Viewing Study NCT06850558


Ignite Creation Date: 2025-12-25 @ 12:20 AM
Ignite Modification Date: 2025-12-25 @ 10:24 PM
Study NCT ID: NCT06850558
Status: COMPLETED
Last Update Posted: 2025-08-17
First Post: 2025-02-15
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Patient's Satisfaction of Mandibular Implant Supported Overdentures With Reduced Denture Base Extensions.
Sponsor: Mansoura University
Organization:

Study Overview

Official Title: Patient's Satisfaction, Oral Health-related Quality of Life (OHRQoL) and Masticatory Efficiency of Mandibular Implant Supported Overdentures With Reduced Denture Base Extensions. A Within Subject Study
Status: COMPLETED
Status Verified Date: 2025-08
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: This study aimed to compare reduced (partially extended) denture bases with fully extended bases regarding patient satisfaction, oral health-related quality of life (OHRQoL), and masticatory efficiency.

A within-subject study design was carried out; involving 20 completely edentulous participants aged 50-75 years, who received newly constructed conventional complete denture. Four parallel implants were installed in the interforaminal region, implant overdenture (IOD) retained by bar attachment was constructed for each patient and were provided with two different overdenture designs: (1)firstly a fully extended denture base (FIOD) (2) then a reduced (partially extended) denture base (RIOD). Each patient allowed to wear each types of overdentures for a period of 3 months prior to evaluation. The following outcome measures were assessed: Patient satisfaction, the Oral Health Impact Profile (OHIP-14), and Chewing efficiency were assessed.
Detailed Description: Study Design This study is a within-subject comparison aimed at evaluating the effects of two different mandibular overdenture base designs: the Fully Extended Denture Base (FIOD) and the Reduced (Partially Extended) Denture Base (RIOD).

Study Protocol

1. Randomization: No randomization was done, the order of denture type presentation (was firstly fully extended then reduced design for each participant.
2. Adaptation Period: Participants were allowed a 3-months adaptation period for each Overdenture type to ensure familiarity and comfort.
3. Data Collection Schedule: Data for patient satisfaction, OHRQoL, and masticatory efficiency were collected at the end of each adaptation period. Data were collected at 3 months after use for each design, starting with FE design then RE.

Sample size and participants selection A total of 20 participants, aged 50-75 years, were recruited from the outpatient prosthodontic clinic, Faculty of Dentistry, Mansoura University. The sample size was determined based on a power analysis, aiming for an 80% power to detect significant differences at an alpha level of 0.05 and according to previous research in similar domains often utilized the same sample sizes.

Ethical Considerations The study was conducted in accordance with the Declaration of Helsinki, and ethical approval was obtained from the ethical committee, faculty of dentistry (A08011024RP). Informed consent was obtained from all participants prior to their involvement in the study. Participants were informed of their right to withdraw at any time without affecting their treatment.

Prosthetic and surgical procedures Newly constructed dentures with optimal flanges extension and balanced occlusal scheme using semi-anatomic acrylic teeth were delivered to all participants.

The participants were instructed to use the dentures for three months before implant placement to promote satisfactory neuromuscular control.

Following osseointegration duration, an open tray fixture level impression technique was performed using long transfer copings after splinting the copings with wire and auto polymerized resin (Duralay, Reliance Dental, Alsip, USA) to avoid movement during impression removal. The implant analogs were connected to the copings and the impression was poured. For Bar overdenture (BOD) prosthesis, plastic caps were screwed to bar abutments. Dolder bar joint plastic pattern (Dolder bar joint, Dentaurum) was lute to the caps with about 12mm distal cantilevers to reach the area of mandibular first molars. A 1-1.5 mm clearance space was kept between the ridge and the bar for cleaning reasons. The plastic bar was cast into cobalt-chromium and tried intraorally using Sheffield single screw test to check passivity. Titanium Dolder bar clips were fastened over the bar before processing of acrylic resin. The bar was then fitted with retentive clips or housings, which interfaced with the overdenture with fully extended base (FIOD), ensuring positive retention.

Following the 3 months period from FIOD mandibular implant overdenture use, data were collected then the overdenture was sent to the lab for reducing the denture base extension. The participant wore the mandibular implant overdenture with reduced denture base (Reduced Base Design) (RIOD) for another 3 months and the data were collected again .

Reduced (Partially Extended) Denture Base (RE): (R) A shorter base extending to the anterior portion of the mandible, designed to leave more space for tongue movement and enhance sensory feedback.

The design specifics are as follows:

\- Geometric Configuration: The reduced base extends anteriorly to cover the anterior residual ridge while curving gently around the retromolar pad area. The posterior border is strategically positioned above the retromolar area to prevent impingement on the tissues and to allow for greater tongue space.

Dimensions: The dimensions of the reduced base were tailored individually based on each patient's anatomical features. The following measurements were taken into account:

* Anterior extension cut-off: 2 mm above the anterior alveolar ridge.
* Posterior limit: 5 mm anterior to the retromolar pad, which allows for optimal retention and avoids undue pressure on the underlying tissues.
* Buccal and lingual flanges were designed with a tapered profile to enhance aesthetic and functional features while maintaining adequate reinforcement.

Retention Mechanism: The overdenture was retained by four osseointegrated implants using bar-type attachments. These mechanisms were chosen for their ease of use and effective retention while allowing for minimal stress on the remaining alveolar ridge.

Statistical analysis:

Descriptive statistics were represented in the form of Mean ±Standard deviation (SD) .data was normally distributed as detected by Shapiro-wilk test. To compare patient satisfaction and OHRQoL scores between the 2 overdenture designs, Un-paired samples t-test was utilized as it was parametric data. While Wilcoxon signed-rank tests was applied to evaluate differences in masticatory efficiency measures as it was non-parametric data. The software package used for data analysis was SPSS® version 25 (SPSS Inc., Chicago, IL, USA). The level of significance was adjusted at 5%.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: