Raw JSON
{'hasResults': True, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24', 'submissionTracking': {'firstMcpInfo': {'postDateStruct': {'date': '2021-04-08', 'type': 'ACTUAL'}}}}, 'conditionBrowseModule': {'meshes': [{'id': 'D006319', 'term': 'Hearing Loss, Sensorineural'}], 'ancestors': [{'id': 'D034381', 'term': 'Hearing Loss'}, {'id': 'D006311', 'term': 'Hearing Disorders'}, {'id': 'D004427', 'term': 'Ear Diseases'}, {'id': 'D010038', 'term': 'Otorhinolaryngologic Diseases'}, {'id': 'D012678', 'term': 'Sensation Disorders'}, {'id': 'D009461', 'term': 'Neurologic Manifestations'}, {'id': 'D009422', 'term': 'Nervous System Diseases'}, {'id': 'D012816', 'term': 'Signs and Symptoms'}, {'id': 'D013568', 'term': 'Pathological Conditions, Signs and Symptoms'}]}}, 'resultsSection': {'moreInfoModule': {'pointOfContact': {'email': 'kendra.marks@northwestern.edu', 'phone': '847-467-0897', 'title': 'Kendra Marks', 'organization': 'Northwestern University'}, 'certainAgreement': {'piSponsorEmployee': False, 'restrictiveAgreement': False}}, 'adverseEventsModule': {'timeFrame': '5 months', 'eventGroups': [{'id': 'EG000', 'title': 'Experiences Hearing Aid User', 'description': 'Single arm study, all participants in this arm. Participants will be experienced hearing aid users.\n\nRemote Microphone: Experienced hearing aid users will be trained on and use a remote microphone for 30 days. Pre- and Post- measures will be taken to determine benefit. Participant characteristics will also be assessed (such as self-efficacy) to explore personality factors that may contribute to benefit from devices.', 'otherNumAtRisk': 22, 'deathsNumAtRisk': 22, 'otherNumAffected': 0, 'seriousNumAtRisk': 22, 'deathsNumAffected': 0, 'seriousNumAffected': 0}], 'frequencyThreshold': '0'}, 'outcomeMeasuresModule': {'outcomeMeasures': [{'type': 'PRIMARY', 'title': 'Change in Abbreviated Profile of Hearing Aid Benefit (APHAB)', 'denoms': [{'units': 'Participants', 'counts': [{'value': '17', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Experienced Hearing Aid User', 'description': 'Single arm study, all participants in this arm. Participants will be experienced hearing aid users.\n\nRemote Microphone: Experienced hearing aid users will be trained on and use a remote microphone for 30 days. Pre- and Post- measures will be taken to determine benefit. Participant characteristics will also be assessed (such as self-efficacy) to explore personality factors that may contribute to benefit from devices.'}], 'classes': [{'title': 'Overall APHAB Change', 'categories': [{'measurements': [{'value': '7.64', 'groupId': 'OG000', 'lowerLimit': '-11.7', 'upperLimit': '24.8'}]}]}, {'title': 'Change in BN', 'categories': [{'measurements': [{'value': '12.5', 'groupId': 'OG000', 'lowerLimit': '-5.8', 'upperLimit': '35.1'}]}]}, {'title': 'Change in RV', 'categories': [{'measurements': [{'value': '4.8', 'groupId': 'OG000', 'lowerLimit': '-22.8', 'upperLimit': '37.7'}]}]}, {'title': 'Change in EC', 'categories': [{'measurements': [{'value': '6.3', 'groupId': 'OG000', 'lowerLimit': '-1.5', 'upperLimit': '23.7'}]}]}, {'title': 'Change in AV', 'categories': [{'measurements': [{'value': '-2.6', 'groupId': 'OG000', 'lowerLimit': '-70.3', 'upperLimit': '35.2'}]}]}], 'paramType': 'MEAN', 'timeFrame': 'Change from baseline to final appointment will be assessed. Participants will take a baseline at the start of the trial and then complete post-intervention at the end of the 30-day trial.', 'description': 'Self assessment, disability based inventory that is used to document outcomes of hearing aid fittings. The APHAB uses a percentile scale (Percent of Problems). This measure has 4 subscales: Ease of communication (EC), Reverberation (RV), Background Noise (BN), and Aversiveness (AV). A lower score indicates a better outcome. We will look at both the global change (defined as EC, RV, and BN scores improving by at least 5 points each) and individual subscales (For EC, RV, or BN a change in 22 points is considered significant and for AV a change of 31 points is needed to be considered significant).', 'unitOfMeasure': '% of Problems (Change from baseline)', 'dispersionType': 'Full Range', 'reportingStatus': 'POSTED', 'populationDescription': 'Participants who did not complete their study participation prior to the start of Covid shutdown are excluded, as their opportunity for social activity and listening environments drastically changed from their baseline measurements.'}, {'type': 'SECONDARY', 'title': 'Change in Speech, Spatial, and Qualities of Hearing (SSQ)', 'denoms': [{'units': 'Participants', 'counts': [{'value': '17', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Experienced Hearing Aid User', 'description': 'Single arm study, all participants in this arm. Participants will be experienced hearing aid users.\n\nRemote Microphone: Experienced hearing aid users will be trained on and use a remote microphone for 30 days. Pre- and Post- measures will be taken to determine benefit. Participant characteristics will also be assessed (such as self-efficacy) to explore personality factors that may contribute to benefit from devices.'}], 'classes': [{'title': 'Speech', 'categories': [{'measurements': [{'value': '1.7', 'groupId': 'OG000', 'lowerLimit': '0', 'upperLimit': '3.6'}]}]}, {'title': 'Spatial', 'categories': [{'measurements': [{'value': '0.6', 'groupId': 'OG000', 'lowerLimit': '-0.9', 'upperLimit': '5.1'}]}]}, {'title': 'Quality', 'categories': [{'measurements': [{'value': '1.1', 'groupId': 'OG000', 'lowerLimit': '-1.2', 'upperLimit': '4.9'}]}]}], 'paramType': 'MEAN', 'timeFrame': 'Change from baseline to final appointment will be assessed. Participants will take a baseline at the start of the trial and then complete post-intervention at the end of the 30-day trial.', 'description': 'Questionnaire, clinical patient interview design where participants respond on a scale of 0 to 10, with 10 indicating perfect hearing ability and 0 indicating complete inability.There are 3 subscales calculated by averaged the responses to the questions for each subscale. A change of 2 points is considered a moderate effect with increase in score indicating improvement.', 'unitOfMeasure': 'score on a scale', 'dispersionType': 'Full Range', 'reportingStatus': 'POSTED'}, {'type': 'SECONDARY', 'title': '% of Words Repeated Correctly in a Sentence Recognition Task With Variable Levels of Background Noise', 'denoms': [{'units': 'Participants', 'counts': [{'value': '17', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Experienced Hearing Aid User', 'description': 'Single arm study, all participants in this arm. Participants will be experienced hearing aid users.\n\nRemote Microphone: Experienced hearing aid users will be trained on and use a remote microphone for 30 days. Pre- and Post- measures will be taken to determine benefit. Participant characteristics will also be assessed (such as self-efficacy) to explore personality factors that may contribute to benefit from devices.'}], 'classes': [{'title': 'Hearing Aid Only', 'categories': [{'measurements': [{'value': '60.0', 'groupId': 'OG000', 'lowerLimit': '0', 'upperLimit': '100'}]}]}, {'title': 'Hearing aid + Remote Mic', 'categories': [{'measurements': [{'value': '82.7', 'groupId': 'OG000', 'lowerLimit': '0', 'upperLimit': '100.00'}]}]}], 'paramType': 'MEAN', 'timeFrame': 'End of trial: Objective speech intel was collected in one session at the end of the 30 day trial with the remote microphone. Order of conditions (Hearing aid only and Hearing Aid+ Remote Mic) was randomized.', 'description': 'Participants had to repeat sentences presented to them in varying levels of background noise. Sentences are scores based on the number of key words (5) they get correct.', 'unitOfMeasure': '% Correct', 'dispersionType': 'Full Range', 'reportingStatus': 'POSTED', 'populationDescription': 'Participants who did not complete their study participation prior to the start of Covid shutdown are excluded, as their opportunity for social activity and listening environments drastically changed from their baseline measurements.'}]}, 'participantFlowModule': {'groups': [{'id': 'FG000', 'title': 'Experienced Hearing Aid User', 'description': 'Single arm study, all participants in this arm. Participants will be experienced hearing aid users.\n\nRemote Microphone: Experienced hearing aid users will be trained on and use a remote microphone for 30 days. Pre- and Post- measures will be taken to determine benefit. Participant characteristics will also be assessed (such as self-efficacy) to explore personality factors that may contribute to benefit from devices.'}], 'periods': [{'title': 'Overall Study', 'milestones': [{'type': 'STARTED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '22'}]}, {'type': 'COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '22'}]}, {'type': 'NOT COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '0'}]}]}]}, 'baselineCharacteristicsModule': {'denoms': [{'units': 'Participants', 'counts': [{'value': '22', 'groupId': 'BG000'}]}], 'groups': [{'id': 'BG000', 'title': 'Experienced Hearing Aid User', 'description': 'Single arm study, all participants in this arm. Participants will be experienced hearing aid users.\n\nRemote Microphone: Experienced hearing aid users will be trained on and use a remote microphone for 30 days. Pre- and Post- measures will be taken to determine benefit. Participant characteristics will also be assessed (such as self-efficacy) to explore personality factors that may contribute to benefit from devices.'}], 'measures': [{'title': 'Age, Continuous', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '22', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '75.5', 'groupId': 'BG000', 'lowerLimit': '59', 'upperLimit': '88'}]}]}], 'paramType': 'MEAN', 'unitOfMeasure': 'years', 'dispersionType': 'FULL_RANGE'}, {'title': 'Sex: Female, Male', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '22', 'groupId': 'BG000'}]}], 'categories': [{'title': 'Female', 'measurements': [{'value': '10', 'groupId': 'BG000'}]}, {'title': 'Male', 'measurements': [{'value': '12', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Race and Ethnicity Not Collected', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '0', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants', 'populationDescription': 'Race and Ethnicity were not collected from any participant.'}, {'title': 'Abbreviated Profile of Hearing Aid Benefit (APHAB)', 'classes': [{'title': 'APHAB: Overall Baseline', 'denoms': [{'units': 'Participants', 'counts': [{'value': '17', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '28.9', 'groupId': 'BG000', 'lowerLimit': '10.1', 'upperLimit': '47.0'}]}]}, {'title': 'APHAB Background Noise Baseline', 'denoms': [{'units': 'Participants', 'counts': [{'value': '22', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '37.0', 'groupId': 'BG000', 'lowerLimit': '10.5', 'upperLimit': '64.3'}]}]}, {'title': 'APHAB Aversiveness Baseline', 'denoms': [{'units': 'Participants', 'counts': [{'value': '22', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '39.7', 'groupId': 'BG000', 'lowerLimit': '1.0', 'upperLimit': '85.00'}]}]}, {'title': 'APHAB Ease of Communication Baseline', 'denoms': [{'units': 'Participants', 'counts': [{'value': '22', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '20.15', 'groupId': 'BG000', 'lowerLimit': '2.8', 'upperLimit': '49.8'}]}]}, {'title': 'APHAB Reverberation Baseline', 'denoms': [{'units': 'Participants', 'counts': [{'value': '22', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '30.4', 'groupId': 'BG000', 'lowerLimit': '4.7', 'upperLimit': '66.5'}]}]}], 'paramType': 'MEAN', 'description': 'The APHAB is a questionnaire administered before and after intervention asking a lister to rate how much difficulty they have in different listening scenarios. An overall and 4 subscores (Background noise, Ease of Communications, Aversiveness, and Reverberation) are then calculated based on the responses.', 'unitOfMeasure': '% of problems', 'dispersionType': 'FULL_RANGE', 'populationDescription': 'Participants who did not complete their study participation prior to the start of Covid shutdown are excluded, as their opportunity for social activity and listening environments drastically changed from their baseline measurements.'}, {'title': '% of words repeated correctly in a sentence recog. task with variable levels of background noise: HA', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '17', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '61.0', 'spread': '35.6', 'groupId': 'BG000'}]}]}], 'paramType': 'MEAN', 'description': 'Participants listened to a series of sentences presented in variable background noise. They repeated each sentence to the best of their abilities. They are scored based on the number of key words (5 in each sentence) they get correct.', 'unitOfMeasure': '% Correct', 'dispersionType': 'STANDARD_DEVIATION', 'populationDescription': 'Participants who did not complete their study participation prior to the start of Covid shutdown are excluded, and their opportunity for social activity and listening environments drastically changed from their baseline measurements.'}]}}, 'documentSection': {'largeDocumentModule': {'noSap': True, 'largeDocs': [{'date': '2020-02-14', 'size': 382271, 'label': 'Study Protocol', 'hasIcf': False, 'hasSap': False, 'filename': 'Prot_001.pdf', 'typeAbbrev': 'Prot', 'uploadDate': '2021-04-07T13:53', 'hasProtocol': True}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'TREATMENT', 'interventionModel': 'SINGLE_GROUP', 'interventionModelDescription': 'Within-subject design: Baseline assessments compared to post-trial results.'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 22}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2019-08-30', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2021-05', 'completionDateStruct': {'date': '2020-04-15', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2021-05-30', 'studyFirstSubmitDate': '2019-03-20', 'resultsFirstSubmitDate': '2021-03-14', 'studyFirstSubmitQcDate': '2019-03-28', 'lastUpdatePostDateStruct': {'date': '2021-06-10', 'type': 'ACTUAL'}, 'resultsFirstSubmitQcDate': '2021-05-05', 'studyFirstPostDateStruct': {'date': '2019-04-01', 'type': 'ACTUAL'}, 'resultsFirstPostDateStruct': {'date': '2021-05-28', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2020-03-15', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Change in Abbreviated Profile of Hearing Aid Benefit (APHAB)', 'timeFrame': 'Change from baseline to final appointment will be assessed. Participants will take a baseline at the start of the trial and then complete post-intervention at the end of the 30-day trial.', 'description': 'Self assessment, disability based inventory that is used to document outcomes of hearing aid fittings. The APHAB uses a percentile scale (Percent of Problems). This measure has 4 subscales: Ease of communication (EC), Reverberation (RV), Background Noise (BN), and Aversiveness (AV). A lower score indicates a better outcome. We will look at both the global change (defined as EC, RV, and BN scores improving by at least 5 points each) and individual subscales (For EC, RV, or BN a change in 22 points is considered significant and for AV a change of 31 points is needed to be considered significant).'}], 'secondaryOutcomes': [{'measure': 'Change in Speech, Spatial, and Qualities of Hearing (SSQ)', 'timeFrame': 'Change from baseline to final appointment will be assessed. Participants will take a baseline at the start of the trial and then complete post-intervention at the end of the 30-day trial.', 'description': 'Questionnaire, clinical patient interview design where participants respond on a scale of 0 to 10, with 10 indicating perfect hearing ability and 0 indicating complete inability.There are 3 subscales calculated by averaged the responses to the questions for each subscale. A change of 2 points is considered a moderate effect with increase in score indicating improvement.'}, {'measure': '% of Words Repeated Correctly in a Sentence Recognition Task With Variable Levels of Background Noise', 'timeFrame': 'End of trial: Objective speech intel was collected in one session at the end of the 30 day trial with the remote microphone. Order of conditions (Hearing aid only and Hearing Aid+ Remote Mic) was randomized.', 'description': 'Participants had to repeat sentences presented to them in varying levels of background noise. Sentences are scores based on the number of key words (5) they get correct.'}]}, 'oversightModule': {'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': True}, 'conditionsModule': {'keywords': ['Assistive Listening Device (ALD)', 'Hearing in Noise'], 'conditions': ['Hearing Loss, Sensorineural']}, 'descriptionModule': {'briefSummary': 'Despite improvements in digital hearing aid technology, many hearing aid users continue to report difficulty understanding speech in challenging listening environments. Remote microphones have been shown to provide benefit in the most common of these challenging listening environments: distant speakers, background noise, and reverberation. Despite demonstrated benefit, there is a low rate of remote microphone use among adult hearing aid users. One reason for low uptake may be an uncertainty among hearing healthcare providers and potential users regarding expected clinically relevant benefit. This clinical trial will attempt the following:\n\n1. To describe the range of remote microphone benefit among adults with mild-to-moderate sensorineural hearing loss\n2. To determine specific individual factors beyond the audiogram that are associated with greater benefit from remote microphones', 'detailedDescription': "2.0 Background / Literature Review / Rationale for the study:\n\nEven when wearing well-fit hearing aids, many individuals with hearing loss continue to report difficulty communicating in background noise is one of the most common complaints of individuals with hearing loss. Directional microphones can improve speech perception in noise, but often fail to provide benefit in cases where the talker is distant from the listener, where there are multiple or moving noise sources, or in reverberation. Digital noise reduction may reduce listening effort and improve listening comfort, but has minimal effect on speech perception.