Viewing Study NCT05115058


Ignite Creation Date: 2025-12-25 @ 12:05 AM
Ignite Modification Date: 2025-12-25 @ 10:04 PM
Study NCT ID: NCT05115058
Status: ENROLLING_BY_INVITATION
Last Update Posted: 2024-02-20
First Post: 2021-11-05
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: A New Successful Approach for Emmetropic Presbyopic Patients Using Intrastromal Pocket With Smile Module
Sponsor: Eye Hospital Pristina Kosovo
Organization:

Study Overview

Official Title: A New Successful Approach for Emmetropic Presbyopic Patients Using Intrastromal Pocket With Smile Module
Status: ENROLLING_BY_INVITATION
Status Verified Date: 2024-02
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Presbyopia is physiological insufficiency of accommodation associated with the aging of the eye that results in progressively worsening ability to focus clearly on close objects.Though presbyopia is a normal change in our eyes as we age, it often is a significant and emotional event because it's a sign of aging that's impossible to ignore and difficult to hide.

This defect is usually corrected by using glasses with bifocal power of suitable focal lengths.

But some patients don't want to use glasses for correction. In our study purpose is to show that near vision improves and patient satisfaction increases by preparing an intrastromal pocket for emmetropic patients with near vision problems using the SMILE module.
Detailed Description: This study started at 2016 was performed in Eye Hospital Pristina in 82 eyes of 41 patients aged (40-50) with the emmetropic presbyopic complaint.VisuMax femtosecond laser created the stromal pocket with a diameter 7.60 mm and cap thickness set to 120 μm from corneal surface and with a small opening - 2 mm superior incision at 90° and side cut angle 50°. The pocket was dissected using a blunt spatula.

The patients were followed up for one year with distance, intermediate, and near visual acuity, slit lamp, corneal topography, anterior segment optical coherence tomography. Uncorrected near visual acuity at 35 cm increased from J7 to J2 in 8 eyes operated on, from J8 to J2 in 7 eyes, and from J6 to J2 in 6 eyes. Uncorrected intermediate visual acuity ranged from J4 to J5 at 70 cm, and uncorrected distance visual acuity remained binocular at 20/20. The patients reported satisfaction while reading a book, looking at the phone, and using a computer. No discomfort was observed from the lights while driving at night. We are shaping the surface of the cornea via an introstrımal pocket. We are using the SMILE module without removing the lenticule, and we are just separating the center of the cap from the top of lenticule In the short term, we have observed increases in spherical aberrations of patients. We also think that corneal shaping has an effect on the presbyopic correction. We will see and analyze the long-term effects by observing them.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: