Viewing Study NCT05887193


Ignite Creation Date: 2025-12-25 @ 1:06 AM
Ignite Modification Date: 2025-12-25 @ 11:18 PM
Study NCT ID: NCT05887193
Status: COMPLETED
Last Update Posted: 2023-06-02
First Post: 2023-04-21
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Comparison of Penile Oxygen Pressure.
Sponsor: Charles University, Czech Republic
Organization:

Study Overview

Official Title: Comparison of Penile Oxygen Pressure: Comparison of Conventional and 3D Custom-made Saddle
Status: COMPLETED
Status Verified Date: 2023-04
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Aim of this study is to compare novel 3D printed cycling saddle with the best selling saddle from two major cycling manufacturers in terms of effects on blood circulation in the peritoneal region.
Detailed Description: The aim of this thesis is to investigate whether Joyseat's 3D printed and custom-made bicycle saddles provide a benefit in terms of increased penile blood flow compared to the best-selling saddles from two major bicycle manufacturers. The method chosen to measure blood flow, which is commonly used in studies of this type, is referred to as Near Infrared Spectroscopy. Measurement of tcpO2 and tcpCO2 in cyclists will be performed while riding on a cycling trainer using Radiometer TCM5 Flex (Radiometer Medical ApS, Brønshøj, Denmark) and a tc 84 electrode placed on the glans penis. Prior to the actual penile blood flow measurements, the sensitivity level of the n. pudendus (n. dorsalis penis) will be verified using biothesiometry (electronic tuning fork test, vibration), which is again commonly used in studies of this type. The pressure of the rider's contact surfaces on the saddle will be evaluated with pressure mat (Gebiomized GmbH, Münster, Germany). The Wahoo Bike (Wahoo Fitness, Limited Liability Company, Atlanta, Georgia, United States of America) will be used in the study, which, in addition to the possibility of individual seating adjustment, also allows to record the cyclist's power and heart rate using a chest strap. The cyclist's position on the bike will be measured and evaluated by infrared sensors and Retül technology (Retül, Specialized Bicycle Components Inc., Boulder, Colorado, United States of America). The test will be performed on the described instrumentation in the Applied Kinesiology Laboratory at Charles University in Prague, Faculty of Physical Education and Sports and will involve a maximum of 3x 20 min rides on the cycle trainer at 65-85% of the cyclist's maximum individual heart rate during one visit. All measurement methods and devices are non-invasive and painless. The choice of instruments was based on their use in previously published studies of similar type and on their quality, i.e., the parameters of validity, reliability, sensitivity, specificity and availability.

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: