Viewing Study NCT03505593


Ignite Creation Date: 2025-12-25 @ 1:11 AM
Ignite Modification Date: 2025-12-25 @ 11:22 PM
Study NCT ID: NCT03505593
Status: COMPLETED
Last Update Posted: 2020-09-10
First Post: 2018-04-09
Is NOT Gene Therapy: False
Has Adverse Events: True

Brief Title: Feasibility Study to Evaluate Safety of ENvizion Medical™ ENVUE™ System
Sponsor: Envizion Medical Ltd.
Organization:

Study Overview

Official Title: A Feasibility Study to Evaluate the Clinical Safety of ENvizion Medical™ Enteral Feeding Tube Placement Using the ENvizion Medical™ ENVUE™ System in Patients
Status: COMPLETED
Status Verified Date: 2020-03
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: This is a single center, non-randomized feasibility clinical evaluation that is designed to affirm the safety of the ENVUE™ System guidance during the placement of the ENvizion Medical™ enteral feeding tubes.
Detailed Description: Enteral nutrition is the preferred route for the provision of nutritional support in most critical ill patients with functional gastrointestinal tract. Achieving early enteral nutrition (EN) in critically ill patients is associated with fewer major complications, reduced mortality and length of hospital stay, and significant cost savings. It is estimated that approximately 1.2 million feeding tubes are placed blindly each year in the United States alone. Despite the obvious advantages of the enteral tube feeding, inadvertent placement of Enteral Feeding Tube (EFT) into the airway is relatively common and can result in significant pulmonary injury including pneumothorax and pneumonia. Airway misplacement occurs in 1.2- 4 % of blind EFT insertions, with 0.2 to 1.2% of all the feeding tube placements cause pulmonary complications to patients. The gold standard for detecting inadvertent placement of a feeding tube in the lungs is radiography. However, because of its cost, possible delay of feedings while waiting for radiography, and risk for radiation exposure, clinicians continue to seek for alternative methods to confirm correct placement.

All the above mentioned, emphasizes the fact that safe and effective delivery of nasoenteral tube feedings requires assurance that the feeding tube tip is in a proper position. The ENVUE™ System is an electromagnetic tracking system which tracks the path of the feeding tube during placement. The benefit of the system when EFT is misdirected into the pulmonary system is a real-time visual tracing, which may prompt users to withdraw the tube and reinsert it.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: True
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: True
Is an FDA AA801 Violation?: