Viewing Study NCT00515151


Ignite Creation Date: 2025-12-24 @ 11:56 PM
Ignite Modification Date: 2025-12-25 @ 9:53 PM
Study NCT ID: NCT00515151
Status: COMPLETED
Last Update Posted: 2007-08-13
First Post: 2007-08-10
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Prevention of Catheter-Associated Infection With the Skin Disinfectant Octenidine Dihydrochloride
Sponsor: University Hospital Freiburg
Organization:

Study Overview

Official Title: Skin Disinfection With Octenidine Dihydrochloride for the Prevention of Catheter-Associated Infections - A Double-Blind, Randomized, Controlled Trial
Status: COMPLETED
Status Verified Date: 2007-08
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Health-care-acquired infections are of tremendous importance for patients, especially catheter-associated infections. More than 40% of all bloodstream infections are associated with central venous catheters (CVC; catheters which are inserted into a large vein near the heart). Of all patients that acquire such an infection 1% to 5% die as a result from it. The insertion site is the main source of contamination and infection. In general, bacteria of the skin are the cause of infection, especially in short-term CVCs (10-14 days). Therefore it is necessary to efficiently disinfect the skin for the preparation and care of CVC insertion sites. Several substances are used for disinfection. Alcohol-based disinfectants are mainly used in Central Europe, other preparations contain povidine-iodine or chlorhexidine. Alcoholic disinfectants have a rapid initial effect, chlorhexidine shows an additional remanent (longer lasting) effect. A further substance, octenidine dihydrochloride, also demonstrated a remanent effect in a pilot study with neurosurgical patients. The purpose of our study is to compare an alcohol-based disinfectant containing octenidine dihydrochloride with a pure alcoholic disinfectant regarding efficacy and tolerability in patients receiving a CVC for a minimum of 5 days.
Detailed Description: Catheter-associated infections are one of the most eminent healthcare acquired infections. More than 40% of all bloodstream infections are associated with a central venous catheter (CVC)and between 1% and 5% of the affected patients die as a direct consequence of this infection. The most important microorganisms are gram-positive cocci (S. aureus, S. epidermidis). In intensive care units gram-negative microorganisms such as pseudomonas, acinetobacter and candida spp. are more frequent. The insertion site is the main source of contamination and infection in short-term CVCs (10-14 days. In this case the infection is caused by migration of microorganisms along the outside of the catheter. Contamination of the hub due to frequent manipulation is usually the source of infection in long-term CVCs. In this case the infection occurs intraluminally. An effective skin disinfection is the main measure of prevention before insertion of a CVC. The aim of this measure is the elimination of transient and the reduction of resident microorganisms around the insertion site. To achieve this, disinfectants on the basis of alcohol, povidone-iodine or chlorhexidine are applied. Alcohol-based disinfectants are preferred in Central Europe because of their rapid initial effect and broad microbiological spectrum. Chlorhexidine and povidone-Iodine in contrast to alcoholic disinfectants have a remanent effect which reduces regrowth of microorganisms beyond the immediate initial effect. To which extent remanent substances reduce colonization of the CVC extraluminally or the CVC-tip is still being disputed. In an earlier clinical trial a residual or remanent effect of 0.1% octenidine combined with propanol in microbial skin decontamination over a 24h period was shown in neurosurgical patients receiving a central line (CVC or peripherally inserted central catheter). The objective of this study is therefore to evaluate further the preventive impact and tolerability of a commercially available, alcohol-based antiseptic solution containing octenidine for the preparation and care of CVC insertion sites in a clinical setting in comparison with the results given by an alcoholic solution alone.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: