Viewing Study NCT04313595


Ignite Creation Date: 2025-12-24 @ 2:20 PM
Ignite Modification Date: 2025-12-26 @ 11:59 PM
Study NCT ID: NCT04313595
Status: COMPLETED
Last Update Posted: 2020-03-18
First Post: 2020-02-26
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Device for Breathing Frequency Monitoring in Muscular Dystrophy
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D009136', 'term': 'Muscular Dystrophies'}], 'ancestors': [{'id': 'D020966', 'term': 'Muscular Disorders, Atrophic'}, {'id': 'D009135', 'term': 'Muscular Diseases'}, {'id': 'D009140', 'term': 'Musculoskeletal Diseases'}, {'id': 'D009468', 'term': 'Neuromuscular Diseases'}, {'id': 'D009422', 'term': 'Nervous System Diseases'}, {'id': 'D030342', 'term': 'Genetic Diseases, Inborn'}, {'id': 'D009358', 'term': 'Congenital, Hereditary, and Neonatal Diseases and Abnormalities'}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'SUPPORTIVE_CARE', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 15}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2018-07-29', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2020-03', 'completionDateStruct': {'date': '2019-07-15', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2020-03-17', 'studyFirstSubmitDate': '2020-02-26', 'studyFirstSubmitQcDate': '2020-03-17', 'lastUpdatePostDateStruct': {'date': '2020-03-18', 'type': 'ACTUAL'}, 'studyFirstPostDateStruct': {'date': '2020-03-18', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2019-07-15', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Safety of the device', 'timeFrame': 'After 24 hours of continued use', 'description': 'Recording of any adverse events'}, {'measure': 'Usability of the device (System Usability Scale)', 'timeFrame': 'After 24 hours of continued use', 'description': 'System Usability Scale (SUS acceptance and wearability of the device):the scores range from 0 to 100 in 2.5-point increments, with higher values meaning high perceived usability of the system'}, {'measure': 'Acceptability of the device (Technological Acceptance Measure)', 'timeFrame': 'After 24 hours of continued use', 'description': 'Technological Acceptance Measure (TAM) questionnaire appropriate for the medical device: with higher values meaning high acceptance of the system'}], 'secondaryOutcomes': [{'measure': 'Accuracy in measuring the breathing frequency', 'timeFrame': 'Immediately after application of the device', 'description': 'Comparison between the measures of respiratory rate by using the device and by using already validated instrumentation: Optoelectronic Plethysmography (OEP), optoelectronic movement analysis system.\n\nChest wall movements during breathing are simultaneously recorded by the RespirHó device and by Optoelectronic Plethysmography (OEP), in static conditions, and in particular, in supine and seated positions.\n\nOEP allows assessment of ventilatory and breathing pattern by measuring chest-wall movements related to breathing, by using motion capture principles.\n\nUsing OEP as reference method it is possible to compare the data recorded with the thoracic and abdominal units of the device RespirHó with those obtained by using OEP for the thoracic and abdominal compartments'}]}, 'oversightModule': {'oversightHasDmc': False, 'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': False}, 'conditionsModule': {'conditions': ['Muscular Dystrophies']}, 'descriptionModule': {'briefSummary': 'Patients at risk of developing respiratory dysfunctions, such as patients with severe forms of muscular dystrophy, need a careful respiratory assessment, and periodic follow-up visits to monitor the progression of the disease. Continuous monitoring of respiratory activity pattern at home could give additional understandings about disease progression, flanking traditional, intermittent, cardiopulmonary evaluations, allowing prompt clinical intervention, and anticipating respiratory dysfunction. The main objective of the present study is thus to investigate the feasibility of using an innovative wearable device for respiratory monitoring, especially breathing frequency variation assessment, in patients with muscular dystrophy. The comparison between the measurements of breathing frequency obtained by using the IMU-based device and by using the reference method provided optimal results, in terms of accuracy errors, correlation and agreement. Participants positively evaluated the device for what concerns ease of use, comfort, usability and wearability. Moreover, preliminary results confirmed that breathing frequency is an interesting breathing parameter to monitor, at the clinic and at home, because it strongly correlates with the main indexes of respiratory function'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['CHILD', 'ADULT', 'OLDER_ADULT'], 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion criteria:\n\n* documented DMD or LGMD2\n* loss of independent ambulation (wheelchair-bound patients)\n* ability to understand and follow test instructions and to report pain and discomfort.\n\nExclusion criteria:\n\n* presence of metal implants and cardiac pacemakers\n* relevant concomitant comorbidities (e.g.epilepsy)\n* behaviour and/or psychiatric disorders (e.g. emotional problems, anxiety, panic attacks).'}, 'identificationModule': {'nctId': 'NCT04313595', 'briefTitle': 'Device for Breathing Frequency Monitoring in Muscular Dystrophy', 'organization': {'class': 'OTHER', 'fullName': 'IRCCS Eugenio Medea'}, 'officialTitle': 'A Wearable Device for Breathing Frequency Monitoring: a Pilot Study on Patients With Muscular Dystrophy', 'orgStudyIdInfo': {'id': '534'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Breathing frequency monitoring', 'interventionNames': ['Device: RespirHó']}], 'interventions': [{'name': 'RespirHó', 'type': 'DEVICE', 'description': 'The system is a wearable, unobtrusive inertial-sensor-based device for long-term breathing pattern monitoring, also during daily life activities. It consists of three IMU-sensor units (3-axis accelerometer, 3-axis gyroscope, 3-axis magnetometer), positioned respectively on the patient\'s abdomen and thorax, and on a body area integral with thorax but not affected by espiratory movements. The peripheral units, placed on thorax and abdomen are used to record orientation changes during respiratory movements. The third unit is a central reference unit (hereafter CRU) that receives data from the other two units, save them on an SD card and communicate via Bluetooth with a smartphone / tablet / PC. Moreover, this unit detects only non-respiratory movement, representing not only a pure source of "noise" that must be removed from the thoracic and bdominal signals, but also a pure source of additional information regarding the state of ctivity of the subject .', 'armGroupLabels': ['Breathing frequency monitoring']}]}, 'contactsLocationsModule': {'locations': [{'zip': '23842', 'city': 'Bosisio Parini', 'state': 'Lecco', 'country': 'Italy', 'facility': 'IRCCS Medea', 'geoPoint': {'lat': 45.80075, 'lon': 9.29}}]}, 'ipdSharingStatementModule': {'ipdSharing': 'NO'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'IRCCS Eugenio Medea', 'class': 'OTHER'}, 'responsibleParty': {'type': 'SPONSOR'}}}}