Raw JSON
{'hasResults': True, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24', 'submissionTracking': {'firstMcpInfo': {'postDateStruct': {'date': '2024-09-05', 'type': 'ACTUAL'}}}}, 'conditionBrowseModule': {'meshes': [{'id': 'D006259', 'term': 'Craniocerebral Trauma'}], 'ancestors': [{'id': 'D020196', 'term': 'Trauma, Nervous System'}, {'id': 'D009422', 'term': 'Nervous System Diseases'}, {'id': 'D014947', 'term': 'Wounds and Injuries'}]}}, 'resultsSection': {'moreInfoModule': {'pointOfContact': {'email': 'doreen_steed@med.unc.edu', 'phone': '919-966-0188', 'title': 'Doreen Steed, R.T. (R)(M)', 'organization': 'University of North Carolina at Chapel Hill'}, 'certainAgreement': {'piSponsorEmployee': True}}, 'adverseEventsModule': {'timeFrame': "Each participant assessed for AE's from the time of signing informed consent through the end of the single one-hour visit.", 'eventGroups': [{'id': 'EG000', 'title': 'Head Trauma or Brain Bleed', 'description': 'Medically stable patients who have undergone conventional head CT imaging undergo imaging within 24 hours using the s-HCT system.\n\nStationary Head CT (s-HCT): The system consists of a total of three x-ray sources and nine x-ray detectors with an estimation of approximately 150 projection angles per slice, with less than a minute per slice reconstruction. Radiation dose will be configured as to not exceed that of a conventional head CT, or 2 mSv. The subjects will be positioned on a medical procedure table that will move the subject through the scanning system at the rate of roughly 1 cm per second, during which the necessary x-ray projections will be acquired. The head will be positioned in a carbon fiber head holder from a clinical CT scanner that is secured to the table.', 'otherNumAtRisk': 17, 'deathsNumAtRisk': 17, 'otherNumAffected': 0, 'seriousNumAtRisk': 17, 'deathsNumAffected': 0, 'seriousNumAffected': 0}], 'frequencyThreshold': '0'}, 'outcomeMeasuresModule': {'outcomeMeasures': [{'type': 'PRIMARY', 'title': 'Sensitivity of Stationary Head CT for the Detection of a Hemorrhage', 'denoms': [{'units': 'Participants', 'counts': [{'value': '17', 'groupId': 'OG000'}]}, {'units': 'CT Scans', 'counts': [{'value': '17', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Head Trauma or Brain Bleed', 'description': 'Medically stable patients who have undergone conventional head CT imaging undergo imaging within 24 hours using the s-HCT system.\n\nStationary Head CT (s-HCT): The system consists of a total of three x-ray sources and nine x-ray detectors with an estimation of approximately 150 projection angles per slice, with less than a minute per slice reconstruction. Radiation dose will be configured as to not exceed that of a conventional head CT, or 2 mSv. The subjects will be positioned on a medical procedure table that will move the subject through the scanning system at the rate of roughly 1 cm per second, during which the necessary x-ray projections will be acquired. The head will be positioned in a carbon fiber head holder from a clinical CT scanner that is secured to the table.'}], 'classes': [{'categories': [{'measurements': [{'value': '33', 'spread': '29', 'groupId': 'OG000'}]}]}], 'analyses': [{'pValue': '<0.0001', 'groupIds': ['OG000'], 'statisticalMethod': 'ANOVA', 'nonInferiorityType': 'EQUIVALENCE', 'nonInferiorityComment': 'The equivalence margin was defined through power calculations based on sample size, power of 0.90 and alpha of 0.05 resulting in a margin of +/- 0.26.'}], 'paramType': 'MEAN', 'timeFrame': 'Upon completion of all study image data collection for all participants [each participant was assessed approximately 1 hour for the duration of the single one-hour visit]', 'description': 'Sensitivity of stationary head CT for the detection of a hemorrhage using a reader study is defined as the ability of readers (radiologists) to use the stationary head CT to predict hemorrhage using conventional head CT as the gold standard. All stationary head CT scans will be reviewed in a standardized reader study at the conclusion of all study imaging.', 'unitOfMeasure': 'percent accurately predicted', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'typeUnitsAnalyzed': 'CT Scans', 'denomUnitsSelected': 'CT Scans'}, {'type': 'PRIMARY', 'title': 'Specificity of Stationary Head CT for the Detection of a Hemorrhage', 'denoms': [{'units': 'Participants', 'counts': [{'value': '17', 'groupId': 'OG000'}]}, {'units': 'CT Scans', 'counts': [{'value': '17', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Head Trauma or Brain Bleed', 'description': 'Medically stable patients who have undergone conventional head CT imaging undergo imaging within 24 hours using the s-HCT system.