Viewing Study NCT04484805


Ignite Creation Date: 2025-12-25 @ 3:28 AM
Ignite Modification Date: 2025-12-26 @ 2:09 AM
Study NCT ID: NCT04484805
Status: COMPLETED
Last Update Posted: 2024-10-22
First Post: 2020-06-05
Is NOT Gene Therapy: False
Has Adverse Events: True

Brief Title: Socket Cooling Effectiveness Take Home Study
Sponsor:
Organization:

Raw JSON

{'hasResults': True, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24', 'submissionTracking': {'firstMcpInfo': {'postDateStruct': {'date': '2024-09-25', 'type': 'ACTUAL'}}}}, 'conditionBrowseModule': {'meshes': [{'id': 'D014947', 'term': 'Wounds and Injuries'}, {'id': 'D009043', 'term': 'Motor Activity'}], 'ancestors': [{'id': 'D001519', 'term': 'Behavior'}]}}, 'resultsSection': {'moreInfoModule': {'pointOfContact': {'email': 'todd.farrell@liberatingtech.com', 'phone': '774-233-0873', 'title': 'Dr. Todd Farrell', 'organization': 'Liberating Technologies, Inc.'}, 'certainAgreement': {'piSponsorEmployee': True}}, 'adverseEventsModule': {'timeFrame': 'Adverse events were monitored/collected during the experimental conditions. With each condition lasting about 1 month, each participant was monitored for adverse events for about 2 months. Adverse events were monitored/assessed at least every 2 weeks by phone call, with study staff checking in more frequently if participants reached out with questions. Participants were told to reach out to study staff immediately if adverse events did occur.', 'eventGroups': [{'id': 'EG000', 'title': 'ICE Unit', 'description': 'The subject wears the experimental socket with an ICE Unit, which includes a TEC and will be actively cooling the leg whenever the device is powered on. An ambient temperature sensor and step counter is attached to the socket. The subject is only informed that each condition is a "different level of cooling" to reduce bias. This condition should last approximately one month.\n\nICE Condition: Experimental socket integrated with a heat spreader. An ICE Unit (includes TEC) is attached to the socket.', 'otherNumAtRisk': 12, 'deathsNumAtRisk': 12, 'otherNumAffected': 0, 'seriousNumAtRisk': 12, 'deathsNumAffected': 0, 'seriousNumAffected': 0}, {'id': 'EG001', 'title': 'Sham Unit', 'description': 'The subject wears the experimental socket with a Sham Unit, which excludes a TEC and will not be actively cooling the leg when the device is powered on. An ambient temperature sensor and step counter is attached to the socket. The subject is only informed that each condition is a "different level of cooling" to reduce bias. This condition should last approximately one month.\n\nSham Condition: Experimental socket integrated with a heat spreader. A Sham Unit (excludes TEC) is attached to the socket.', 'otherNumAtRisk': 12, 'deathsNumAtRisk': 12, 'otherNumAffected': 0, 'seriousNumAtRisk': 12, 'deathsNumAffected': 0, 'seriousNumAffected': 0}], 'frequencyThreshold': '0'}, 'outcomeMeasuresModule': {'outcomeMeasures': [{'type': 'PRIMARY', 'title': 'Residual Limb Temperature', 'denoms': [{'units': 'Participants', 'counts': [{'value': '12', 'groupId': 'OG000'}, {'value': '12', 'groupId': 'OG001'}]}], 'groups': [{'id': 'OG000', 'title': 'ICE Unit', 'description': 'The subject wears the experimental socket with an ICE Unit, which includes a TEC and will be actively cooling the leg whenever the device is powered on. An ambient temperature sensor and step counter is attached to the socket. The subject is only informed that each condition is a "different level of cooling" to reduce bias. This condition should last approximately one month.\n\nICE Condition: Experimental socket integrated with a heat spreader. An ICE Unit (includes TEC) is attached to the socket.'}, {'id': 'OG001', 'title': 'Sham Unit', 'description': 'The subject wears the experimental socket with a Sham Unit, which excludes a TEC and will not be actively cooling the leg when the device is powered on. An ambient temperature sensor and step counter is attached to the socket. The subject is only informed that each condition is a "different level of cooling" to reduce bias. This condition should last approximately one month.\n\nSham Condition: Experimental socket integrated with a heat spreader. A Sham Unit (excludes TEC) is attached to the socket.'}], 'classes': [{'categories': [{'measurements': [{'value': '-2.3', 'spread': '0.9', 'groupId': 'OG000'}, {'value': '1.9', 'spread': '2.0', 'groupId': 'OG001'}]}]}], 'paramType': 'MEAN', 'timeFrame': '4 hours', 'description': 'This will be tested only during in-lab visits. An intervention of the experimental socket with the ICE cooling unit should yield at least a 2 degree Celsius decrease in temperature compared with no intervention. This will be tested in-lab with 6 thermocouples taped to the residual limb while the subject is sitting and walking on a treadmill.\n\nThe reported result is the temperature difference of the residual limb from the baseline temperature (before activity) to the end of the sitting period (after activity). The ICE or Sham unit is turned on 5 minutes before the 15 minute walking period. After the 15 minute walking period, the participant sits with the unit ON for 45 minutes. The baseline temperature reading is taken directly before the unit is turned on, and the end temperature reading is taken after the 45 minutes of sitting.', 'unitOfMeasure': 'Avg Temp Diff from Baseline (Degrees C)', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED'}]}, 'participantFlowModule': {'groups': [{'id': 'FG000', 'title': 'ICE Unit First, Then Sham Unit', 'description': 'The subject wears the experimental socket with an ICE Unit, which includes a TEC and will be actively cooling the leg whenever the device is powered on. An ambient temperature sensor and step counter is attached to the socket. The subject is only informed that each condition is a "different level of cooling" to reduce bias. This condition should last approximately one month.\n\nThe subject is then swapped to the Sham condition, which is the same setup as above except it excludes a TEC and will not be actively cooling the leg when the device is powered on. They will be in this condition for approximately one month.\n\nICE Condition: Experimental socket integrated with a heat spreader. An ICE Unit (includes TEC) is attached to the socket.\n\nSham Condition: Experimental socket integrated with a heat spreader. A Sham Unit (excludes TEC) is attached to the socket.'}, {'id': 'FG001', 'title': 'Sham Unit First, Then ICE Unit', 'description': 'The subject wears the experimental socket with a Sham Unit, which excludes a TEC and will not be actively cooling the leg when the device is powered on. An ambient temperature sensor and step counter is attached to the socket. The subject is only informed that each condition is a "different level of cooling" to reduce bias. This condition should last approximately one month.\n\nThe subject is then swapped to the ICE condition, which is the same setup as above except it includes a TEC and will be actively cooling the leg when the device is powered on. They will be in this condition for approximately one month.\n\nICE Condition: Experimental socket integrated with a heat spreader. An ICE Unit (includes TEC) is attached to the socket.\n\nSham Condition: Experimental socket integrated with a heat spreader. A Sham Unit (excludes TEC) is attached to the socket.'}], 'periods': [{'title': 'Overall Study', 'milestones': [{'type': 'STARTED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '6'}, {'groupId': 'FG001', 'numSubjects': '6'}]}, {'type': 'COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '4'}, {'groupId': 'FG001', 'numSubjects': '6'}]}, {'type': 'NOT COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '2'}, {'groupId': 'FG001', 'numSubjects': '0'}]}], 'dropWithdraws': [{'type': 'LTI_H01 piloted the device and was too familiar with the study design to be unblinded/analyzed', 'reasons': [{'groupId': 'FG000', 'numSubjects': '1'}, {'groupId': 'FG001', 'numSubjects': '0'}]}, {'type': 'LTI_H02 had socket fit issues causing discomfort which caused us to withdraw them from the study.', 'reasons': [{'groupId': 'FG000', 'numSubjects': '1'}, {'groupId': 'FG001', 'numSubjects': '0'}]}]}]}, 'baselineCharacteristicsModule': {'denoms': [{'units': 'Participants', 'counts': [{'value': '6', 'groupId': 'BG000'}, {'value': '6', 'groupId': 'BG001'}, {'value': '12', 'groupId': 'BG002'}]}], 'groups': [{'id': 'BG000', 'title': 'ICE Unit, Then Sham Unit', 'description': 'The subject wears the experimental socket with an ICE Unit, which includes a TEC and will be actively cooling the leg whenever the device is powered on. An ambient temperature sensor and step counter is attached to the socket. The subject is only informed that each condition is a "different level of cooling" to reduce bias. This condition should last approximately one month.\n\nThe subject is then swapped to the Sham condition, which is the same setup as above except it excludes a TEC and will not be actively cooling the leg when the device is powered on. They will be in this condition for approximately one month.\n\nICE Condition: Experimental socket integrated with a heat spreader. An ICE Unit (includes TEC) is attached to the socket.\n\nSham Condition: Experimental socket integrated with a heat spreader. A Sham Unit (excludes TEC) is attached to the socket.'}, {'id': 'BG001', 'title': 'Sham Unit, Then ICE Unit', 'description': 'The subject wears the experimental socket with a Sham Unit, which excludes a TEC and will not be actively cooling the leg when the device is powered on. An ambient temperature sensor and step counter is attached to the socket. The subject is only informed that each condition is a "different level of cooling" to reduce bias. This condition should last approximately one month.\n\nThe subject is then swapped to the ICE condition, which is the same setup as above except it includes a TEC and will be actively cooling the leg when the device is powered on. They will be in this condition for approximately one month.\n\nICE Condition: Experimental socket integrated with a heat spreader. An ICE Unit (includes TEC) is attached to the socket.\n\nSham Condition: Experimental socket integrated with a heat spreader. A Sham Unit (excludes TEC) is attached to the socket.'}, {'id': 'BG002', 'title': 'Total', 'description': 'Total of all reporting groups'}], 'measures': [{'title': 'Age, Categorical', 'classes': [{'categories': [{'title': '<=18 years', 'measurements': [{'value': '0', 'groupId': 'BG000'}, {'value': '0', 'groupId': 'BG001'}, {'value': '0', 'groupId': 'BG002'}]}, {'title': 'Between 18 and 65 years', 'measurements': [{'value': '4', 'groupId': 'BG000'}, {'value': '5', 'groupId': 'BG001'}, {'value': '9', 'groupId': 'BG002'}]}, {'title': '>=65 years', 'measurements': [{'value': '2', 'groupId': 'BG000'}, {'value': '1', 'groupId': 'BG001'}, {'value': '3', 'groupId': 'BG002'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Sex: Female, Male', 'classes': [{'categories': [{'title': 'Female', 'measurements': [{'value': '1', 'groupId': 'BG000'}, {'value': '0', 'groupId': 'BG001'}, {'value': '1', 'groupId': 'BG002'}]}, {'title': 'Male', 'measurements': [{'value': '5', 'groupId': 'BG000'}, {'value': '6', 'groupId': 'BG001'}, {'value': '11', 'groupId': 'BG002'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Race (NIH/OMB)', 'classes': [{'categories': [{'title': 'American Indian or Alaska Native', 'measurements': [{'value': '0', 'groupId': 'BG000'}, {'value': '0', 'groupId': 'BG001'}, {'value': '0', 'groupId': 'BG002'}]}, {'title': 'Asian', 'measurements': [{'value': '0', 'groupId': 'BG000'}, {'value': '0', 'groupId': 'BG001'}, {'value': '0', 'groupId': 'BG002'}]}, {'title': 'Native Hawaiian or Other Pacific Islander', 'measurements': [{'value': '0', 'groupId': 'BG000'}, {'value': '0', 'groupId': 'BG001'}, {'value': '0', 'groupId': 'BG002'}]}, {'title': 'Black or African American', 'measurements': [{'value': '0', 'groupId': 'BG000'}, {'value': '0', 'groupId': 'BG001'}, {'value': '0', 'groupId': 'BG002'}]}, {'title': 'White', 'measurements': [{'value': '6', 'groupId': 'BG000'}, {'value': '6', 'groupId': 'BG001'}, {'value': '12', 'groupId': 'BG002'}]}, {'title': 