Viewing Study NCT01737333


Ignite Creation Date: 2025-12-25 @ 3:00 AM
Ignite Modification Date: 2026-03-02 @ 10:10 PM
Study NCT ID: NCT01737333
Status: COMPLETED
Last Update Posted: 2013-09-30
First Post: 2012-11-20
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Multidetector Computed Tomography (MDCT) Tailored Protocol
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'protocolSection': {'designModule': {'studyType': 'OBSERVATIONAL', 'designInfo': {'timePerspective': 'PROSPECTIVE', 'observationalModel': 'CASE_ONLY'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 1493}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2012-10'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2013-09', 'completionDateStruct': {'date': '2013-07', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2013-09-27', 'studyFirstSubmitDate': '2012-11-20', 'studyFirstSubmitQcDate': '2012-11-27', 'lastUpdatePostDateStruct': {'date': '2013-09-30', 'type': 'ESTIMATED'}, 'studyFirstPostDateStruct': {'date': '2012-11-29', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2013-07', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Diagnostic Quality', 'timeFrame': 'Immediately after the single injection of contrast agent', 'description': 'Images are to be assessed according to the following scale: 0=Uninterpretable (Image quality severely affected by motion artifacts or technical reasons; need to repeat the examination); 1=Insufficient (Impaired image quality precludes adequate diagnostic assessment because of severe image noise or insufficient contrast enhancement; need to repeat the examination); 2=Adequate (Image quality in terms of noise and contrast enhancement does not interfere with sufficient diagnostic assessment; delineation of small structures may be suboptimal); or 3=Good (Absent or minimal image noise and good contrast enhancement allow adequate diagnostic assessment with clear delineation of even small structures).'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'conditions': ['Patients Undergoing Contrast Enhanced Multidetector Computed Tomography of the Chest, Abdomen, Liver or Aorta for Any Diagnostic Cause']}, 'descriptionModule': {'briefSummary': 'Collection of data from different sites regardless of whether they use standard or tailored protocols for the application of high concentration iodinated contrast agents to assess if the individually patient-adapted protocols result in a similar diagnostic image quality.', 'detailedDescription': 'To record technical information and compare image quality regarding routine MDCT procedures with contrast administration using a tailored contrast injection and radiation dose protocol. The hypotheses are that the tailored protocols lead to a lower applied mean radiation dose compared to the use of standard protocols and will provide a more standardized contrast dose per patient size without impairing diagnostic quality.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '18 Years', 'samplingMethod': 'PROBABILITY_SAMPLE', 'studyPopulation': 'Patients undergoing MDCT of the abdomen, liver, chest or aorta and receiving high iodinated contrast agents', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* At least 18 years of age\n* Scheduled to undergo contrast enhanced MDCT of the abdomen, liver, aorta, or chest\n* Provides written informed consent\n\nExclusion Criteria:\n\n* Previously enrolled and completed the study\n* Known allergy to iodinated contrast media\n* Pregnancy or lactation\n* Clinically unsuitable for the study'}, 'identificationModule': {'nctId': 'NCT01737333', 'briefTitle': 'Multidetector Computed Tomography (MDCT) Tailored Protocol', 'organization': {'class': 'INDUSTRY', 'fullName': 'Bracco Diagnostics, Inc'}, 'officialTitle': 'A Multicenter, Multinational, Randomized Study of Standard vs. Patient-Adapted Protocols in Multidetector Computed Tomography (MDCT) of the Chest, Abdomen, Liver or Aorta', 'orgStudyIdInfo': {'id': 'IOPM-101'}}, 'contactsLocationsModule': {'locations': [{'zip': '28203', 'city': 'Charlotte', 'state': 'North Carolina', 'country': 'United States', 'facility': 'Department of Radiology Carolinas Medical Center', 'geoPoint': {'lat': 35.22709, 'lon': -80.84313}}, {'zip': '20162', 'city': 'Milan', 'country': 'Italy', 'facility': 'Oepedale Niguarda', 'geoPoint': {'lat': 45.46427, 'lon': 9.18951}}], 'overallOfficials': [{'name': 'Martin Krix, M.D.', 'role': 'STUDY_DIRECTOR', 'affiliation': 'Bracco Diagnostics, Inc'}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Bracco Diagnostics, Inc', 'class': 'INDUSTRY'}, 'responsibleParty': {'type': 'SPONSOR'}}}}