Brief Title: GE Healthcare VolumeRAD Lung Nodule Detection Study
Sponsor: American College of Radiology - Image Metrix
Organization:

Study Overview

Official Title: GE Healthcare VolumeRAD Lung Nodule Detection Study
Status: COMPLETED
Status Verified Date: 2013-07
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: To perform a multiple reader, multiple case (MRMC) observer study assessing the detection performance of VolumeRAD tomosynthesis of the chest in detecting lung nodules.
Detailed Description: Digital tomosynthesis is a form of limited angle tomography that creates a series of section images using a conventional x-ray tube and generator, a digital detector, and appropriate reconstruction software. It creates section images from a series of projection images acquired as the x-ray tube moves along a prescribed path. Because tomosynthesis can minimize the visual presence of overlying anatomy - the ribs, for example - it has the potential to improve the detection of lesions such as pulmonary nodules when compared with conventional chest radiography.

The primary aim of this study is to determine whether the use of VolumeRAD tomosynthesis, in addition to CxR, increases physician accuracy in the detection of lung nodules between 3mm and 20mm in diameter when compared to conventional posterior-anterior (PA) and lateral (LAT) chest radiography (CxR). This aim will be addressed by measuring free-response performance of experienced (with VolumeRAD), blinded expert readers' detection performance. Specifically, we will compare detection performance, as measured by the area under the alternative free response receiver operating characteristic (AFROC) curve, among readers viewing PA and LAT chest X-rays versus VolumeRAD tomosynthesis. The nodule will be the unit of analysis.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
GE 2901 None None View