Viewing Study NCT04816266


Ignite Creation Date: 2025-12-24 @ 4:34 PM
Ignite Modification Date: 2025-12-28 @ 8:18 AM
Study NCT ID: NCT04816266
Status: UNKNOWN
Last Update Posted: 2021-03-25
First Post: 2021-03-23
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Comparative Study in Measuring Anterior Chamber Depth
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D012030', 'term': 'Refractive Errors'}], 'ancestors': [{'id': 'D005128', 'term': 'Eye Diseases'}]}}, 'protocolSection': {'designModule': {'studyType': 'OBSERVATIONAL', 'designInfo': {'timePerspective': 'CROSS_SECTIONAL', 'observationalModel': 'CASE_ONLY'}, 'enrollmentInfo': {'type': 'ESTIMATED', 'count': 50}, 'patientRegistry': False}, 'statusModule': {'overallStatus': 'UNKNOWN', 'lastKnownStatus': 'NOT_YET_RECRUITING', 'startDateStruct': {'date': '2021-04-01', 'type': 'ESTIMATED'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2021-03', 'completionDateStruct': {'date': '2023-04-01', 'type': 'ESTIMATED'}, 'lastUpdateSubmitDate': '2021-03-23', 'studyFirstSubmitDate': '2021-03-23', 'studyFirstSubmitQcDate': '2021-03-23', 'lastUpdatePostDateStruct': {'date': '2021-03-25', 'type': 'ACTUAL'}, 'studyFirstPostDateStruct': {'date': '2021-03-25', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2022-04-01', 'type': 'ESTIMATED'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Comparison between values of anterior chamber depth obtained by different devices', 'timeFrame': 'One year', 'description': 'Measuring Anterior chamber depth by Pentacam and iol master in eyes with different refractive errors'}]}, 'oversightModule': {'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': False}, 'conditionsModule': {'conditions': ['Error, Refractive']}, 'descriptionModule': {'briefSummary': 'Measuring parameters of anterior segment of the eye accurately is important for diagnosing variety of diseases and for cataract surgeries, glaucoma, refractive surgeries and post-operative follow-up. One of the anterior segment parameters is the anterior chamber depth.\n\nThe anterior chamber depth (ACD) measurement provides valuable information in different fields in ophthalmology. Firstly, it is important for the new theoretical biometric formulas used to calculate the power of intraocular lenses (IOLs) .Secondly, phakic IOL implantation requires precise ACD measurement for both surgical planning and IOL power calculation. Thirdly, the ACD is also implicated as a screening risk factor for glaucoma. Additionally, precise ACD measurement is thought to be important to the accurate determination of the optic zone ablation diameter for keratorefractive surgery, as well as for the analysis of postoperative ACD changes.\n\nDifferent technologies are used in measurement of the anterior chamber depth Such as pentacam and iol maste', 'detailedDescription': 'IOL master :\n\nOptical biometry by the IOL Master was introduced in the United Kingdom in 1999.Its technology is based on laser interfer-ometry with partial coherent light, termed as Partial Coherence Interferometry (PCI).The device uses the principle of PCI to measure the axial length of the eye.While uses a slit-beam photo-graphic technique for ACD measurements For keratometry measurement, six light spots are projected hexagonally on the cornea .The device records the reflection of these images measuring the separation of the opposite pairs of light spots and calculating the corneal radii and toroidal surface curvature. The mean of the taken measurements is considered the corneal power . The displayed K1 and K2 represent the average keratometry values at two major perpendicular meridians .For ACD measurement, the IOL Master directs a slit beam of light 0.7mm wide through the anterior segment at an angle of 38ยบ to the visual axis.The internal software measures the distance between anterior pole of the cornea and the anterior surface of the lens to calculate the ACD . The device takes five ACD measurements in rapid succession; the mean of these readings are taken as the ACD value . For WTW measurement, a digital grey-scale photograph of the anterior surface of the eye is taken after focusing on the iris. The limbus is then detected automatically and the WTW distance is measured\n\nPentacam :\n\nThe Pentacam obtains images of the anterior segment by a rotating Scheimpflug blue Light Emitting Diode (LED) with a wavelength of 475nm. It acquires 50 images in a duration of approximately two seconds. It extracts about 2,760 true elevation points from the obtained images which in turn generates 1 38,000 true elevation points for the both front and back corneal surfacesand from limbus to limbus, including the central part of the cornea . There for, it calculates k-readings of the cornea. The Pentacam HR calculates ACD from the corneal endothelial layer along a line from the apex of the cornea to the anterior surface of the lens . Horizontal WTW was measured by manual placement of callipers on the Scheimpflug image of the horizontal plane of the examined eye; callipers are placed on the corneo-scleral junction then a line is automat-ically drawn between the two points . The length of this line represents the WTW value'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT'], 'maximumAge': '40 Years', 'minimumAge': '18 Years', 'samplingMethod': 'NON_PROBABILITY_SAMPLE', 'studyPopulation': 'People between eighteen and forty years seeking for refractive surgery', 'eligibilityCriteria': 'Inclusion Criteria:\n\n* presenting for glasses\n* asking for refractive surgery\n\nExclusion Criteria:\n\n* severe corneal scarring or opacity\n* patients with corneal dystrophy\n* patients with keratoconus\n* patients with previous ocular surgery\n* patients with ocular trauma\n* patients with uveitis'}, 'identificationModule': {'nctId': 'NCT04816266', 'briefTitle': 'Comparative Study in Measuring Anterior Chamber Depth', 'organization': {'class': 'OTHER', 'fullName': 'Assiut University'}, 'officialTitle': 'Comparative Study Between Pentacam and IOL Master in Measuring Anterior Chamber Depth', 'orgStudyIdInfo': {'id': 'Anterior chamber depth'}}, 'armsInterventionsModule': {'armGroups': [{'label': 'Myopic patients', 'interventionNames': ['Device: Iol master', 'Device: Pentacam']}, {'label': 'Hypermetropic patients', 'interventionNames': ['Device: Iol master', 'Device: Pentacam']}, {'label': 'Emmetropic people', 'interventionNames': ['Device: Iol master', 'Device: Pentacam']}], 'interventions': [{'name': 'Iol master', 'type': 'DEVICE', 'description': 'Iol master measures the distance between anterior pole of the cornea and the anterior surface of the lens to calculate the anterior chamber depth', 'armGroupLabels': ['Emmetropic people', 'Hypermetropic patients', 'Myopic patients']}, {'name': 'Pentacam', 'type': 'DEVICE', 'description': 'The Pentacam HR calculates Anterior chamber depth from the corneal endothelial layer along a line from the apex of the cornea to the anterior surface of the lens', 'armGroupLabels': ['Emmetropic people', 'Hypermetropic patients', 'Myopic patients']}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Assiut University', 'class': 'OTHER'}, 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'Principal investigator', 'investigatorFullName': 'Engy Adel Fayez Demian', 'investigatorAffiliation': 'Assiut University'}}}}