\n\nPlacing the microphone in close proximity to the talker reduces the effective distance between speaker and listener, compensating for the effects of background noise and reverberation on the target signal. Use of a remote microphone can significantly improve signal-to-noise ratio (SNR), thereby improving speech perception in noise and at a distance. Recent studies demonstrated that remote-microphone devices that utilize adaptive digital technology (i.e, Roger) provide significantly more benefit for speech understanding in noise than non-adaptive remote microphones. Those advantages are likely related to the adaptive nature of the device, whereby the microphone gain varies according to the level of noise in the environment. In addition, interference is reduced via transmission of short digital bursts (160 μs) across a range of channels (2.4-2.4835 GHz). Further, the ability to utilize the hearing aids' onboard directional microphones in conjunction with a remote microphone gives listeners the benefits of remote microphone use without sacrificing nearfield intelligibility. The Roger system has also been shown to improve cell phone communication amongst cochlear implant patients.\n\nDespite demonstrated advantages, use of remote microphone assistive devices among adults is low. In a recent study of listeners with severe hearing loss-a group which has substantial difficulty communicating in background noise, and is likely to receive significant benefits from remote-microphone devices-less than 10% reported use of a remote microphone. While cost may be a barrier for some users, even when such systems are available for free (as in the Veterans Administration), use is still low. One reason may be uncertainty among both providers and potential users as to expected benefit for a given listener. For example, Lewis et al. failed to demonstrate a clinically-significant benefit of remote microphone use using a work-life outcomes scale in a cohort of mostly nonworking (retired) participants. Wolfe et al. found significant improvements in objective speech recognition on average, but with a wide range of benefit (from 10% to 60% improvement across individual participants). That study also suggested that individual factors may affect remote microphone benefit, in that the magnitude of improved recognition was correlated with the ability to use spatial cues to improve recognition.\n\nResearch Locations:\n\nAll study tasks will take place in the Hearing Aid Lab and/or Northwestern's Center for Audiology, Speech, Language and Learning.\n\nWhen testing in the Hearing Aid Lab, Frances Searle building room 1-451, we will either use the sound booth or lab space. All hearing related tasks take place in a sound booth which is a sound treated 8'x 8' room within the larger lab space. When taking histories or cognitive measures we will use the office space located within the lab or an additional nearby (i.e. same building) testing room. The additional test room is only used if participant confidentiality can be maintained (i.e. conversation is not audible to those outside the room). When using the Center for Audiology, Speech, Language and Learning all tasks will take place in a sound proof booth, in a clinical Hearing Aid fit room, or the virtual sound environment (ViSoR). ViSoR is a 16' by 14' by 9' space capable of simulating the acoustics and background noise properties of any environment by using an array of speakers.\n\nApproach\n\nThe trial will use a within-subjects design consisting of baseline assessment (see assessments), hearing aid with Roger connect fitting, a four week trial period of use in the participant's everyday environment(s), and outcome measures.\n\nParticipants who qualify for a dome fitting will start their trial the same day as their baseline assessment. Participants who require a custom mold fitting will have earmold impressions taken at their baseline assessment and then be fit with the trial devices after the custom earmold has arrived back in the lab, usually about one week later. During an earmold impression the ear is visually inspected with an otoscope (magnifying scope with light). A cotton block and soft material are placed in the ear. The resulting impression created by the soft material is used to order an earmold for later testing. This is a standard clinical procedure.\n\nA licensed clinical audiologist will perform the assessments, fitting and counseling of hearing aids and Roger system, and conduct the outcome measures. To ensure appropriate fit and use by the participants, there will be a follow-up one week after being fit with the devices. During this appointment participants will be evaluated and their hearing aid logging will be checked for compliance.\n\nHearing aid/Roger fitting: Trial hearing aids and clinically-appropriate earmolds or domes will be provided by Phonak at no charge to the participants for the duration of the trial. Those aids are expected to be drawn from Phonak's advanced technology level and to provide datalogging via 7 base programs. Aids will be set to NAL-NL2 targets using probe microphone measurements. Directional microphones will be enabled and verified via probe-microphone testing. Roger will be verified via probe-microphone testing, following clinical best practice. Appropriate hearing aid adjustments (as judged by the study audiologist) will be permitted to provide acceptable sound quality and loudness. Final REARs will be recorded. The study audiologist will instruct participants regarding hearing aid and Roger device use. PHAST-R and a Roger competency questionnaire (to be developed with input from Phonak) will be used to document understanding of device function at the fitting and one week follow-up appointments. Participants will then wear the hearing aids and use the Roger system for 1 month in their everyday listening environments. At the completion of the trial, participants will return to the lab for outcome assessments and to provide spontaneous feedback regarding their experiences. Hearing aids and remote microphone will be returned to the study site following completion of the trial."}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'maximumAge': '85 Years', 'minimumAge': '18 Years', 'healthyVolunteers': True, 'eligibilityCriteria': 'Inclusion Criteria:\n\n1. Adults age 18-85 years\n2. Speak English as their primary language\n3. Normal or corrected to normal vision\n4. Sensorineural hearing loss with pure-tone thresholds 20-85 dB HL at octave frequencies between 500 and 3000 Hz\n5. Current hearing aid wearer with at least 3 months of experience\n\nExclusion Criteria:\n\n1. Clinically significant unstable or progressive medical conditions, or conditions which, in the opinion of the investigator places the participant at unacceptable risk if he or she were to participate in the study\n2. Participants who do not pass a cognitive screening test (e.g., MoCA)\n3. Significant history of otologic or neurologic disorders\n4. Conductive hearing loss pathology or fluctuating hearing loss'}, 'identificationModule': {'nctId': 'NCT03897634', 'briefTitle': 'Remote Microphone Candidacy Study', 'organization': {'class': 'OTHER', 'fullName': 'Northwestern University'}, 'officialTitle': 'Clinical Trial of Roger Adaptive Digital Technology', 'orgStudyIdInfo': {'id': 'SP0053453'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Experiences Hearing Aid user', 'description': 'Single arm study, all participants in this arm. Participants will be experienced hearing aid users.', 'interventionNames': ['Device: Remote Microphone']}], 'interventions': [{'name': 'Remote Microphone', 'type': 'DEVICE', 'otherNames': ['Roger Select'], 'description': 'Experienced hearing aid users will be trained on and use a remote microphone for 30 days. Pre- and Post- measures will be taken to determine benefit. Participant characteristics will also be assessed (such as self-efficacy) to explore personality factors that may contribute to benefit from devices.', 'armGroupLabels': ['Experiences Hearing Aid user']}]}, 'contactsLocationsModule': {'locations': [{'zip': '60208', 'city': 'Evanston', 'state': 'Illinois', 'country': 'United States', 'facility': 'Northwestern University', 'geoPoint': {'lat': 42.04114, 'lon': -87.69006}}], 'overallOfficials': [{'name': 'Pamela Souza, PhD', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Northwestern University'}]}, 'ipdSharingStatementModule': {'ipdSharing': 'NO'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Northwestern University', 'class': 'OTHER'}, 'collaborators': [{'name': 'Phonak AG, Switzerland', 'class': 'INDUSTRY'}], 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'Professor', 'investigatorFullName': 'Pamela Souza', 'investigatorAffiliation': 'Northwestern University'}}}}