Viewing Study NCT04412967


Ignite Creation Date: 2025-12-25 @ 12:45 AM
Ignite Modification Date: 2025-12-25 @ 10:58 PM
Study NCT ID: NCT04412967
Status: COMPLETED
Last Update Posted: 2020-06-30
First Post: 2020-05-27
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Nurse-led Placement of Peripheral Venous Catheters in Overweight Patients Using Standard or Dynamic Ultrasound-guided Technique
Sponsor: University Hospital, Linkoeping
Organization:

Study Overview

Official Title: A Randomized, Controlled Comparison of Nurse-led Placement of Peripheral Venous Catheters in Overweight Patients Using Standard or Dynamic Ultrasound-guided Technique
Status: COMPLETED
Status Verified Date: 2020-06
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: DUST
Brief Summary: Overweight and obesity may be associated with difficult intravenous access leading to longer procedure time and more placement attempts of peripheral venous catheters (PVC). Dynamic ultrasound-guided short-axis needle tip navigation (DUST) may facilitate the procedure.

This was a prospective, randomized, non-blinded study to compare time and placement attempts for nurse-led standard (ST) and ultrasound guided PVC placement in 90 emergency patients with a BMI ≥25kg/m2.

Consenting patients were randomized at a 1:1 ratio to receive PVC by either ST or DUST.

Application time was defined as the time from applying stasis to visible blood in the PVC flash-chamber.

No difference in time was found (medians: ST 42 s; DUST 53.5 s, P = 0.535). There were on average 17 % less placement attempts in the DUST-group (median 1 attempt; Q1 = 1 Q3 = 1) compared to the ST-group (median 1 attempt; Q1 = 1 Q3 = 1.5), (p = 0.031). Patients reported no differences in perceived pain (p = 0.955) or perceived satisfaction (p = 0.342). Pain and subcutaneous infiltrations were the only side-effects reported (ST-group 6, DUST-group 5).

DUST does not decrease time to functional PVC but reduces the number of PVC placement attempts in patients with BMI ≥25 kg/m2.
Detailed Description: None

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: