Viewing Study NCT04500912


Ignite Creation Date: 2025-12-26 @ 10:19 PM
Ignite Modification Date: 2025-12-26 @ 10:19 PM
Study NCT ID: NCT04500912
Status: COMPLETED
Last Update Posted: 2023-09-15
First Post: 2020-07-26
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Comparison of the Supraflex Cruz 60 Micron Versus the Ultimaster Tansei 80 Micron in HBR PCI Population
Sponsor: Pieter C.Smits
Organization:

Study Overview

Official Title: Comparison of the Supraflex Cruz 60 Micron Stent Strut Versus the Ultimaster Tansei 80 Micron Stent Strut in High Bleeding Risk PCI Population
Status: COMPLETED
Status Verified Date: 2023-09
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The study compares the outcome of the ultrathin stent strut Supraflex Cruz stent to the thin stent strut Ultimaster Tansei stent in a PCI population at high risk for bleeding (HBR).
Detailed Description: Study design: An Investigator-initiated, multi-center, randomized clinical trial in HBR patients receiving PCI with Supraflex Cruz or Ultimaster Tansei stents

Study population: 2 x 368 (736) patients, who undergo a PCI and are at high risk for bleeding (HBR).

Intervention: Patients are treated according to the randomized regimen at index PCI and at planned staged procedures. Either with the ultrathin stent strut Supraflex Cruz stent to the thin stent strut Ultimaster Tansei stent

DAPT treatment (combination and duration) is according to the Guidelines of the European Society of Cardiology for Myocardial Revascularization.

Follow-up is scheduled at 1 month, 6 months and 12 months post index PCI procedure.

Primary study parameters/outcome of the study:

The primary endpoint Net Adverse Clinical Endpoints (NACE) defined as a composite of cardiovascular death, myocardial infarction, target vessel revascularization, stroke and bleeding events defined as BARC 3 or 5 at 12 months follow-up after the index PCI.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: