Viewing Study NCT00599066


Ignite Creation Date: 2025-12-24 @ 4:04 PM
Ignite Modification Date: 2026-01-04 @ 9:01 AM
Study NCT ID: NCT00599066
Status: COMPLETED
Last Update Posted: 2017-04-14
First Post: 2007-12-20
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Intraoperative M-Entropy Measurements
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'protocolSection': {'designModule': {'studyType': 'OBSERVATIONAL', 'designInfo': {'timePerspective': 'PROSPECTIVE', 'observationalModel': 'CASE_ONLY'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 24}, 'patientRegistry': False}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2007-09'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2017-04', 'completionDateStruct': {'date': '2009-04', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2017-04-12', 'studyFirstSubmitDate': '2007-12-20', 'studyFirstSubmitQcDate': '2008-01-22', 'lastUpdatePostDateStruct': {'date': '2017-04-14', 'type': 'ACTUAL'}, 'studyFirstPostDateStruct': {'date': '2008-01-23', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2008-06', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'The investigators hypothesize that simultaneous M-Entropy measurements from the left and right side of the forehead of a person do not differ during general anesthesia.', 'timeFrame': '1 year'}]}, 'oversightModule': {'oversightHasDmc': True}, 'conditionsModule': {'keywords': ['M-Entropy'], 'conditions': ['General Anesthesia']}, 'referencesModule': {'references': [{'pmid': '16436841', 'type': 'BACKGROUND', 'citation': 'Niedhart DJ, Kaiser HA, Jacobsohn E, Hantler CB, Evers AS, Avidan MS. Intrapatient reproducibility of the BISxp monitor. Anesthesiology. 2006 Feb;104(2):242-8. doi: 10.1097/00000542-200602000-00007.'}, {'pmid': '14742389', 'type': 'BACKGROUND', 'citation': 'Ozcan MS, Gravenstein D. The presence of working memory without explicit recall in a critically ill patient. Anesth Analg. 2004 Feb;98(2):469-470. doi: 10.1213/01.ANE.0000096184.32247.D0.'}]}, 'descriptionModule': {'briefSummary': 'The purpose of this study is to learn more about an Entropy monitor that the anesthesiologist will be using.', 'detailedDescription': 'Depth of anesthesia monitors are increasingly used in clinical anesthesia practice. Bispectral Index (BIS) and M-Entropy are examples to these devices, both of which are available at our institution. Both BIS and M-Entropy use a unilateral, single channel of EEG to derive a number indicating the anesthetic depth. These devices have similar disposable skin probes that can be applied on either side of the forehead. Since the depth of anesthesia for an individual is the same over the whole brain cortex at a given point in time, BIS numbers obtained over the left and right side of the forehead should agree. The same should be true for M-Entropy as well.\n\nA recent study, however, showed that two separate BIS probes, applied over the left and right forehead of the same patient at the same time, can give significantly different numbers. This has not been studied for M-Entropy. BIS and M-Entropy use different mathematical algorithms that process the raw EEG signal to compute a numeric value. Therefore, it is possible that M-Entropy may show different results in a similar study setup.\n\nThe aim is to investigate the same-patient reproducibility of M-Entropy by monitoring and recording Entropy variables over both the left and the right side of the forehead of patients under general anesthesia.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'maximumAge': '90 Years', 'minimumAge': '18 Years', 'samplingMethod': 'NON_PROBABILITY_SAMPLE', 'studyPopulation': 'Patients that are scheduled to have surgery under general anesthesia for which an intraoperative M-Entropy monitoring is planned. Suitable candidates will be identified by speaking to the attending anesthesiologists working at OU Presbyterian hospital.', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Patients scheduled to have surgery under general anesthesia, with a minimum of 60 minutes expected duration.\n\nExclusion Criteria:\n\n* Non-English speaker\n* Patients younger than 18 years of age'}, 'identificationModule': {'nctId': 'NCT00599066', 'briefTitle': 'Intraoperative M-Entropy Measurements', 'organization': {'class': 'OTHER', 'fullName': 'University of Oklahoma'}, 'officialTitle': 'Same-patient Reproducibility of Intraoperative M-Entropy Measurements', 'orgStudyIdInfo': {'id': 'IRB No: 13577'}}, 'armsInterventionsModule': {'armGroups': [{'label': 'Study cases', 'description': 'Application of a second M-Entropy probe on the forehead of the patient; at the end the patient will have 2 probes on the forehead, one in the right and one in the left.', 'interventionNames': ['Device: study cases']}], 'interventions': [{'name': 'study cases', 'type': 'DEVICE', 'otherNames': ['M-entropy module (Datex-Ohmeda S/5 EntropyTM Module)'], 'description': 'Application of a second M-Entropy probe on the forehead of the patient, which will happen in the OR along with the application of other monitors immediately before induction of general anesthesia.', 'armGroupLabels': ['Study cases']}]}, 'contactsLocationsModule': {'locations': [{'zip': '73104', 'city': 'Oklahoma City', 'state': 'Oklahoma', 'country': 'United States', 'facility': 'OU MEDICAL CENTER, Presbyterian Tower, OR', 'geoPoint': {'lat': 35.46756, 'lon': -97.51643}}], 'overallOfficials': [{'name': 'Mehemet Ozcan, MD', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'The University of Oklahoma Health Sciences Center, Department of Anesthesiology'}]}, 'ipdSharingStatementModule': {'ipdSharing': 'NO'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'University of Oklahoma', 'class': 'OTHER'}, 'responsibleParty': {'type': 'SPONSOR'}}}}