Raw JSON
{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'protocolSection': {'designModule': {'studyType': 'OBSERVATIONAL', 'designInfo': {'timePerspective': 'PROSPECTIVE'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 26}, 'patientRegistry': False}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2012-07'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2013-12', 'lastUpdateSubmitDate': '2013-12-07', 'studyFirstSubmitDate': '2013-12-04', 'studyFirstSubmitQcDate': '2013-12-07', 'lastUpdatePostDateStruct': {'date': '2013-12-11', 'type': 'ESTIMATED'}, 'studyFirstPostDateStruct': {'date': '2013-12-11', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2013-04', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Comparison between arterial line and non-invasive device for blood pressure and difference in pulse pressure measurement', 'timeFrame': 'intraoperatively', 'description': 'Systolic, diastolic, mean blood pressure and difference in pulse pressure are measured intraoperatively with a non-invasive device and the reference technique. The values are compared using Bland-Altmann Analysis.'}]}, 'conditionsModule': {'conditions': ['Blood Pressure']}, 'referencesModule': {'references': [{'pmid': '19602972', 'type': 'BACKGROUND', 'citation': 'Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009 Sep;37(9):2642-7. doi: 10.1097/CCM.0b013e3181a590da.'}, {'pmid': '19448207', 'type': 'BACKGROUND', 'citation': 'Pestel G, Fukui K, Hartwich V, Schumacher PM, Vogt A, Hiltebrand LB, Kurz A, Fujita Y, Inderbitzin D, Leibundgut D. Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure. Anesth Analg. 2009 Jun;108(6):1823-9. doi: 10.1213/ane.0b013e3181a2a8bf.'}, {'pmid': '2868172', 'type': 'BACKGROUND', 'citation': 'Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307-10.'}]}, 'descriptionModule': {'briefSummary': 'Dynamic parameters like pulse pressure Variation (PPV) , synonymous: difference in pulse pressure (dPP), can predict fluid responsiveness reliably (Marik PE et al, Crit Care Med 2009; 37:2642-7). An arterial line is required for assessment of dPP. On a modified Penaz technique, a non-invasive measurement device is now available commercially. In this study, the reference technique based on arterial measurement and a respiratory variation monitor (Pestel G et al, Anesth Analg 2009; 108:1823-9) was compared to the non-invasive device a clinical setting. At defined time points, systolic, diastolic, mean arterial blood pressure and dPP were compared using Bland-Altmann Analysis (Bland JM, Altman DG, Lancet 1986; 1: 307-10)'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'maximumAge': '80 Years', 'minimumAge': '18 Years', 'samplingMethod': 'NON_PROBABILITY_SAMPLE', 'studyPopulation': 'Patients scheduled for elective abdominal or urological surgery', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Age \\> 18 and \\< 80 years old\n* Written informed consent obtained\n* Patients scheduled for elective urological or abdominal surgery procedures in supine position\n* qualifying for arterial line\n\nExclusion Criteria:\n\n* pregnancy\n* cardiac insufficiency (NYHA 4, EF \\< 25 %)\n* coronary artery disease (CCS 4)\n* coagulopathy\n* symptoms of infection or sepsis\n* malignant hyperthermia\n* absence of sinus rhythm\n* BMI \\> 30\n* M. Raynaud'}, 'identificationModule': {'nctId': 'NCT02009020', 'briefTitle': 'Evaluation of a Non-invasive Device to Measure Blood Pressure and Difference in Pulse Pressure (dPP) Intraoperatively', 'organization': {'class': 'OTHER', 'fullName': 'Johannes Gutenberg University Mainz'}, 'orgStudyIdInfo': {'id': '837.531.11 (8073)'}}, 'contactsLocationsModule': {'locations': [{'zip': '55131', 'city': 'Mainz', 'country': 'Germany', 'facility': 'Universitaetsmedizin - Johannes Gutenberg University Mainz (Department of Anesthesiology)', 'geoPoint': {'lat': 49.98185, 'lon': 8.28008}}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Johannes Gutenberg University Mainz', 'class': 'OTHER'}, 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'M.D.', 'investigatorFullName': 'Verena Schnupp', 'investigatorAffiliation': 'Johannes Gutenberg University Mainz'}}}}