Brief Title: Agreement and Accuracy of Different Devices for Biometry Measurements in Patients With Cataract
Sponsor: Medical University of Vienna
Organization:

Study Overview

Official Title: Agreement and Accuracy of Different Devices for Biometry Measurements in Patients With Cataract
Status: UNKNOWN
Status Verified Date: 2020-03
Last Known Status: RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: Comparison
Brief Summary: The rationale of this study is to compare repeatability, reproducibility and agreement of three different AS-OCT devices and Pentacam.

The investigational devices are approved biometry and keratometry devices to perform biometric/keratometric measurements preoperatively before cataract surgery. The measurements are used to calculate the needed IOL power.

Measurements with all four devices will be performed 3 times consecutively by two trained observer. The order of the observer, the order of devices as well as the eye (left/right) is randomized.

Examinations will be implemented in accordance with the approved investigational plan on subjects and includes: repeated biometry/keratometry with four different devices
Detailed Description: The rationale of this study is to compare repeatability, reproducibility and agreement of both, AS-OCT(s) and Pentacam. In our department three different AS-OCT devices and a HR Scheimpflug imaging device are currently in use for clinical routine to measure the cornea. Among refractive and anterior segment surgeons, there is no preferred and accepted method for accurate measurements of the corneal curvature. The four diagnostic tools are based on different technical and physical imaging principles and to date only limited information on their comparability exist. One advantage of ASOCT represents faster imaging speed when compared to Scheimpflug imaging. Thus, imaging misalignment, segmentation errors and defocus aberration can most likely be avoided by AS-OCT. Chen et al demonstrated that HR Scheimpflug imaging measurements of CCT were systematically higher than the measurements provided by FD AS-OCT. Further, repeatability, reproducibility and agreement of AS-OCT and Scheimpflug imaging device will be assessed during follow-up.