'More than one race', 'measurements': [{'value': '0', 'groupId': 'BG000'}, {'value': '0', 'groupId': 'BG001'}, {'value': '0', 'groupId': 'BG002'}]}, {'title': 'Unknown or Not Reported', 'measurements': [{'value': '0', 'groupId': 'BG000'}, {'value': '0', 'groupId': 'BG001'}, {'value': '0', 'groupId': 'BG002'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Region of Enrollment', 'classes': [{'title': 'United States', 'categories': [{'measurements': [{'value': '6', 'groupId': 'BG000'}, {'value': '6', 'groupId': 'BG001'}, {'value': '12', 'groupId': 'BG002'}]}]}], 'paramType': 'NUMBER', 'unitOfMeasure': 'participants'}]}}, 'documentSection': {'largeDocumentModule': {'noSap': True, 'largeDocs': [{'date': '2019-07-12', 'size': 880630, 'label': 'Study Protocol', 'hasIcf': False, 'hasSap': False, 'filename': 'Prot_001.pdf', 'typeAbbrev': 'Prot', 'uploadDate': '2024-09-30T15:52', 'hasProtocol': True}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'RANDOMIZED', 'maskingInfo': {'masking': 'DOUBLE', 'whoMasked': ['PARTICIPANT', 'INVESTIGATOR']}, 'primaryPurpose': 'OTHER', 'interventionModel': 'CROSSOVER'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 12}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2019-08-01', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2024-10', 'completionDateStruct': {'date': '2020-11-03', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2024-10-01', 'studyFirstSubmitDate': '2020-06-05', 'resultsFirstSubmitDate': '2024-08-28', 'studyFirstSubmitQcDate': '2020-07-20', 'lastUpdatePostDateStruct': {'date': '2024-10-22', 'type': 'ACTUAL'}, 'resultsFirstSubmitQcDate': '2024-10-01', 'studyFirstPostDateStruct': {'date': '2020-07-24', 'type': 'ACTUAL'}, 'resultsFirstPostDateStruct': {'date': '2024-10-22', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2020-11-03', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Residual Limb Temperature', 'timeFrame': '4 hours', 'description': 'This will be tested only during in-lab visits. An intervention of the experimental socket with the ICE cooling unit should yield at least a 2 degree Celsius decrease in temperature compared with no intervention. This will be tested in-lab with 6 thermocouples taped to the residual limb while the subject is sitting and walking on a treadmill.\n\nThe reported result is the temperature difference of the residual limb from the baseline temperature (before activity) to the end of the sitting period (after activity). The ICE or Sham unit is turned on 5 minutes before the 15 minute walking period. After the 15 minute walking period, the participant sits with the unit ON for 45 minutes. The baseline temperature reading is taken directly before the unit is turned on, and the end temperature reading is taken after the 45 minutes of sitting.'}]}, 'oversightModule': {'oversightHasDmc': False, 'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': True}, 'conditionsModule': {'keywords': ['cooling', 'amputee', 'lower limb absence', 'prosthesis', 'prosthetic leg', 'transtibial', 'below knee amputation', 'lower limb difference', 'lower limb loss', 'socket', 'prosthetist', 'sweat', 'active', 'walking', 'prosthetic liner', 'prosthetic sock', 'perspiration', 'moisture', 'heat', 'thermal'], 'conditions': ['Amputation', 'Amputation; Traumatic, Leg, Lower', 'Amputation Stump', 'Limb; Absence, Congenital, Lower', 'Prosthesis User', 'Lower Limb Amputation Below Knee (Injury)']}, 'descriptionModule': {'briefSummary': 'The comfort and fit of the residual limb within a prosthetic socket are of primary concern for many amputees. The residual limb is typically covered by non-breathable and non- thermally conductive materials that can create a warm and ultimately moist environment.