Raw JSON
{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D008312', 'term': 'Malocclusion, Angle Class II'}], 'ancestors': [{'id': 'D008310', 'term': 'Malocclusion'}, {'id': 'D014076', 'term': 'Tooth Diseases'}, {'id': 'D009057', 'term': 'Stomatognathic Diseases'}]}, 'interventionBrowseModule': {'meshes': [{'id': 'D007834', 'term': 'Lasers'}], 'ancestors': [{'id': 'D055096', 'term': 'Optical Devices'}, {'id': 'D004864', 'term': 'Equipment and Supplies'}, {'id': 'D055618', 'term': 'Radiation Equipment and Supplies'}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'RANDOMIZED', 'maskingInfo': {'masking': 'SINGLE', 'whoMasked': ['INVESTIGATOR']}, 'primaryPurpose': 'TREATMENT', 'interventionModel': 'PARALLEL'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 22}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2019-07-05', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2020-02', 'completionDateStruct': {'date': '2019-11-02', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2020-02-17', 'studyFirstSubmitDate': '2020-02-14', 'studyFirstSubmitQcDate': '2020-02-17', 'lastUpdatePostDateStruct': {'date': '2020-02-19', 'type': 'ACTUAL'}, 'studyFirstPostDateStruct': {'date': '2020-02-19', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2019-10-12', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'stability of orthodontic mini-implants', 'timeFrame': '60 days', 'description': 'The mini-implants stability was estimated employing a Periotest device (Medzintechnik Gulden e K, Modautal, Germany). The Periotest measurement system includes the sound formed from contact between an object and a metallic tapping bar in a handpiece, which is electromagnetically driven and electronically verified. The Periotest response detection is analyzed through a fast Fourier transform (FFT) algorithm. Simply put, the Periotest answer to tapping is estimated by an accelerometer and then analyzed. The signal generated by tapping is then transformed to a value called the Periotest value (PTV), which depends on the damping characteristics of the peri-implant tissue. The Periotest Test values (PTVs) are based on a numerical scale ranging from -8 to +50, defined by mathematical computation. The lower Periotest values indicate higher implant stability and thereupon the higher absorption effect of the target objects.'}], 'secondaryOutcomes': [{'measure': 'Pain level (NRS scale)', 'timeFrame': '24 hours', 'description': 'Each patient received a questionnaire for individual pain assessment (the numeric rating scale, NRS-11, grade level 0-10) immediately following placement of mini-implants. The maximum pain level was measured at both sides of the maxilla during the first day after the treatment. The NRS-11 scale consists of a conscious, subjective assessment of the pain experienced; therefore, it is used in the case of patients over ten years old.\n\n0 = no pain, 1-3 = mild pain, 4-6 = moderate pain, 7-10 = severe pain.'}, {'measure': 'mini-implants loss', 'timeFrame': '60 days', 'description': 'Mini-implants survival rate was assessed during 60 days observation period.'}]}, 'oversightModule': {'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': False}, 'conditionsModule': {'conditions': ['Malocclusion, Angle Class II']}, 'descriptionModule': {'briefSummary': 'The study aimed to evaluate the influence of a 635nm diode laser on the stability of orthodontic mini-implants in vitro, as well as mini-implants failure rate (mini-implant loss) and patients pain level after the treatment. A randomized clinical split-mouth trial was concluded with 22 subjects (14 women, 8 men), 44 orthodontic mini-implants with a diameter 1.4mm and length of 10mm. Mini-implants were placed between teeth 3 and 4; and 13 and 14 (Universal Numbering System), in the area of the attached gingiva, 2 mm below mucogingival junction.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT'], 'maximumAge': '60 Years', 'minimumAge': '18 Years', 'healthyVolunteers': True, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* patients with class II malocclusion defect requiring lateral maxillary teeth distillation based on the use of orthodontic mini-implant;\n* the patients were treated first time using fixed orthodontic appliance;\n* no systemic diseases;\n* were not using anti-inflammatory drugs;\n\nExclusion Criteria:\n\n* had used antibiotics in the previous 24 months;\n* smokers;\n* had history of radiotherapy,\n* taking bisphosphonate medication'}, 'identificationModule': {'nctId': 'NCT04276402', 'briefTitle': 'Effect of Photobiomodulation by 808nm Diode Laser on the Stability of Orthodontic Mini-implants.', 'organization': {'class': 'OTHER', 'fullName': 'Wroclaw Medical University'}, 'officialTitle': 'Effect of Photobiomodulation by 808nm Diode Laser on the Stability of Orthodontic Mini-implants: A Randomized Clinical Split-Mouth Trial.', 'orgStudyIdInfo': {'id': 'WroclawMU3'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Right side of the maxilla', 'interventionNames': ['Procedure: Irradiation of implants with 808nm laser']}, {'type': 'NO_INTERVENTION', 'label': 'Left side of the maxilla'}], 'interventions': [{'name': 'Irradiation of implants with 808nm laser', 'type': 'PROCEDURE', 'description': 'Irradiation of implants with 808nm laser', 'armGroupLabels': ['Right side of the maxilla']}]}, 'contactsLocationsModule': {'locations': [{'city': 'KoĊcian', 'country': 'Poland', 'facility': 'Private Dental Healtcare', 'geoPoint': {'lat': 52.08829, 'lon': 16.64866}}]}, 'ipdSharingStatementModule': {'ipdSharing': 'NO'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Wroclaw Medical University', 'class': 'OTHER'}, 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'Principal Investigator', 'investigatorFullName': 'Jacek Matys', 'investigatorAffiliation': 'Wroclaw Medical University'}}}}