Viewing Study NCT02017093


Ignite Creation Date: 2025-12-25 @ 1:19 AM
Ignite Modification Date: 2026-01-14 @ 7:19 PM
Study NCT ID: NCT02017093
Status: COMPLETED
Last Update Posted: 2016-01-13
First Post: 2013-06-20
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: Error Enhancement of the Velocity Component
Sponsor: University of Haifa
Organization:

Study Overview

Official Title: Error Enhancement of the Velocity Component in the Course of Stroke Patients' Reaching Movements - A Pilot Study
Status: COMPLETED
Status Verified Date: 2015-06
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The purpose of this pilot study was to explore the impact of enhancement of the velocity component error in the course of reaching movements of the impaired/hemiparetic limb in an acute stroke subject. We hypothesized that the method would shift velocity profiles toward the optimal, resulting in a reduction in error. A prototype robot. This robotic device system has a two-dimensional motor, basic measurement capacities, and a robotic arm which is engaged to the subject's upper-limb in a sitting position.

The enhancement of the velocity component error would shift velocity profiles toward the optimal, resulting in a reduction in error.
Detailed Description: The wrist of the subject is connected to the robotic arm by a strip which supports the arm but allows free movements of the wrist. This configuration allows subjects with impaired grasping ability to use the system. A bio-feedback system enables the subject to perform various functional motor tasks that are presented on the screen in front of him. The system's sensors detect motor errors or deviations from an optimal/proper movement trajectory or velocity profile. Any deviation in direction, velocity, acceleration or necessary force from the optimal trajectory results in applied robotic forces that enhance such errors/deviations. The sensors and the applied forces all work and compute in real time, so that the force measurements and the applied force are updated to the executed movement.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
CEli REGISTRY Eli Carmeli View