Viewing Study NCT06667258


Ignite Creation Date: 2025-12-25 @ 12:22 AM
Ignite Modification Date: 2025-12-25 @ 10:25 PM
Study NCT ID: NCT06667258
Status: RECRUITING
Last Update Posted: 2024-10-31
First Post: 2024-10-24
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Hearables: Ear-ECG and PPG for Detection of Cardiac Arrhythmias
Sponsor: Imperial College London
Organization:

Study Overview

Official Title: Hearables: Ear Electrocardiography (ECG) and Photoplethysmography (PPG) for Real-time Detection of Cardiac Arrhythmias
Status: RECRUITING
Status Verified Date: 2024-10
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The goal of this observational study is to determine the feasibility of detecting abnormal heart rhythms, known as arrhythmias, by recording Electrocardiogram (ECG) and Photoplethysmogram (PPG) waveforms from the ears in patients who have already been diagnosed with arrhythmias. The main questions it aims to answer are:

* Can ECG and PPG signals from the ears reliably detect arrhythmias?
* How do ear-based ECG/PPG waveforms compare to standard single-lead ECG in detecting abnormal rhythms?

Researchers will compare data from healthy controls and arrhythmia patients to see if ear-based recordings are as effective as traditional methods.
Detailed Description: The main goal of this study is to determine the feasibility of detecting abnormal heart rhythms, known as arrhythmias, by recording Electrocardiogram (ECG) and Photoplethysmogram (PPG) waveforms from the ears.

The study includes both healthy control subjects and patients who have already been diagnosed with arrhythmias. These individuals will be approached by a clinical member of the research team during their hospital stay or outpatient visit at Imperial College NHS Trust (ICHNT). Patients will be given comprehensive information about the study through a patient information sheet and will be asked for their written informed consent, with adequate time provided for questions and understanding.

To capture Ear-ECG/PPG waveforms, a variety of standard medical-grade sensors and electrodes will be placed in and around both ears. These include standard EEG electrodes on each mastoid secured with medical-grade gel, and an in-ear foam-based earpiece (like commercial earplugs) with cloth electrodes. An additional PPG sensor (MAX30101 from Maxim Integrated) will be attached to the back of the ear with adhesive medical tape. The patient will also be connected to a standard single-lead ECG and a blood pressure cuff, already part of their standard care on the hospital ward.

Once the setup is complete, each patient will follow 3 different recording protocols displayed on a screen. Patients will be asked to sit upright (Protocol 1) and engage in a series of simple activities with designated breaks in between, including head movements, counting aloud to 60, chewing gum (or simulating chewing), walking (if able) freely under medical supervision with assistance if needed (Protocol 2), slow controlled breathing and immersing their hand in cold water (Protocol 3). The total recording time including setup will be approximately 20 minutes.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
318229 OTHER IRAS View