Viewing Study NCT06893367


Ignite Creation Date: 2025-12-25 @ 12:27 AM
Ignite Modification Date: 2025-12-25 @ 10:32 PM
Study NCT ID: NCT06893367
Status: NOT_YET_RECRUITING
Last Update Posted: 2025-03-25
First Post: 2025-03-06
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Reliability of Sensor-Derived Measurements of the SENSorized Fugl-Meyer (FMA) in Subjects with Stroke Outcomes
Sponsor: Fondazione Don Carlo Gnocchi Onlus
Organization:

Study Overview

Official Title: Reliability of Sensor-Derived Measurements of the SENSorized Fugl-Meyer (FMA) in Subjects with Stroke Outcomes
Status: NOT_YET_RECRUITING
Status Verified Date: 2025-03
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: FMA-SENS
Brief Summary: This study will be conducted at a single research center, the main objective of the study will be to evaluate the efficacy, safety, and accuracy of a medical device that has not yet been commercialized; therefore, it is still under development or testing and is not yet available for private use and is not for profit (nonprofit).

Fifty participants will be recruited from subjects afferent to the outpatient and inpatient neuro-motor rehabilitation clinics of IRCCS Fondazione Don Carlo Gnocchi in Florence, Italy, and afferent to the outpatient and inpatient rehabilitation clinics of Elias University Emergency Hospital in Bucharest, Romania.

In detail, it is deemed necessary to collect clinical and instrumental data. The study will be conducted by an interdisciplinary team composed of healthcare professionals and engineers afferent to the Department of Industrial Engineering.

Should you decide to participate in the study, a visit to verify the inclusion and exclusion criteria will be primarily conducted. Once the admission criteria have been verified, participants will undergo a series of assessments.

The first, involves the administration of some specific sections of the Fugl-Meyer scale (FMA), focusing on the upper extremities. Specifically, the following will be examined: section A for general upper limb function, section B assessing wrist mobility, and finally section D for limb coordination and speed.

During this phase, both upper limbs will be assessed, in addition, the first examiner will carefully place sensors on the participants and assign scores to the tests performed, according to the criteria established by the FMA scale.

Next, a second assessment (T1) will be conducted, in which a second examiner will be responsible for placing the sensors and recording data only on the most affected side.

At a third time, called "T2" and again with at least 15 minutes interval from T1, the first examiner will repeat the same assessments performed in "T1." While performing these assessments, a RealSense camera will be used.
Detailed Description: None

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: False
Is an FDA AA801 Violation?: