': True}}, 'adverseEventsModule': {'eventGroups': [{'id': 'EG000', 'title': 'Glucose Sensor', 'description': 'Continuous subcutaneous glucose monitoring using four different CGM systems in parallel will be performed throughout the study. Insulin therapy will be performed by the subjects themselves, as under daily life conditions. For the hypoglycaemia experiment an increased insulin bolus will be administered with meals (180% of the subject\'s calculated mealtime dose).\n\nGlucose Sensor: The investigational intervention is CGM monitoring using four different CGM systems. Three of the four CGM devices which are used will be CGM systems which have received conformité européenne (CE) certification (Dexcom G4 Platinum, Medtronic MiniMed 640G system, Abbott FreeStyle Libre Flash). The SPIDIMAN sensor will be used for the first time in human subjects, does not yet have received CE certification and will be given an identifying label in addition to being labelled "for investigative use only".', 'otherNumAtRisk': 12, 'deathsNumAtRisk': 12, 'otherNumAffected': 3, 'seriousNumAtRisk': 12, 'deathsNumAffected': 0, 'seriousNumAffected': 0}], 'otherEvents': [{'term': 'Superficial excoriation', 'stats': [{'groupId': 'EG000', 'numAtRisk': 12, 'numEvents': 1, 'numAffected': 1}], 'organSystem': 'Skin and subcutaneous tissue disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Headache', 'stats': [{'groupId': 'EG000', 'numAtRisk': 12, 'numEvents': 1, 'numAffected': 1}], 'organSystem': 'Nervous system disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}, {'term': 'Vertigo', 'stats': [{'groupId': 'EG000', 'numAtRisk': 12, 'numEvents': 1, 'numAffected': 1}], 'organSystem': 'Ear and labyrinth disorders', 'assessmentType': 'SYSTEMATIC_ASSESSMENT'}], 'frequencyThreshold': '0'}, 'outcomeMeasuresModule': {'outcomeMeasures': [{'type': 'PRIMARY', 'title': 'Percentage of Test-to-Reference Measurement Pairs With an Absolute Relative Difference (ARD) ≤15%', 'denoms': [{'units': 'Participants', 'counts': [{'value': '12', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Glucose Sensor', 'description': 'Continuous subcutaneous glucose monitoring using four different CGM systems in parallel will be performed throughout the study. Insulin therapy will be performed by the subjects themselves, as under daily life conditions. For the hypoglycaemia experiment an increased insulin bolus will be administered with meals (180% of the subject\'s calculated mealtime dose).\n\nGlucose Sensor: The investigational intervention is CGM monitoring using four different CGM systems. Three of the four CGM devices which are used will be CGM systems which have received conformité européenne (CE) certification (Dexcom G4 Platinum, Medtronic MiniMed 640G system, Abbott FreeStyle Libre Flash). The SPIDIMAN sensor will be used for the first time in human subjects, does not yet have received CE certification and will be given an identifying label in addition to being labelled "for investigative use only".'}], 'classes': [{'title': 'Abbot', 'categories': [{'measurements': [{'value': '73.2', 'groupId': 'OG000'}]}]}, {'title': 'Dexcom', 'categories': [{'measurements': [{'value': '56.1', 'groupId': 'OG000'}]}]}, {'title': 'Medtronic', 'categories': [{'measurements': [{'value': '52.0', 'groupId': 'OG000'}]}]}], 'paramType': 'NUMBER', 'timeFrame': '36 hours', 'description': 'The primary outcome measure was overall sensor accuracy determined using ISO 15197:2013, which is percentage (%) of sensor values that are within ±0.8 mmol/L of the reference value at glucose concentrations \\<5.6 mmol/L and within ±15% at glucose concentrations ≥5.6 mmol/L. The sensor values were obtained using three different glucose monitoring systems, i.e. Abbott, Dexcom and Medtronic, in patients with T1D over a 12-hour period in standardized conditions. The reference values were obtained by analysis of venous plasma glucose samples.', 'unitOfMeasure': 'Percentage of sensor values', 'reportingStatus': 'POSTED'}]}, 'participantFlowModule': {'groups': [{'id': 'FG000', 'title': 'Glucose Sensor', 'description': 'Continuous subcutaneous glucose monitoring using four different CGM systems in parallel will be performed throughout the study. Insulin therapy will be performed by the subjects themselves, as under daily life conditions. For the hypoglycaemia experiment an increased insulin bolus will be administered with meals (180% of the subject\'s calculated mealtime dose).\n\nGlucose Sensor: The investigational intervention is CGM monitoring using four different CGM systems. Three of the four CGM devices which are used will be CGM systems which have received conformité européenne (CE) certification (Dexcom G4 Platinum, Medtronic MiniMed 640G system, Abbott FreeStyle Libre Flash). The SPIDIMAN sensor will be used for the first time in human subjects, does not yet have received CE certification and will be given an identifying label in addition to being labelled "for investigative use only".'}], 'periods': [{'title': 'Overall Study', 'milestones': [{'type': 'STARTED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '12'}]}, {'type': 'COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '12'}]}, {'type': 'NOT COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '0'}]}]}]}, 'baselineCharacteristicsModule': {'denoms': [{'units': 'Participants', 'counts': [{'value': '12', 'groupId': 'BG000'}]}], 'groups': [{'id': 'BG000', 'title': 'Glucose Sensor', 'description': 'Continuous subcutaneous glucose monitoring using four different CGM systems in parallel will be performed throughout the study. Insulin therapy will be performed by the subjects themselves, as under daily life conditions. For the hypoglycaemia experiment an increased insulin bolus will be administered with meals (180% of the subject\'s calculated mealtime dose).\n\nGlucose Sensor: The investigational intervention is CGM monitoring using four different CGM systems. Three of the four CGM devices which are used will be CGM systems which have received conformité européenne (CE) certification (Dexcom G4 Platinum, Medtronic MiniMed 640G system, Abbott FreeStyle Libre Flash). The SPIDIMAN sensor will be used for the first time in human subjects, does not yet have received CE certification and will be given an identifying label in addition to being labelled "for investigative use only".'}], 'measures': [{'title': 'Age, Categorical', 'classes': [{'categories': [{'title': '<=18 years', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Between 18 and 65 years', 'measurements': [{'value': '12', 'groupId': 'BG000'}]}, {'title': '>=65 years', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Sex: Female, Male', 'classes': [{'categories': [{'title': 'Female', 'measurements': [{'value': '5', 'groupId': 'BG000'}]}, {'title': 'Male', 'measurements': [{'value': '7', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Ethnicity (NIH/OMB)', 'classes': [{'categories': [{'title': 'Hispanic or Latino', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Not Hispanic or Latino', 'measurements': [{'value': '12', 'groupId': 'BG000'}]}, {'title': 'Unknown or Not Reported', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Region of Enrollment', 'classes': [{'title': 'Europe', 'categories': [{'measurements': [{'value': '12', 'groupId': 'BG000'}]}]}], 'paramType': 'NUMBER', 'unitOfMeasure': 'participants'}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'BASIC_SCIENCE', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 12}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2015-07', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2023-05', 'completionDateStruct': {'date': '2015-09', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2023-05-02', 'studyFirstSubmitDate': '2015-11-24', 'resultsFirstSubmitDate': '2022-12-05', 'studyFirstSubmitQcDate': '2015-11-24', 'lastUpdatePostDateStruct': {'date': '2023-05-06', 'type': 'ACTUAL'}, 'resultsFirstSubmitQcDate': '2023-05-02', 'studyFirstPostDateStruct': {'date': '2015-11-25', 'type': 'ESTIMATED'}, 'resultsFirstPostDateStruct': {'date': '2023-05-06', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2015-08', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Percentage of Test-to-Reference Measurement Pairs With an Absolute Relative Difference (ARD) ≤15%', 'timeFrame': '36 hours', 'description': 'The primary outcome measure was overall sensor accuracy determined using ISO 15197:2013, which is percentage (%) of sensor values that are within ±0.8 mmol/L of the reference value at glucose concentrations \\<5.6 mmol/L and within ±15% at glucose concentrations ≥5.6 mmol/L. The sensor values were obtained using three different glucose monitoring systems, i.e. Abbott, Dexcom and Medtronic, in patients with T1D over a 12-hour period in standardized conditions. The reference values were obtained by analysis of venous plasma glucose samples.'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'keywords': ['Glucose Monitoring System'], 'conditions': ['Diabetes Mellitus, Type 1']}, 'descriptionModule': {'briefSummary': 'The purpose of this study is to assess accuracy and reliability of the SPIDIMAN continuous glucose monitoring (CGM) sensor system with regard to values as measured by Super GL and compare these results with similar evaluations of the Medtronic MiniMed 640G system, the Abbott FreeStyle Libre Flash Sensor and the DexCom G4 Platinum Sensor in patients with type 1 Diabetes.', 'detailedDescription': 'The study is a single-center open-label study in patients with type 1 diabetes treated with continuous subcutaneous insulin infusion (CSII) or multiple daily injections (MDI) therapy. The study will include a total of 12 subjects.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '18 Years', 'healthyVolunteers': False, 'eligibilityCriteria': "Inclusion Criteria:\n\n* Informed consent obtained after being advised of the nature of the study\n* Male or female aged ≥18 years\n* Type 1 diabetes for at least 6 months according to the World Health Organization (WHO) definition\n* Treatment with multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII) for at least 3 months\n* Body Mass Index (BMI) \\< 35 kg/m²\n* Willing and able to wear 5 CGM devices for the duration of the study and undergo all study procedures.\n* HbA1c ≤ 86 mmol/mol\n\nExclusion Criteria:\n\n* Any disease or condition which the investigator or treating physician feels would interfere with the trial or the safety of the subject\n* Female of childbearing potential who is pregnant, breast-feeding or intend to become pregnant or is not using adequate contraceptive methods\n* Any mental condition rendering the subject incapable of giving his consent\n* Subject is using a medication that significantly impacts glucose metabolism (oral steroids) except if stable for at least the last three months and expected to remain stable for the study duration\n* Subject may not use acetaminophen (paracetamol) while participating in the study\n* Has severe medical or psychological condition(s) or chronic conditions/infections that in the opinion of the Investigator would compromise the subject's safety or successful participation in the study.\n* Subject is actively enrolled in another clinical trial\n* Known adrenal gland problem, pancreatic tumour, or insulinoma\n* Inability of the subject to comply with all study procedures\n* Inability of the subject to understand the patient information.\n* Subject donated blood in the last 3 months"}, 'identificationModule': {'nctId': 'NCT02614768', 'briefTitle': 'Standardized Evaluation of Subcutaneous Glucose Monitoring Systems Under Routine Environmental Conditions', 'organization': {'class': 'OTHER', 'fullName': 'Medical University of Graz'}, 'officialTitle': 'Standardized Evaluation of Subcutaneous Glucose Monitoring Systems Under Routine Environmental Conditions', 'orgStudyIdInfo': {'id': 'SPIDIMAN_01'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Glucose Sensor', 'description': "Continuous subcutaneous glucose monitoring using four different CGM systems in parallel will be performed throughout the study. Insulin therapy will be performed by the subjects themselves, as under daily life conditions. For the hypoglycaemia experiment an increased insulin bolus will be administered with meals (180% of the subject's calculated mealtime dose).", 'interventionNames': ['Device: Glucose Sensor']}], 'interventions': [{'name': 'Glucose Sensor', 'type': 'DEVICE', 'description': 'The investigational intervention is CGM monitoring using four different CGM systems. Three of the four CGM devices which are used will be CGM systems which have received conformité européenne (CE) certification (Dexcom G4 Platinum, Medtronic MiniMed 640G system, Abbott FreeStyle Libre Flash). The SPIDIMAN sensor will be used for the first time in human subjects, does not yet have received CE certification and will be given an identifying label in addition to being labelled "for investigative use only".', 'armGroupLabels': ['Glucose Sensor']}]}, 'contactsLocationsModule': {'overallOfficials': [{'name': 'Julia Mader, Prof. Dr.', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Medical University of Graz'}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Medical University of Graz', 'class': 'OTHER'}, 'responsibleParty': {'type': 'SPONSOR'}}}}