Viewing Study NCT01185652



Ignite Creation Date: 2024-05-05 @ 10:46 PM
Last Modification Date: 2024-10-26 @ 10:24 AM
Study NCT ID: NCT01185652
Status: UNKNOWN
Last Update Posted: 2011-05-13
First Post: 2010-08-18

Brief Title: A Study on Smoking-related Lung Function Abnormalities and Correlation With Serum Biomarkers in Chinese
Sponsor: The University of Hong Kong
Organization: The University of Hong Kong

Study Overview

Official Title: A Study on Smoking-related Lung Function Abnormalities and Correlation With Serum Biomarkers in Chinese
Status: UNKNOWN
Status Verified Date: 2011-05
Last Known Status: RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Tobacco-smoking causes lung function decline with airflow obstruction which may be accelerated in persistent smokersThis would eventually lead to chronic obstructive pulmonary disease COPD a leading cause of morbidity and mortality in Hong Kong and globally Lung function decline is gradual and not appreciated by the smoker until damage is advanced and often under-recognised in the early stages of disease by healthcare providers Spirometry is an established lung function measurement tool and the most simple objective method to detect lung function decline There is literature suggesting that newer spirometric parameters FEV3 and FEV6 which are easier to achieve in the measurement process than conventional parameters are comparable alternatives in detecting lung function decline

The aims of this study are

1 to evaluate and compare lung function decline in persistent smokers and non-smokers
2 to study the usefulness of FEV3FVC and FEV1FEV6 in detecting lung function decline
3 to correlate symptom scores with lung function parameters
4 To correlate serum biomarker levels with respiratory symptoms and lung function parameters in smokers and non-smokers

This is a follow-up study on a territory wide cohort including smokers and non-smokers who have undergone lung function testing in 2001-03 Subjects will be invited to have repeat lung function assessment

The hypotheses of this study are

1 smokers have significantly greater decline in lung function compared to non-smokers in Hong Kong Chinese
2 newer lung function parameters are useful alternatives in detecting lung function decline
3 serum inflammatory biomarker IL-8 TGF-β MMP9 TIMP-1 CRP levels correlate with respiratory symptoms and lung function parameters in smokers when compared with non-smokers
Detailed Description: Tobacco-smoking causes lung function decline with airflow obstruction which may be accelerated in persistent smokersThis would eventually lead to chronic obstructive pulmonary disease COPD a leading cause of morbidity and mortality in Hong Kong and globally Lung function decline is gradual and not appreciated by the smoker until damage is advanced and often under-recognised in the early stages of disease by healthcare providers Spirometry is an established lung function measurement tool and the most simple objective method to detect lung function decline There is literature suggesting that newer spirometric parameters FEV3 and FEV6 which are easier to achieve in the measurement process than conventional parameters are comparable alternatives in detecting lung function decline

The aims of this study are

1 to evaluate and compare lung function decline in persistent smokers and non-smokers
2 to study the usefulness of FEV3FVC and FEV1FEV6 in detecting lung function decline
3 to correlate symptom scores with lung function parameters
4 To correlate serum biomarker levels with respiratory symptoms and lung function parameters in smokers and non-smokers

This is a follow-up study on a territory wide cohort including smokers and non-smokers who have undergone lung function testing in 2001-03 Subjects will be invited to have repeat lung function assessment

The demonstration of excessive lung function decline in the local smoking population would reinforce the anti-tobacco message in the community Establishing the practical utility of newer lung function parameters can help to disseminate their utilization for early objective health information which would provide incentives for healthcare professionals as well as individual smokers in the pursuance of smoking cessation

The hypotheses of this study are

1 smokers have significantly greater decline in lung function compared to non-smokers in Hong Kong Chinese
2 newer lung function parameters are useful alternatives in detecting lung function decline
3 serum inflammatory biomarker IL-8 TGF-β MMP9 TIMP-1 CRP levels correlate with respiratory symptoms and lung function parameters in smokers when compared with non-smokers

Subjects In 2001 - 2003 we conducted a multi-center study to recruit 1089 non-smokers for establishing local reference lung function values and 694 smokers for investigating the diagnostic definition of airflow obstruction The cohort was derived from a random population sample and the characteristics of the two cohorts have been described in detail in previous communications All subjects will be invited to return for spirometry testing We would compare their lung function parameters 7 years ago with the repeat measurements obtained in this study

Methods

i Subjects will be interviewed using a questionnaire based on the ATS Questionnaire for Chronic Respiratory Symptoms In addition a detailed smoking history will be asked for those who have given up smoking in the interval between the previous study and this study the time of quitting will be recorded

ii Spirometry Spirometry with bronchodilator testing will be performed according to the ATS-ERS guidelines using Sensormedics Vmax 229 All participating centers are experienced in lung function testing Quality control of the tests will be ensured by 1 standardization and calibration of the equipments prior to commencement of study 2 briefing session for all involved technicians conducted by a senior technician 3 technical quality of raw data will be scrutinized by a respiratory specialist iii Seum biomarkers Recruited subjects will be invited to give 10 ml blood in the same lung function test session

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None