\n\nStationary Head CT (s-HCT): The system consists of a total of three x-ray sources and nine x-ray detectors with an estimation of approximately 150 projection angles per slice, with less than a minute per slice reconstruction. Radiation dose will be configured as to not exceed that of a conventional head CT, or 2 mSv. The subjects will be positioned on a medical procedure table that will move the subject through the scanning system at the rate of roughly 1 cm per second, during which the necessary x-ray projections will be acquired. The head will be positioned in a carbon fiber head holder from a clinical CT scanner that is secured to the table.'}], 'classes': [{'categories': [{'measurements': [{'value': '98', 'spread': '4', 'groupId': 'OG000'}]}]}], 'analyses': [{'pValue': '0.41', 'groupIds': ['OG000'], 'statisticalMethod': 'ANOVA', 'nonInferiorityType': 'EQUIVALENCE', 'nonInferiorityComment': 'The equivalence margin was defined through power calculations based on sample size, power of 0.90 and alpha of 0.05 resulting in a margin of +/- 0.26.'}], 'paramType': 'MEAN', 'timeFrame': 'Upon completion of all study image data collection for all participants [each participant was assessed approximately 1 hour for the duration of the single one-hour visit]', 'description': 'Specificity of stationary head CT for the detection of a hemorrhage using a reader study is defined as the ability of readers (radiologists) to use the stationary head CT to distinguish between individuals that do not have a hemorrhage using conventional head CT as the gold standard. All stationary head CT scans will be reviewed in a standardized reader study at the conclusion of all study imaging.', 'unitOfMeasure': 'percent accurately identified', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'typeUnitsAnalyzed': 'CT Scans', 'denomUnitsSelected': 'CT Scans'}, {'type': 'PRIMARY', 'title': 'Sensitivity of Stationary Head CT for the Detection of a Fracture', 'denoms': [{'units': 'Participants', 'counts': [{'value': '17', 'groupId': 'OG000'}]}, {'units': 'CT Scans', 'counts': [{'value': '17', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Head Trauma or Brain Bleed', 'description': 'Medically stable patients who have undergone conventional head CT imaging undergo imaging within 24 hours using the s-HCT system.\n\nStationary Head CT (s-HCT): The system consists of a total of three x-ray sources and nine x-ray detectors with an estimation of approximately 150 projection angles per slice, with less than a minute per slice reconstruction. Radiation dose will be configured as to not exceed that of a conventional head CT, or 2 mSv. The subjects will be positioned on a medical procedure table that will move the subject through the scanning system at the rate of roughly 1 cm per second, during which the necessary x-ray projections will be acquired. The head will be positioned in a carbon fiber head holder from a clinical CT scanner that is secured to the table.'}], 'classes': [{'categories': [{'measurements': [{'value': '32', 'spread': '16', 'groupId': 'OG000'}]}]}], 'analyses': [{'pValue': '0.0001', 'groupIds': ['OG000'], 'statisticalMethod': 'ANOVA', 'nonInferiorityType': 'EQUIVALENCE', 'nonInferiorityComment': 'The equivalence margin was defined through power calculations based on sample size, power of 0.90 and alpha of 0.05 resulting in a margin of +/- 0.26.'}], 'paramType': 'MEAN', 'timeFrame': 'Upon completion of all study image data collection for all participants [each participant was assessed approximately 1 hour for the duration of the single one-hour visit]', 'description': 'Sensitivity of stationary head CT for the detection of a fracture using a reader study is defined as the ability of readers (radiologists) to use the stationary head CT to predict a fracture using conventional head CT as the gold standard. All stationary head CT scans will be reviewed in a standardized reader study at the conclusion of all study imaging.', 'unitOfMeasure': 'percent accurately predicted', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'typeUnitsAnalyzed': 'CT Scans', 'denomUnitsSelected': 'CT Scans'}, {'type': 'PRIMARY', 'title': 'Specificity of Stationary Head CT for the Detection of a Fracture', 'denoms': [{'units': 'Participants', 'counts': [{'value': '17', 'groupId': 'OG000'}]}, {'units': 'CT Scans', 'counts': [{'value': '17', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Head Trauma or Brain Bleed', 'description': 'Medically stable patients who have undergone conventional head CT imaging undergo imaging within 24 hours using the s-HCT system.\n\nStationary Head CT (s-HCT): The system consists of a total of three x-ray sources and nine x-ray detectors with an estimation of approximately 150 projection angles per slice, with less than a minute per slice reconstruction. Radiation dose will be configured as to not exceed that of a conventional head CT, or 2 mSv. The subjects will be positioned on a medical procedure table that will move the subject through the scanning system at the rate of roughly 1 cm per second, during which the necessary x-ray projections will be acquired. The head will be positioned in a carbon fiber head holder from a clinical CT scanner that is secured to the table.'}], 'classes': [{'categories': [{'measurements': [{'value': '16', 'spread': '10', 'groupId': 'OG000'}]}]}], 'analyses': [{'pValue': '0.0001', 'groupIds': ['OG000'], 'statisticalMethod': 'ANOVA', 'nonInferiorityType': 'EQUIVALENCE', 'nonInferiorityComment': 'The equivalence margin was defined through power calculations based on sample size, power of 0.90 and alpha of 0.05 resulting in a margin of +/- 0.26.'}], 'paramType': 'MEAN', 'timeFrame': 'Upon completion of all study image data collection for all participants [each participant was assessed approximately 1 hour for the duration of the single one-hour visit]', 'description': 'Specificity of stationary head CT for the detection of a fracture using a reader study is defined as the ability of readers (radiologists) to use the stationary head CT to distinguish between individuals that do not have a fracture using conventional head CT as the gold standard. All stationary head CT scans will be reviewed in a standardized reader study at the conclusion of all study imaging.', 'unitOfMeasure': 'percent accurately identified', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'typeUnitsAnalyzed': 'CT Scans', 'denomUnitsSelected': 'CT Scans'}]}, 'participantFlowModule': {'groups': [{'id': 'FG000', 'title': 'Head Trauma or Brain Bleed', 'description': 'Medically stable patients who have undergone conventional head CT imaging undergo imaging within 24 hours using the s-HCT system.\n\nStationary Head CT (s-HCT): The system consists of a total of three x-ray sources and nine x-ray detectors with an estimation of approximately 150 projection angles per slice, with less than a minute per slice reconstruction. Radiation dose will be configured as to not exceed that of a conventional head CT, or 2 mSv. The subjects will be positioned on a medical procedure table that will move the subject through the scanning system at the rate of roughly 1 cm per second, during which the necessary x-ray projections will be acquired. The head will be positioned in a carbon fiber head holder from a clinical CT scanner that is secured to the table.'}], 'periods': [{'title': 'Overall Study', 'milestones': [{'type': 'STARTED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '17'}]}, {'type': 'COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '17'}]}, {'type': 'NOT COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '0'}]}]}]}, 'baselineCharacteristicsModule': {'denoms': [{'units': 'Participants', 'counts': [{'value': '17', 'groupId': 'BG000'}]}], 'groups': [{'id': 'BG000', 'title': 'Head Trauma or Brain Bleed', 'description': 'Medically stable patients who have undergone conventional head CT imaging undergo imaging within 24 hours using the s-HCT system.\n\nStationary Head CT (s-HCT): The system consists of a total of three x-ray sources and nine x-ray detectors with an estimation of approximately 150 projection angles per slice, with less than a minute per slice reconstruction. Radiation dose will be configured as to not exceed that of a conventional head CT, or 2 mSv. The subjects will be positioned on a medical procedure table that will move the subject through the scanning system at the rate of roughly 1 cm per second, during which the necessary x-ray projections will be acquired. The head will be positioned in a carbon fiber head holder from a clinical CT scanner that is secured to the table.'}], 'measures': [{'title': 'Age, Categorical', 'classes': [{'categories': [{'title': '<=18 years', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Between 18 and 65 years', 'measurements': [{'value': '9', 'groupId': 'BG000'}]}, {'title': '>=65 years', 'measurements': [{'value': '8', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Sex: Female, Male', 'classes': [{'categories': [{'title': 'Female', 'measurements': [{'value': '9', 'groupId': 'BG000'}]}, {'title': 'Male', 'measurements': [{'value': '8', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Ethnicity (NIH/OMB)', 'classes': [{'categories': [{'title': 'Hispanic or Latino', 'measurements': [{'value': '2', 'groupId': 'BG000'}]}, {'title': 'Not Hispanic or Latino', 'measurements': [{'value': '14', 'groupId': 'BG000'}]}, {'title': 'Unknown or Not Reported', 'measurements': [{'value': '1', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Race (NIH/OMB)', 'classes': [{'categories': [{'title': 'American Indian or Alaska Native', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Asian', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Native Hawaiian or Other Pacific Islander', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Black or African American', 'measurements': [{'value': '1', 'groupId': 'BG000'}]}, {'title': 'White', 'measurements': [{'value': '15', 'groupId': 'BG000'}]}, {'title': 'More than one race', 'measurements': [{'value': '0', 'groupId': 'BG000'}]}, {'title': 'Unknown or Not Reported', 'measurements': [{'value': '1', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Region of Enrollment', 'classes': [{'title': 'United States', 'categories': [{'measurements': [{'value': '17', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}]}}, 'documentSection': {'largeDocumentModule': {'largeDocs': [{'date': '2023-06-08', 'size': 2525036, 'label': 'Study Protocol and Statistical Analysis Plan', 'hasIcf': False, 'hasSap': True, 'filename': 'Prot_SAP_000.pdf', 'typeAbbrev': 'Prot_SAP', 'uploadDate': '2024-06-25T10:15', 'hasProtocol': True}, {'date': '2023-01-25', 'size': 257936, 'label': 'Informed Consent Form', 'hasIcf': True, 'hasSap': False, 'filename': 'ICF_001.pdf', 'typeAbbrev': 'ICF', 'uploadDate': '2024-08-07T14:41', 'hasProtocol': False}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'DIAGNOSTIC', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 17}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2022-10-12', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2024-08', 'completionDateStruct': {'date': '2023-09-13', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2024-09-12', 'studyFirstSubmitDate': '2020-07-28', 'resultsFirstSubmitDate': '2024-08-09', 'studyFirstSubmitQcDate': '2020-07-28', 'lastUpdatePostDateStruct': {'date': '2024-10-08', 'type': 'ACTUAL'}, 'resultsFirstSubmitQcDate': '2024-09-12', 'studyFirstPostDateStruct': {'date': '2020-08-03', 'type': 'ACTUAL'}, 'resultsFirstPostDateStruct': {'date': '2024-10-08', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2023-09-13', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Sensitivity of Stationary Head CT for the Detection of a Hemorrhage', 'timeFrame': 'Upon completion of all study image data collection for all participants [each participant was assessed approximately 1 hour for the duration of the single one-hour visit]', 'description': 'Sensitivity of stationary head CT for the detection of a hemorrhage using a reader study is defined as the ability of readers (radiologists) to use the stationary head CT to predict hemorrhage using conventional head CT as the gold standard. All stationary head CT scans will be reviewed in a standardized reader study at the conclusion of all study imaging.'}, {'measure': 'Specificity of Stationary Head CT for the Detection of a Hemorrhage', 'timeFrame': 'Upon completion of all study image data collection for all participants [each participant was assessed approximately 1 hour for the duration of the single one-hour visit]', 'description': 'Specificity of stationary head CT for the detection of a hemorrhage using a reader study is defined as the ability of readers (radiologists) to use the stationary head CT to distinguish between individuals that do not have a hemorrhage using conventional head CT as the gold standard. All stationary head CT scans will be reviewed in a standardized reader study at the conclusion of all study imaging.'}, {'measure': 'Sensitivity of Stationary Head CT for the Detection of a Fracture', 'timeFrame': 'Upon completion of all study image data collection for all participants [each participant was assessed approximately 1 hour for the duration of the single one-hour visit]', 'description': 'Sensitivity of stationary head CT for the detection of a fracture using a reader study is defined as the ability of readers (radiologists) to use the stationary head CT to predict a fracture using conventional head CT as the gold standard. All stationary head CT scans will be reviewed in a standardized reader study at the conclusion of all study imaging.'}, {'measure': 'Specificity of Stationary Head CT for the Detection of a Fracture', 'timeFrame': 'Upon completion of all study image data collection for all participants [each participant was assessed approximately 1 hour for the duration of the single one-hour visit]', 'description': 'Specificity of stationary head CT for the detection of a fracture using a reader study is defined as the ability of readers (radiologists) to use the stationary head CT to distinguish between individuals that do not have a fracture using conventional head CT as the gold standard. All stationary head CT scans will be reviewed in a standardized reader study at the conclusion of all study imaging.'}]}, 'oversightModule': {'isUsExport': False, 'oversightHasDmc': False, 'isFdaRegulatedDrug': False, 'isUnapprovedDevice': True, 'isFdaRegulatedDevice': True}, 'conditionsModule': {'conditions': ['Head Trauma']}, 'descriptionModule': {'briefSummary': 'Purpose: The purpose of this study is to evaluate stationary head CT (s-HCT) as a diagnostic tool in patients with known head trauma.\n\nParticipants: Participants will be 50 people who have had either a head trauma or a brain bleed and have undergone a head CT in the past 24 hours or who will undergo a CT scan of the head.\n\nProcedures (methods): This investigation will be a single arm, prospective clinical trial. Participants will have one single visit, which will include the s-HCT scan. No follow-up is required. All images will be de-identified before inclusion within a reader study. The investigators will perform a reader study with physician readers comparing the acquired imaging s-HCT images and conventional head CT.', 'detailedDescription': 'This investigation will be a single arm, prospective clinical trial evaluating stationary head CT (s-HCT) as a diagnostic tool in patients with known head trauma. The investigators hypothesize that a stationary head CT (s-HCT) system based on the carbon nanotube linear array x-ray source can provide diagnostic quality head CT images. Patients included in the study will be 50 people who have had either a head trauma or a brain bleed and have undergone a head CT in the past 24 hours or who will undergo a CT scan of the head.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '18 Years', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* 18 years of age or older\n* Medically stable patient with head trauma or known intracranial hemorrhage (subdural or intraparenchymal) or skull fractures\n* Patient has undergone conventional head CT imaging at UNC hospitals within the past 24 hours or will undergo a CT scan of the head\n* Willing and able to provide written informed consent\n\nExclusion Criteria:\n\n* Unable to provide consent\n* Any woman who is pregnant or has reason to believe she is pregnant (the possibility of pregnancy has to be excluded by negative urine β-HCG results, obtained within 24 hours prior to the research scan, or on the basis of patient history, e.g., tubal ligation, hysterectomy or a minimum of 1 year without menses)\n* Breastfeeding'}, 'identificationModule': {'nctId': 'NCT04495634', 'briefTitle': 'Evaluation of a Carbon Nanotube Enabled Solid-State Head CT', 'organization': {'class': 'OTHER', 'fullName': 'University of North Carolina, Chapel Hill'}, 'officialTitle': 'Evaluation of a Carbon Nanotube Enabled Solid-State Head CT', 'orgStudyIdInfo': {'id': '20-0614'}, 'secondaryIdInfos': [{'id': 'W81XWH1820043', 'type': 'OTHER_GRANT', 'domain': 'United States Department of Defense'}]}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Head Trauma or Brain Bleed', 'description': 'Medically stable patients who have undergone conventional head CT imaging undergo imaging within 24 hours using the s-HCT system.', 'interventionNames': ['Device: Stationary Head CT (s-HCT)']}], 'interventions': [{'name': 'Stationary Head CT (s-HCT)', 'type': 'DEVICE', 'description': 'The system consists of a total of three x-ray sources and nine x-ray detectors with an estimation of approximately 150 projection angles per slice, with less than a minute per slice reconstruction. Radiation dose will be configured as to not exceed that of a conventional head CT, or 2 mSv. The subjects will be positioned on a medical procedure table that will move the subject through the scanning system at the rate of roughly 1 cm per second, during which the necessary x-ray projections will be acquired. The head will be positioned in a carbon fiber head holder from a clinical CT scanner that is secured to the table.', 'armGroupLabels': ['Head Trauma or Brain Bleed']}]}, 'contactsLocationsModule': {'locations': [{'zip': '27599', 'city': 'Chapel Hill', 'state': 'North Carolina', 'country': 'United States', 'facility': 'UNC Hospitals', 'geoPoint': {'lat': 35.9132, 'lon': -79.05584}}], 'overallOfficials': [{'name': 'Carlos Zamora, MD, PhD', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'University of North Carolina, Chapel Hill'}]}, 'ipdSharingStatementModule': {'timeFrame': '9 to 36 months following publication', 'ipdSharing': 'YES', 'description': 'Deidentified individual data that supports the results will be shared beginning 9 to 36 months following publication provided the investigator who proposes to use the data has approval from an Institutional Review Board (IRB), Independent Ethics Committee (IEC), or Research Ethics Board (REB), as applicable, and executes a data use/sharing agreement with UNC.', 'accessCriteria': 'The investigator who proposes to use the data has approval from an IRB, IEC, or REB, as applicable, and an executed data use/sharing agreement with UNC.'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'University of North Carolina, Chapel Hill', 'class': 'OTHER'}, 'collaborators': [{'name': 'United States Department of Defense', 'class': 'FED'}], 'responsibleParty': {'type': 'SPONSOR'}}}}