Viewing Study NCT03296293


Ignite Creation Date: 2025-12-25 @ 12:56 AM
Ignite Modification Date: 2026-01-04 @ 1:30 AM
Study NCT ID: NCT03296293
Status: COMPLETED
Last Update Posted: 2017-10-02
First Post: 2017-09-18
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Effects of Positive End-expiratory Pressure on Intracranial Pressure in Patients With Severe Traumatic Brain Injury
Sponsor: Hongpeng Li
Organization:

Study Overview

Official Title: Doctor of Department of Emergency and Critical Care Medicine, Zhoupu Hospital Affiliated With Shanghai University of Medicine and Health Sciences, Shanghai 201318, PR China
Status: COMPLETED
Status Verified Date: 2017-09
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: PEEP,ICP,CVP
Brief Summary: The impact of PEEP on ICP was dependent on the difference between elevated CVP levels and baseline ICP levels. ICP would increase once elevated CVP through PEEP adjustment exceeds the baseline ICP.
Detailed Description: all patients were exposed to incremental PEEP levels of 0, 5, 10, and 15cmH2O with 100% of FiO2. The measurements were done bedside on stabilized hemodynamics and intracranial pressure. The measurement was discontinued if the following situation presented and remedies were applied accordingly: (1) CPP \< 60 mmHg (norepinephrine at 0.3\~1.0μg/kg.min was used); (2) ICP \> 25 mmHg (PEEP was restored to 0); (3) increase of pressure plateau \> 35 cmH2O (tidal volume was decreased and PetCO2 was maintained at 30\~35mmHg); (4) SpO2 \< 90% (PEEP was restored to 0); and (5) suspicion of pneumothorax (PEEP was restored to 0 and chest radiography was performed). An equilibration period (at least 90 seconds) was entailed to ensure a normalized baseline PetCO2 through modulating tidal volume and respiratory rate.

ICP, CVP, Pj, and MAP were measured twice or more at each level of PEEP for consecutively five days after admission. CPP was calculated according to the following equation: CPP=MAP-ICP. The difference between baseline ICP and CVP was categorized into the following three groups according to the previous findings: Group I,IVPD ≤ 3mmHg, Group II, 3 \< IVPD ≤ 6 mmHg, Group III, IVPD \> 6 mmHg. Relationships between PEEP and ICP, CVP and MAP, CVP and Pj were analyzed in each group respectively.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: