Viewing Study NCT05233293


Ignite Creation Date: 2025-12-25 @ 1:06 AM
Ignite Modification Date: 2025-12-25 @ 11:18 PM
Study NCT ID: NCT05233293
Status: UNKNOWN
Last Update Posted: 2023-08-15
First Post: 2022-01-14
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Spyglass+RFA Versus Cytobrush+RFA for Extrahepatic Cholangiocarcinoma
Sponsor: First People's Hospital of Hangzhou
Organization:

Study Overview

Official Title: Comparison of SpyGlass Guided RFA On The Same Stage Versus RFA After Cytobrush for Extrahepatic Cholangiocarcinoma
Status: UNKNOWN
Status Verified Date: 2023-08
Last Known Status: ENROLLING_BY_INVITATION
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: With the development of endoscopic technology, endoscopic retrograde cholangiopancreatography (ERCP) has been widely used in the diagnosis and treatment of extrahepatic cholangiocarcinoma.In patients with extrahepatic cholangiocarcinoma, cytological brushing performed concurrently with ERCP had a lower pathologically positive rate and increased the times of ERCPs, increased the risk of postoperative complications at the same time.The present study aims to compare the efficacy and safety outcomes of Spyglass+RFA Versus Cytobrush+RFA for Extrahepatic Cholangiocarcinoma.
Detailed Description: Endoscopic retrograde cholangiopancreatography (ERCP) has been used as the primary method for the diagnosis of biliary strictures and the treatment of extrahepatic cholangiocarcinoma. However, the accurate visual diagnosis of malignant biliary strictures and assessment of the extent of a lesion are not possible by ERCP, and treatment of extrahepatic cholangiocarcinoma by ERCP procedures is sometimes difficult. In patients with extrahepatic cholangiocarcinoma, cytological brushing performed concurrently with ERCP had a lower pathologically positive rate and increased the times of ERCPs, increased the risk of postoperative complications at the same time. Spyglass enables direct visualization of the biliary tract and the sampling of suspicious lesions, together with radiofrequency ablation.Endoscopic radiofrequency ablation (RFA) is an emerging technique for the palliation of inoperable malignant biliary strictures (MBSs). In a dozen published studies, this novel approach has shown better safety and feasibility, as well as improvement in overall survival (OS). The present study aims to compare the efficacy and safety outcomes of Spyglass+RFA Versus Cytobrush+RFA for Extrahepatic Cholangiocarcinoma.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: