Viewing Study NCT03837951


Ignite Creation Date: 2025-12-24 @ 11:51 PM
Ignite Modification Date: 2026-01-05 @ 5:15 AM
Study NCT ID: NCT03837951
Status: COMPLETED
Last Update Posted: 2020-03-31
First Post: 2019-02-08
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Figure-of-Eight Hand, Volumetric Measurements and Reliability in Clinic With Hand Injured Patients
Sponsor: University of Massachusetts, Lowell
Organization:

Study Overview

Official Title: Comparison of Figure-of-Eight Hand Measurements to Standard Volumetric Measurements and Its Reliability Within a Clinical Setting With Hand Injured Patients
Status: COMPLETED
Status Verified Date: 2020-03
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: This study determined the intra-rater and inter-rater reliability of the Figure-of-Eight method on healthy hands, and compared the figure-of-eight measurements to the gold standard volumetric measurements. Part B of the study conducted in a clinic, assessed the intra-rater reliability and inter-rater reliability on both hands of patients with hand injuries.
Detailed Description: Edema is the retention of fluid in the intracellular spaces, which is common in inflammatory condition such as traumatic injury and post surgical conditions. Edema in the hand and wrist can result in detrimental physiological changes which decrease the range of motion of joint and limit the overall functional capacity and dexterity of the hand. The gold standard Volumetric measurements are reliable for measuring edema changes in upper extremity. Using volumeters can be cumbersome in a busy clinic. Figure-of-eight measurements using a tape measure on the wrist and hand is an easy way to measure edema and can capture the accumulation in the dorsal hand that circumferential tape measurements do not capture. This study was performed in two parts. Part A determined the intra-rater and inter-rater reliability of the Figure-of-Eight method on healthy hands, and compared the figure-of-eight measurements to the gold standard volumetric measurements. No study other study has compared right and left hands. Part B of the study was conducted in a clinic to assess the intra-rater reliability and inter-rater reliability on both hands of patients with hand injuries.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: