Viewing Study NCT02392260


Ignite Creation Date: 2025-12-25 @ 2:08 AM
Ignite Modification Date: 2026-02-24 @ 5:45 AM
Study NCT ID: NCT02392260
Status: UNKNOWN
Last Update Posted: 2015-03-18
First Post: 2015-03-12
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Non-invasive Screening of the Status of the Vascular System: Feasibility Test
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ESTIMATED', 'count': 50}}, 'statusModule': {'overallStatus': 'UNKNOWN', 'lastKnownStatus': 'NOT_YET_RECRUITING', 'startDateStruct': {'date': '2015-04'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2015-03', 'completionDateStruct': {'date': '2015-04', 'type': 'ESTIMATED'}, 'lastUpdateSubmitDate': '2015-03-17', 'studyFirstSubmitDate': '2015-03-12', 'studyFirstSubmitQcDate': '2015-03-17', 'lastUpdatePostDateStruct': {'date': '2015-03-18', 'type': 'ESTIMATED'}, 'studyFirstPostDateStruct': {'date': '2015-03-18', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2015-04', 'type': 'ESTIMATED'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Pulse Wave velocity', 'timeFrame': '1 month', 'description': 'Bland Altmann test and ROC analysis will be used to compare the 2 methods'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'conditions': ['To Evaluate the Validity of the Measure Method, we Will Compare Vasculight v1.0 PWV Measures With Those Obtained From E-tracking (Echocardiographic Method).']}, 'descriptionModule': {'briefSummary': 'This project is part of the EU funded project NISTAS. NISTAS aims at the development of a new medical device for non-contact, non-invasive screening of the health status of the vascular system of adult subjects. The instrument, called VascuLight, is intended to be deployed at out-patient points-of-care and hospitals, and it provides output parameters related to the PWV as measured at local and/or at regional level.\n\nNISTAS brings together four European SMEs in four different, but complementary, technology areas (JULIGHT, ECLEXYS, EPI-LIGHT, OIP) and links them with five RTD Performers (UNIPV, OSM, CORK UNIVERSITY, Saphyrion, Eudax srl ) to develop new knowledge and a new medical device which will have significant commercial benefits for all of the SME partners.\n\nVascuLight responds to an unmet need in the medical diagnosis practice: the request for a fast and sustainable method for the screening of the health of the vascular system in large series, capable of providing a reliable indicator of the cardiovascular risk of the screened subjects.\n\nThe VascuLight idea is founded on a paradigm shift: bringing and adapting to the biomedical field measurement techniques that are to date confined to the industrial environment. NISTAS will develop new non-contact distance/displacement/vibration sensors based on a variant of the well-known and reliable laser triangulation technique.\n\nJUL and UNIPV have carried out proof-of-concept, in-vivo tests of the VascuLight approach to demonstrate that the concept is realistic and attainable. Results have been obtained using Laser Doppler Vibrometry (LDV), a displacement-measuring technique based on the principle of light interference, and an area where both JUL and UNIPV have made important contributions. In the tests it was possible to use TWO small LDV optical heads to simultaneously measure the pulse wave in two points on the carotid spaced by 2.5 cm, allowing for the calculation of the time-delay between the pulse waves, and thus providing a direct local measurement of the PWV.\n\nThe aim of the study is to test the implemented contactless optical technique for the measurement of the PWV and the arterial stiffness at the carotid artery level.\n\nTo evaluate the validity of the measure method, the investigators will compare Vasculight v1.0 PWV measures with those obtained from e-tracking (echocardiographic method) . The main idea is to compare the distribution of measures (comparable mean and standard deviation) in the same mixed adult population, using the two different methods.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'maximumAge': '65 Years', 'minimumAge': '18 Years', 'healthyVolunteers': True, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Age 18-65\n\nExclusion Criteria:\n\n1. Systolic BP \\>160 mmHg or diastolic BP \\>100 mmHg\n2. Treated hypertension\n3. Diagnosis of type 1 or type 2 diabetes mellitus\n4. Treated hypercholesterolaemia\n5. Past or current, symptomatic or proven, coronary artery disease\n6. Clinical cerebrovascular disease\n7. Carotid arterial stenosis\n8. Severe peripheral vascular disease\n9. Hypertrophic or dilated cardiomyopathy\n10. Congestive heart failure\n11. Heart valve disease\n12. Previous cardiac surgery\n13. Congenital heart disease\n14. Other systemic diseases such as cancers, endocrine diseases and autoimmune diseases\n15. Any regular drug treatment'}, 'identificationModule': {'nctId': 'NCT02392260', 'acronym': 'NISTAS1', 'briefTitle': 'Non-invasive Screening of the Status of the Vascular System: Feasibility Test', 'organization': {'class': 'OTHER', 'fullName': 'University of Pavia'}, 'officialTitle': 'Non-invasive Screening of the Status of the Vascular System: Feasibility Test', 'orgStudyIdInfo': {'id': '20140008054'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Vasculight prototype zero level', 'interventionNames': ['Device: Vasculight']}], 'interventions': [{'name': 'Vasculight', 'type': 'DEVICE', 'description': 'Comparative measre of Pulse Wave velocity with both Vasculight prototype and Echocardiographic machine.', 'armGroupLabels': ['Vasculight prototype zero level']}]}, 'contactsLocationsModule': {'centralContacts': [{'name': 'Valentina Favalli, BME', 'role': 'CONTACT', 'email': 'v.favalli@smatteo.pv.it', 'phone': '0039 0382 501487'}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'University of Pavia', 'class': 'OTHER'}, 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'Biomedical Engeneer', 'investigatorFullName': 'Valentina Favalli', 'investigatorAffiliation': 'Fondazione IRCCS Policlinico San Matteo di Pavia'}}}}