\n\nTo address this, Liberating Technologies, Inc. (LTI) and Vivonics, Inc. have developed a thermo-electric cooling (TEC)-based module called the Intrasocket Cooling Element (ICE), that can be embedded into the prosthesis in order to cool the residual limb. A technology that can provide thermal control while retaining adequate suspension, weight and other prosthetic characteristics would benefit many prosthesis wearers.', 'detailedDescription': 'The comfort and fit of the residual limb within a prosthetic socket are of primary concern for many amputees. The residual limb is typically covered by non-breathable and non- thermally conductive materials that can create a warm and ultimately moist environment. Studies found increases in socket temperature after the prosthesis was donned (0.8 degrees C) and after 30 minutes of walking (2.5 degrees C). Temperatures were found to remain elevated long after activity cessation and even a rest period of double the duration of the preceding activity period is insufficient to return the limb to its initial temperature. A study suggested that a modest temperature increase of only 2 degrees C may be responsible for reports of thermal discomfort by amputees. Therefore, a small amount of activity can cause the socket temperature to elevate and remain at an uncomfortable level for an extended period of time, which can lead to decreased wear times. In summary, an uncomfortable socket/residual limb interface decreases prosthesis use among amputees who want to remain active in their lives.\n\nTo address this, Liberating Technologies, Inc. (LTI) and Vivonics, Inc. have developed a thermo-electric cooling (TEC)-based module called the Intrasocket Cooling Element (ICE), that can be embedded into the prosthesis in order to cool the residual limb. A technology that can provide thermal control while retaining adequate suspension, weight and other prosthetic characteristics would benefit many prosthesis wearers.\n\nThis study will focus on investigating the efficacy of this novel socket cooling technology.\n\nThe rationale for this study is to determine how well the new technology can cool the residual limb not only in a controlled laboratory environment, but also in a home environment where the device would ultimately be utilized.\n\nThe primary objective of this study is to measure the effects of cooling the residual limb on quality of life (QoL) and functional outcomes. Cooling the residual limb inside the prosthetic socket would result in less sweating and greater comfort while wearing the prosthesis, and ultimately greater function and better quality of life as measured by standard functional and QoL outcome measures.\n\nA two group, prospective, double-blinded, block randomized, crossover study design will be implemented. Research participants will be consented and have baseline activity and socket temperature data collected from their usual prosthesis during normal use (4 weeks). The ICE system will be integrated into a custom, experimental socket for each subject. Two versions of the cooling module will be created: (1) a fully-functional, active ICE cooling module (the so called "ON", or experimental, condition), and (2) a placebo ICE module with the TEC unit replaced with an insulating material layer between the fan and the heat spreader such that even when the system is turned on, minimal heat transfer occurs (the control, or "OFF" condition). An ICE module with a heat spreader will be embedded into the socket and the fan will continue to run whether or not active cooling is engaged for both test conditions; however, no heat will be able to be transferred through the insulating layer in the OFF condition. The TEC inside the ICE unit will not be visible once assembled and the modules will be assembled independently; therefore, both the subject and the tester will be blinded to the condition being tested for both the in-lab and at-home testing. A serial number will be used to identify the assembled units and the master key stored separately.\n\nThe participants will be divided into two groups and the order of the experimental conditions will be randomized. Each condition will be tested for 4 weeks. In-lab testing and functional measures will be assessed between testing periods as additional assessments of efficacy of the device. Testing will consist of 4 test site visits, as well as 1-2 visits to create and align the experimental socket. The entire study will continue for 3 months.\n\nLower limb prosthesis users will be recruited for the study and consented with an approved protocol. Research participants will represent a convenience sample and will reflect the local population of both above-knee (AK) and below-knee (BK) amputees of various K-levels using a variety of suspension types who could benefit from temperature control within the socket.\n\nA maximum of 20 subjects will be recruited for this study. This is increased from the target 16 subjects to account for any drop-outs, etc.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'maximumAge': '89 Years', 'minimumAge': '18 Years', 'healthyVolunteers': True, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Must have a lower limb absence\n* Willing and able to complete outlined tasks\n* Must complete and pass our Semmes-Weinstein monofilament test\n* Must understand English in order to be properly consented and provide feedback to the study personnel\n\nExclusion Criteria:\n\n* The risks to pregnant women and fetuses are unknown and therefore pregnant women should not participate in the study\n* No symptoms consistent with peripheral neuropathy or other sensory diagnosis that could prevent them from feeling the temperature of their limb'}, 'identificationModule': {'nctId': 'NCT04484805', 'briefTitle': 'Socket Cooling Effectiveness Take Home Study', 'organization': {'class': 'INDUSTRY', 'fullName': 'Liberating Technologies, Inc.'}, 'officialTitle': 'Continuation of the Development of Moisture Management Liner and Active Cooling System for Improving Residual Limb Skin Care', 'orgStudyIdInfo': {'id': '120180039'}, 'secondaryIdInfos': [{'id': 'W81XW-17-C-005', 'type': 'OTHER', 'domain': 'DoD'}]}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'ICE Unit', 'description': 'The subject wears the experimental socket with an ICE Unit, which includes a TEC and will be actively cooling the leg whenever the device is powered on. An ambient temperature sensor and step counter is attached to the socket. The subject is only informed that each condition is a "different level of cooling" to reduce bias. This condition should last approximately one month.', 'interventionNames': ['Device: ICE Condition']}, {'type': 'SHAM_COMPARATOR', 'label': 'Sham Unit', 'description': 'The subject wears the experimental socket with a Sham Unit, which excludes a TEC and will not be actively cooling the leg when the device is powered on. An ambient temperature sensor and step counter is attached to the socket. The subject is only informed that each condition is a "different level of cooling" to reduce bias. This condition should last approximately one month.', 'interventionNames': ['Device: Sham Condition']}], 'interventions': [{'name': 'ICE Condition', 'type': 'DEVICE', 'otherNames': ['Cooling Unit', 'ICE Unit'], 'description': 'Experimental socket integrated with a heat spreader. An ICE Unit (includes TEC) is attached to the socket.', 'armGroupLabels': ['ICE Unit']}, {'name': 'Sham Condition', 'type': 'DEVICE', 'otherNames': ['Sham Unit'], 'description': 'Experimental socket integrated with a heat spreader. A Sham Unit (excludes TEC) is attached to the socket.', 'armGroupLabels': ['Sham Unit']}]}, 'contactsLocationsModule': {'locations': [{'zip': '01746', 'city': 'Holliston', 'state': 'Massachusetts', 'country': 'United States', 'facility': 'Liberating Technologies, Inc.', 'geoPoint': {'lat': 42.2001, 'lon': -71.4245}}, {'zip': '55417', 'city': 'Minneapolis', 'state': 'Minnesota', 'country': 'United States', 'facility': 'Minneapolis VA', 'geoPoint': {'lat': 44.97997, 'lon': -93.26384}}]}, 'ipdSharingStatementModule': {'ipdSharing': 'UNDECIDED'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Liberating Technologies, Inc.', 'class': 'INDUSTRY'}, 'collaborators': [{'name': 'Vivonics, Inc.', 'class': 'INDUSTRY'}], 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'Director of Research', 'investigatorFullName': 'Todd Farrell', 'investigatorAffiliation': 'Liberating Technologies, Inc.'}}}}