Viewing Study NCT02458534


Ignite Creation Date: 2025-12-25 @ 2:18 AM
Ignite Modification Date: 2026-02-21 @ 6:24 AM
Study NCT ID: NCT02458534
Status: COMPLETED
Last Update Posted: 2015-08-19
First Post: 2015-05-26
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: The Comparison of Mcgrath Mac, C-MAC, and Macintosh Laryngoscope in Novice Users: a Manikin Study
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'RANDOMIZED', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'TREATMENT', 'interventionModel': 'CROSSOVER'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 39}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2015-05'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2015-08', 'completionDateStruct': {'date': '2015-07', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2015-08-18', 'studyFirstSubmitDate': '2015-05-26', 'studyFirstSubmitQcDate': '2015-05-27', 'lastUpdatePostDateStruct': {'date': '2015-08-19', 'type': 'ESTIMATED'}, 'studyFirstPostDateStruct': {'date': '2015-06-01', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2015-07', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'time to intubation', 'timeFrame': 'within 3 minutes after the insertion of the laryngoscope into the mouth of the manikin', 'description': 'Time to intubation is defined as the time from the insertion of the laryngoscope into the mouth of the manikin to the confirmation of the chest movement of the manikin.'}], 'secondaryOutcomes': [{'measure': 'success rate of the first intubation attempt', 'timeFrame': 'Within 3 minutes after the insertion of the laryngoscope into the mouth of the manikin'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'keywords': ['Simulated manikin'], 'conditions': ['Healthy']}, 'descriptionModule': {'briefSummary': 'The purpose of this study is to evaluate whether the McGrath MAC videolaryngoscope is superior when compared to the C-MAC videolaryngoscope and the Macintosh laryngoscope for novice users in manikin.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT'], 'maximumAge': '40 Years', 'minimumAge': '20 Years', 'healthyVolunteers': True, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Medical students\n\nExclusion Criteria:\n\n* wrist disease excluded.'}, 'identificationModule': {'nctId': 'NCT02458534', 'briefTitle': 'The Comparison of Mcgrath Mac, C-MAC, and Macintosh Laryngoscope in Novice Users: a Manikin Study', 'organization': {'class': 'OTHER', 'fullName': 'Yonsei University'}, 'orgStudyIdInfo': {'id': '1-2015-0020'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Mcgrath Mac videolaryngoscope', 'description': 'Participants perform three intubation attempts using Mcgrath Mac videolaryngoscope in the manikin with the normal airway setting. Then the participants perform three intubation attempts using the manikin with difficult airway setting.', 'interventionNames': ['Other: Mcgrath Mac videolaryngoscope']}, {'type': 'EXPERIMENTAL', 'label': 'C-MAC videolaryngoscope', 'description': 'Participants perform three intubation attempts using C-MAC videolaryngoscope in the manikin with the normal airway setting. Then the participants perform three intubation attempts using the manikin with difficult airway setting.', 'interventionNames': ['Other: C-MAC videolaryngoscope']}, {'type': 'ACTIVE_COMPARATOR', 'label': 'Macintosh laryngoscope', 'description': 'Participants perform three intubation attempts using macintosh laryngoscope in the manikin with the normal airway setting. Then the participants perform three intubation attempts using the manikin with difficult airway setting.', 'interventionNames': ['Other: macintosh laryngoscope']}], 'interventions': [{'name': 'Mcgrath Mac videolaryngoscope', 'type': 'OTHER', 'description': 'Participants perform three intubation attempts using Mcgrath Mac videolaryngoscope in the manikin with the normal airway and difficult airway settings.', 'armGroupLabels': ['Mcgrath Mac videolaryngoscope']}, {'name': 'C-MAC videolaryngoscope', 'type': 'OTHER', 'description': 'Participants perform three intubation attempts using C-MAC videolaryngoscope in the manikin with the normal airway and difficult airway settings.', 'armGroupLabels': ['C-MAC videolaryngoscope']}, {'name': 'macintosh laryngoscope', 'type': 'OTHER', 'description': 'Participants perform three intubation attempts using macintosh laryngoscope in the manikin with the normal airway and difficult airway settings.', 'armGroupLabels': ['Macintosh laryngoscope']}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Yonsei University', 'class': 'OTHER'}, 'responsibleParty': {'type': 'SPONSOR'}}}}