Viewing Study NCT06962358


Ignite Creation Date: 2025-12-25 @ 12:00 AM
Ignite Modification Date: 2026-01-01 @ 5:12 PM
Study NCT ID: NCT06962358
Status: COMPLETED
Last Update Posted: 2025-05-08
First Post: 2025-04-23
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Three Years Radiographic Evaluation of Different Implant Retained Complete Over Denture Attachments (In Vivo Study)
Sponsor: Tanta University
Organization:

Study Overview

Official Title: Three Years Radiographic Evaluation of Different Implant Retained Complete Over Denture Attachments (In Vivo Study)
Status: COMPLETED
Status Verified Date: 2025-04
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Abstract: Treatment of completely edentulous patients with implant over dentures became a common treatment modality that greatly improves the patient's quality of life. AIM: The aim of this randomized clinical trial was to evaluate three different types of implants retained over denture attachment for three years of fellow up. Material and Methods: In a randomized prospective trial 24 completely edentulous patients of age ranged from 50-65 years were carefully selected. The patients were divided into 3 groups group A patients of implant retained over denture with telescopic attachment, Group B patients of implant retained over denture with locator attachment and Group C implant retained over denture with ball and socket attachment, over three years radiographic evaluation was carried out
Detailed Description: According to Zarb el al., 15acrylic denture was constructed first Then a radiographic template was prepared16. Two separate CBCT (dual scan technique) images of the radiographic stent were acquired using a CAT FLX V17, Nc 28273, Kavo, Charlotte, USA. data acquired from DICOM Superimposition in implant planning software (In2guide by 3DIEMME) ® allowed for precise evaluation of implant sites in edentulous regions (virtual placement of implants considering the relation to anatomical structures and prosthetic requirements) since the prosthesis could be seen over the accessible bone architecture. , Two implants positioned vertically (Narrow sky 3512, bredent, Germany) for all patients Two healing abutments were screwed into place after the canine regions were bilaterally implanted with narrow plate forms measuring 3.5 mm in diameter and 12 mm in length. The denture was put back into place with silicon soft lining materials after 7 days of healing, and it was meant to be worn for one month. Patients who got telescopic attachments for their implant-retained overdentures were randomly assigned to one of three groups of eight patients each based on GA. (GB): the individual who got an implant-retained overdenture that has a locator attachment (Gc): the individual who got an implant-retained overdenture that has a ball and socket fixation

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: