Viewing Study NCT01440894


Ignite Creation Date: 2025-12-25 @ 1:40 AM
Ignite Modification Date: 2025-12-26 @ 1:39 AM
Study NCT ID: NCT01440894
Status: COMPLETED
Last Update Posted: 2011-09-27
First Post: 2011-09-25
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Clinical Trail of Transtek Glass Body Fat Analyzer
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D001835', 'term': 'Body Weight'}], 'ancestors': [{'id': 'D012816', 'term': 'Signs and Symptoms'}, {'id': 'D013568', 'term': 'Pathological Conditions, Signs and Symptoms'}]}}, 'protocolSection': {'designModule': {'studyType': 'OBSERVATIONAL', 'designInfo': {'timePerspective': 'RETROSPECTIVE', 'observationalModel': 'COHORT'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 50}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2011-02'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2011-09', 'completionDateStruct': {'date': '2011-02', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2011-09-25', 'studyFirstSubmitDate': '2011-09-25', 'studyFirstSubmitQcDate': '2011-09-25', 'lastUpdatePostDateStruct': {'date': '2011-09-27', 'type': 'ESTIMATED'}, 'studyFirstPostDateStruct': {'date': '2011-09-27', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2011-02', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Verify the accuracy of measure functions of device', 'timeFrame': '8 days', 'description': 'Verify the functions and efficiency of these devices compare with a specified product.'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'keywords': ['weight', 'body fat', 'total body water', 'bone mass', 'muscle mass'], 'conditions': ['Weight', 'Body Fat Disorder', 'Bone Mass']}, 'referencesModule': {'seeAlsoLinks': [{'url': 'http://www.zsph.com/', 'label': 'Related Info'}]}, 'descriptionModule': {'briefSummary': 'The clinical protocol of the clinical testing of this device:\n\n1. Objective of the test: To verify the functions and efficiency of devices.\n2. Test methods and procedures: Comparison Test.\n3. DUT(Device Under Test): Transtek Glass Body Fat Analyzer, Model: GBF-733-W1, GBF-1012, BF-1039, BF-1041-A, and GBF-950-D.\n4. Comparison device: Transtek Glass Body Analyzer, GBF-950 (Predicate Device).\n5. Study endpoints: Transtek devices and the predicate device are substantial equivalence.\n6. Statistical methodology used: Description of statistical methods.\n7. Result: Efficiencies of Transtek devices and predicate device are in the same level.', 'detailedDescription': "Hospital Information The data was collected by Zhongshan City People's Hospital Clinical Investigator Team at Zhongshan City People's Hospital, No.2 Sunwen Dong Road, Zhongshan, Guangdong 528403, P. R. China.\n\nInvestigator: Dr. Stephen Feng, Leader; Fan Futao, Nurse A; Wu Yanting, Nurse B.\n\nContact Dr. James Zhu Tel: +86 760 88823818 Used Equipments DUT (Device Under Test): Transtek Glass Body Fat Analyzer, Model: GBF-733-W1, GBF-1012, BF-1039, BF-1041-A, and GBF-950-D.\n\nReference Device: Transtek Glass Body Analyzer, GBF-950 (Predicate Device). Test Protocol\n\n1. Test Purpose:\n\n The aim of clinical test is to collect weight, body fat, total body water, bone mass, and muscle mass reading value which measured by DUT and reference device.\n\n Note: GBF-733-W1 and BF-1039 have not bone mass functions. So it just collects weight, body fat, total body water, and muscle mass data.\n2. Target Subject:\n\n The subject database shall contain at least 25 male and 25 female subjects and all above 18 years old. Patient's population analysis is bellow.\n3. Test procedures 1) Record the name, age, and gender values of each subject. 2) Let subject seated calmly for two minutes before test, dry the feet. 3) Use device to measure weight, body fat, total body water, bone mass, and muscle mass; record reading value.\n\n4\\) For each subject, repeat 3) to get 3 pairs measurements. 5) Repeat step 1) to 4) for every device (DUT: GBF-733-W1, GBF-1012, BF-1039, BF-1041-A, and GBF-950-D; and reference device: GBF-950).\n\n6\\) Repeat step 1) to 5) for each subject. 5. Note:\n\n1. No motion and speaking are allowed during the measurement.\n2. All DUT use the same algorithms, have the same number of electrodes and contact the patient at the same body locations (feet), and operate on the same frequency.\n3. Test environment: Temperature: 22±1℃; Relative humidity: 40\\~50%."}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '18 Years', 'samplingMethod': 'PROBABILITY_SAMPLE', 'studyPopulation': 'The subject population included patients whose age is above 18 years old. Male or Female.', 'healthyVolunteers': True, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* male,female\n\nExclusion Criteria:\n\n* below 18 years old'}, 'identificationModule': {'nctId': 'NCT01440894', 'acronym': 'GBFA', 'briefTitle': 'Clinical Trail of Transtek Glass Body Fat Analyzer', 'organization': {'class': 'OTHER', 'fullName': 'BTS International'}, 'officialTitle': 'Verify the Functions and Efficiency of Transtek Glass Body Fat Analyzer, GBF-733-W1, GBF-1012, BF-1039, BF-1041-A, GBF-950-D.', 'orgStudyIdInfo': {'id': 'TranstekGBFA11003'}, 'secondaryIdInfos': [{'id': 'BTS-TRANS03', 'type': 'OTHER', 'domain': 'BTSInternational'}]}, 'armsInterventionsModule': {'armGroups': [{'label': 'Body Analysis', 'interventionNames': ['Device: Comparison test']}], 'interventions': [{'name': 'Comparison test', 'type': 'DEVICE', 'otherNames': ['Brand name: Transtek'], 'description': 'Reference Device: Transtek Glass Body Analyzer, GBF-950, accuracy: ±0.1kg and range: 0-180kg.\n\nDUT(Device Under Test): Transtek Glass Body Fat Analyzer, Model: GBF-733-W1, GBF-1012, BF-1039, BF-1041-A, and GBF-950-D.', 'armGroupLabels': ['Body Analysis']}]}, 'contactsLocationsModule': {'locations': [{'zip': '528403', 'city': 'Zhongshan', 'state': 'Guangdong', 'country': 'China', 'facility': "Zhongshan City People's Hospital", 'geoPoint': {'lat': 22.52306, 'lon': 113.37912}}], 'overallOfficials': [{'name': 'Stephen Feng, Director', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': "Zhongshan People's Hospital, Guangdong, China"}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Leo Wang', 'class': 'OTHER'}, 'collaborators': [{'name': 'BTS International', 'class': 'OTHER'}], 'responsibleParty': {'type': 'SPONSOR_INVESTIGATOR', 'investigatorTitle': 'Team leader', 'investigatorFullName': 'Leo Wang', 'investigatorAffiliation': 'BTS International'}}}}