Viewing Study NCT01131793


Ignite Creation Date: 2025-12-25 @ 1:26 AM
Ignite Modification Date: 2025-12-27 @ 11:09 PM
Study NCT ID: NCT01131793
Status: COMPLETED
Last Update Posted: 2011-07-20
First Post: 2010-05-20
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: PowerAssert Radio-Frequency (RF) Guidewire Coronary In-Stent Chronic Total Occlusion (CTO)
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D003324', 'term': 'Coronary Artery Disease'}], 'ancestors': [{'id': 'D003327', 'term': 'Coronary Disease'}, {'id': 'D017202', 'term': 'Myocardial Ischemia'}, {'id': 'D006331', 'term': 'Heart Diseases'}, {'id': 'D002318', 'term': 'Cardiovascular Diseases'}, {'id': 'D001161', 'term': 'Arteriosclerosis'}, {'id': 'D001157', 'term': 'Arterial Occlusive Diseases'}, {'id': 'D014652', 'term': 'Vascular Diseases'}]}}, 'protocolSection': {'designModule': {'phases': ['PHASE2'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'TREATMENT', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 5}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2010-03'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2011-07', 'completionDateStruct': {'date': '2011-03', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2011-07-19', 'studyFirstSubmitDate': '2010-05-20', 'studyFirstSubmitQcDate': '2010-05-25', 'lastUpdatePostDateStruct': {'date': '2011-07-20', 'type': 'ESTIMATED'}, 'studyFirstPostDateStruct': {'date': '2010-05-27', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2011-03', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Primary RF wire success', 'timeFrame': 'Assessed and measured during interventional procedure up to discharge-average hospital stay 1-5 days- defined in protocol as the number of days between interventional treatment and hospital discharge', 'description': 'Defined as reaching the true lumen of any branch distal to the total occlusion with the sole use of the RF wire with absence of major complications (Myocardial Infarction (MI), tamponade, emergency Cornary Artery Bypass graft (CABG) or death)'}], 'secondaryOutcomes': [{'measure': 'Facilitated RF wire Success: Procedure Success: Clinical Success', 'timeFrame': 'Assessed and measured during interventional procedure up to discharge-average hospital stay 1-5 days- defined in protocol as the number of days between interventional treatment and hospital discharge', 'description': 'Facilitated RF wire success is defined as reaching the true lumen of any branch distal to the total occlusion with combined use of the RF wire and any approved mechanical guidewire with absence of major complications Procedure success defined as in-hospital device success and final residual stenosis \\< 30% on visual assessment, following adjunctive angioplasty, with absence of major complications Clinical success defined as device and procedure success during the concurrent hospital stay with absence of major complication'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'keywords': ['Coronary Artery Chronic Total Occlusion In-Stent'], 'conditions': ['Coronary Artery Disease']}, 'descriptionModule': {'briefSummary': 'A single center Pilot Clinical Registry Study of the" Acute Procedural" Safety and Efficacy of Stereotaxis PowerAssert(TM)RF Coronary Total Occlusion System assisted Angioplasty in the Treatment of Refractory Coronary Total Occlusions', 'detailedDescription': 'Determine the safety and efficacy of the Stereotaxis PowerAssertâ„¢ 18 RF Wire System:\n\nPrimary - of recanalizing (crossing) coronary total occlusions within a stent.\n\nSecondary - facilitated angioplasty at hospital discharge represented by\n\n* Event free survival\n* Anginal status, and\n* Target vessel patency\n* minimal luminal diameter (MLD).'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '18 Years', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Patient eligible for elective revascularization of a native coronary vessel\n* Patient has refractory coronary total occlusion (Thrombolysis In Myocardial Infarction (TIMI) 0 flow) within a stent\n* Written Informed Consent obtained\n\nExclusion Criteria:\n\n* Under 18 years of age\n* Current participation in another study with any investigational drug or device\n\n -\\>TIMI 0 flow at target lesion site\n* Lesion \\>40mm. in length\n* Factors making follow-up or repeat angiography difficult or unlikely\n* Acute myocardial infarction less than 1 month before angioplasty\n* Contra-indication to emergency coronary artery bypass surgery\n* No access to cardiac surgery\n* Contra-indication to treatment with aspirin, ticlopidine, clopidogrel or heparin\n* Angiographic evidence of thrombus (filling defect proximal to or involving the occlusion)\n* Occluded ostium of the right coronary artery or stem of left main coronary artery as target lesion\n* Totally occluded bypass graft as target vessel\n* Occlusion in an unprotected left main coronary artery\n* Ejection fraction less than 30%\n* Lesion beyond acute bends or in a location within the coronary anatomy where the catheter cannot traverse\n* Lesion within a bifurcation with a significant sidebranch \\>1.5mm in diameter'}, 'identificationModule': {'nctId': 'NCT01131793', 'acronym': 'TOTAR', 'briefTitle': 'PowerAssert Radio-Frequency (RF) Guidewire Coronary In-Stent Chronic Total Occlusion (CTO)', 'organization': {'class': 'INDUSTRY', 'fullName': 'Stereotaxis'}, 'officialTitle': 'Total Occlusion With Angioplasty After Using a Radiofrequency Guide Wire-Magnetic-Coronary', 'orgStudyIdInfo': {'id': 'CLIN-019'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'RF Guidewire', 'interventionNames': ['Device: PowerAssert RF wire in crossing coronary in-stent chronic total occlusions']}], 'interventions': [{'name': 'PowerAssert RF wire in crossing coronary in-stent chronic total occlusions', 'type': 'DEVICE', 'otherNames': ['PowerAssert RF', 'Magnetic RF Wire'], 'description': 'Radio frequency ablation of chronic total occlusions within a stent of a coronary artery using Niobe Magnetic Navigation System (MNS) and the PowerAssert Radiofrequency Guidewire', 'armGroupLabels': ['RF Guidewire']}]}, 'contactsLocationsModule': {'locations': [{'city': 'Rotterdam', 'state': 'The Netherlands', 'country': 'Netherlands', 'facility': 'Erasmus MC University Medical Center', 'geoPoint': {'lat': 51.9225, 'lon': 4.47917}}], 'overallOfficials': [{'name': 'Projessor Patrick W. Serruys, PhD', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Erasmus Medical University Thoraxcenter'}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Stereotaxis', 'class': 'INDUSTRY'}, 'responsibleParty': {'oldNameTitle': 'Mark Jacob', 'oldOrganization': 'Stereotaxis Inc'}}}}