Viewing Study NCT00392158


Ignite Creation Date: 2025-12-25 @ 12:05 AM
Ignite Modification Date: 2025-12-25 @ 10:03 PM
Study NCT ID: NCT00392158
Status: COMPLETED
Last Update Posted: 2016-09-26
First Post: 2006-10-24
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Manual Administration of Propofol-remifentanil Versus Dual Closed-loop Using Bispectral Index as the Control Variable
Sponsor: Hopital Foch
Organization:

Study Overview

Official Title: Target-controlled Infusion of Propofol and Remifentanil During General Anaesthesia Guided by the Index Bispectral: Comparison Between Manual Perfusion and Automated Perfusion
Status: COMPLETED
Status Verified Date: 2016-09
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: To compare manual administration of propofol and remifentanil and dual closed-loop using bispectral index as the control variable during anesthesia
Detailed Description: The Bispectral Index (BIS) is an electroencephalogram-derived measure of anesthetic depth. A closed-loop anesthesia system can be built using BIS as the control variable, a proportional-integral-differential control algorithm, and a propofol target-controlled infusion system as the control actuator. Recent studies have shown that such system is able to provide clinically adequate anesthesia. We hypothesized that BIS can also indicate the adequacy of analgesia and therefore built a combined closed-loop anesthesia system using BIS as the control variable, two proportional-integral-differential control algorithms, a propofol and a remifentanil target-controlled infusion systems as the control actuators. In preparation for a large multi-center control trial, we propose a prospective randomized study to evaluate the effectiveness of such a closed-loop anesthesia system. Two groups of patients are compared: one in which propofol and remifentanil are administered by the anesthesiologist using target-controlled infusion systems, and one in which propofol and remifentanil are administered automatically by the combined closed-loop anesthesia system. In both groups, the goal is to maintain BIS between 40 and 60, the recommended range during anesthesia by the manufacturer. We expect the combined closed-loop anesthesia system group to do similar or better.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: