Viewing Study NCT04936802


Ignite Creation Date: 2025-12-25 @ 3:56 AM
Ignite Modification Date: 2025-12-26 @ 2:46 AM
Study NCT ID: NCT04936802
Status: UNKNOWN
Last Update Posted: 2021-06-23
First Post: 2021-06-03
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Safety and Feasibility of the Transcatheter Tricuspid Valve Repair System (Trialign)
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D014262', 'term': 'Tricuspid Valve Insufficiency'}], 'ancestors': [{'id': 'D006349', 'term': 'Heart Valve Diseases'}, {'id': 'D006331', 'term': 'Heart Diseases'}, {'id': 'D002318', 'term': 'Cardiovascular Diseases'}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'TREATMENT', 'interventionModel': 'SINGLE_GROUP', 'interventionModelDescription': 'Tricuspid valve repair'}, 'enrollmentInfo': {'type': 'ESTIMATED', 'count': 5}}, 'statusModule': {'overallStatus': 'UNKNOWN', 'lastKnownStatus': 'NOT_YET_RECRUITING', 'startDateStruct': {'date': '2021-06-25', 'type': 'ESTIMATED'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2021-06', 'completionDateStruct': {'date': '2023-06-30', 'type': 'ESTIMATED'}, 'lastUpdateSubmitDate': '2021-06-22', 'studyFirstSubmitDate': '2021-06-03', 'studyFirstSubmitQcDate': '2021-06-22', 'lastUpdatePostDateStruct': {'date': '2021-06-23', 'type': 'ACTUAL'}, 'studyFirstPostDateStruct': {'date': '2021-06-23', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2022-06-30', 'type': 'ESTIMATED'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Severe adverse device events (SADE)', 'timeFrame': '30 days', 'description': 'Severe adverse device events (SADE) , defined as any device related complication, including but not limited to: death, myocardial infarction, stroke, reoperation, renal failure, pulmonary embolism, gastrointestinal bleeding, readmission, etc.'}], 'secondaryOutcomes': [{'measure': 'Technical success', 'timeFrame': '30 days', 'description': 'Technical success, defined as freedom from death with:\n\n1. Successful access, delivery and retrieval of the device delivery system;\n2. Deployment and correct positioning of the intended device(s) which is maintained and;\n3. No need for additional unplanned or emergency surgery or re-intervention related to the device or access procedure.'}, {'measure': 'Evaluation of tricuspid valve function', 'timeFrame': '6 months'}, {'measure': 'New York Heart Association (NYHA) classification', 'timeFrame': '6 months'}, {'measure': '6-minute walk test (6MWT)', 'timeFrame': '6 months'}, {'measure': 'EuroQol five dimensions questionnaire (EQ-5D)', 'timeFrame': '6 months'}, {'measure': 'Incidence of adverse events', 'timeFrame': '6 months'}]}, 'oversightModule': {'oversightHasDmc': False, 'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': False}, 'conditionsModule': {'conditions': ['Tricuspid Regurgitation']}, 'descriptionModule': {'briefSummary': 'The purpose of the study is to demonstrate safety and feasibility of the transcatheter tricuspid valve repair system (Trialign) for the treatment or reduction of moderate to severe functional tricuspid regurgitation.', 'detailedDescription': 'This study is a prospective single-arm trial for transcatheter tricuspid valve repair system (Trialign). A series of physical, imaging and laboratory exams will be performed to determine whether a subject has moderate to severe tricuspid regurgitation with high surgical risk. Subjects who meet the criteria will then receiveTrialign treatment if an informed consent is obtained.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'maximumAge': '85 Years', 'minimumAge': '18 Years', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n1. Subjects has been informed the study and provided written informed consent.\n2. Age ≥ 18 and ≤ 85 years old.\n3. NYHA class II, III or ambulatory IV.\n4. The subject was diagnosed moderate to severe functional tricuspid regurgitation\n5. The subject was at high risk for open heart valve surgery. The heart team recommended tricuspid annuloplasty.\n6. Subjects shall meet all selected criteria for TEE with moderate or severe tricuspid regurgitation.\n\n 1. Systolic pulmonary artery pressure (SPAP) ≤ 60mmHg.\n 2. Left ventricular ejection fraction (LVEF) ≥ 30%.\n 3. Right ventricle tricuspid annular plane systolic excursion (TAPSE) ≥ 15 mm.\n 4. Tricuspid valve annular diameter ≤ 55 mm.\n 5. Tricuspid EROA ≤ 1.75 cm2.\n 6. Functional tricuspid valve regurgitation pathology with a structurally normal valve.\n7. Sufficient posterior annular dimension for device implantation.\n\nExclusion Criteria:\n\n1. Severe uncontrolled hypertension (SBP ≥ 180 mmHg and/or DBP ≥ 110 mmHg).\n2. History of heart transplant.\n3. Previous tricuspid valve repair or replacement (including artificial valve).\n4. Presence of a left ventricular assist device.\n5. Active endocarditis.\n6. Severe degenerative tricuspid valve disease.\n7. Severe aortic stenosis.\n8. The degree of mitral regurgitation is greater than grade 3.\n9. Complete occlusion due to chronic calcification of the right coronary artery.\n10. History of right internal jugular vein occlusion or thrombosis;\n11. Anatomy in the region of the access path (right internal jugular vein) prevented correct placement of a percutaneous tricuspid valve annuloplasty system (e.g.: the presence of spinal stenosis, stent, vascular prosthesis).\n12. An indication of the presence of thrombi in the right ventricle or atrium.\n13. Myocardial infarction (MI) or known unstable angina within the 30 days prior to the index procedure.\n14. Any percutaneous coronary intervention (PCI) within 30 days prior to the index procedure or planned 3 months post-the index procedure.\n15. Hemodynamic instability or cardiogenic shock.\n16. Restrictive or hypertrophic cardiomyopathy. Constructive pericarditis, or other structural heart disease.\n17. Cerebrovascular accident (CVA) within the past 6 months\n18. Serum creatinine \\> 2.5 mg/dL (or 221 μmol/L), Impaired kidney function, defined as glomerular filtration rate (GFR) of 30 mL/min or less.\n19. Anemia (hemoglobin \\<\\<90g/L) not corrected by transfusion. Thrombocytopenia (platelet count \\<100×109/L) or thrombocytosis (\\>750×109/L).\n20. Bleeding disorders or hypercoagulable state.\n21. Active peptic ulcer or active gastrointestinal bleeding.\n22. Contraindication to anticoagulant or antiplatelet therapies.\n23. Contraindications to or refusal of blood transfusions.\n24. Known allergy to stainless steel, nickel, platinum iridium, polyester and/or silk.\n25. Pregnant or lactating; or female of childbearing potential with a positive pregnancy test 24 hours before any study-related radiation exposure.\n26. Life expectancy less than 12 months.\n27. Concurrent use of another clinical study product or use of another clinical study product within 30 days prior to enrolment.\n28. Other circumstances deemed unsuitable for inclusion by the researcher.'}, 'identificationModule': {'nctId': 'NCT04936802', 'briefTitle': 'Safety and Feasibility of the Transcatheter Tricuspid Valve Repair System (Trialign)', 'organization': {'class': 'OTHER', 'fullName': 'Xijing Hospital'}, 'officialTitle': 'Safety and Feasibility of the Transcatheter Tricuspid Valve Repair System (Trialign) for the Treatment or Reduction of Moderate to Severe Functional Tricuspid Regurgitation', 'orgStudyIdInfo': {'id': 'Trialign study'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Transcatheter tricuspid valve repair system (Trialign)', 'description': 'Subjects who received transcatheter tricuspid valve repair with Trialign will be included in this arm.', 'interventionNames': ['Device: Transcatheter tricuspid valve repair system (Trialign)']}], 'interventions': [{'name': 'Transcatheter tricuspid valve repair system (Trialign)', 'type': 'DEVICE', 'description': 'To assess the Trialign System to treat subjects with moderate to severe tricuspid regurgitation', 'armGroupLabels': ['Transcatheter tricuspid valve repair system (Trialign)']}]}, 'contactsLocationsModule': {'centralContacts': [{'name': 'Bo Wang', 'role': 'CONTACT', 'email': 'trialign@163.com', 'phone': '86-18092798759'}], 'overallOfficials': [{'name': 'Ling Tao', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Xijing Hospital'}]}, 'ipdSharingStatementModule': {'ipdSharing': 'NO'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Xijing Hospital', 'class': 'OTHER'}, 'responsibleParty': {'type': 'SPONSOR'}}}}